FJFaisal R. Jahangiri

Faisal R. Jahangiri

*This is an algorithmically generated author record based on publicly available information.

Faisal R. Jahangiri has a total of 166 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Triggered electromyography-guided progressive fascicular subdivision to identify a bilaterally tEMG-silent interval in conjoined twin spinal cord separation: a dual-configuration case series

    by Vizmary J. Montes-Peña, Fayez AlEnazy, Abdullah AlBishi, Moutasem Azzubi, Tariq Aljared, Pedro Álvarez-Díaz, Faisal R. Jahangiri

    Surgical separation of conjoined twins with fused caudal spinal cords requires identification of a safe neural cleavage plane, yet anatomical boundaries are often indistinct. Triggered electromyography (tEMG) has been used to determine nerve root ownership, and iterative subdivision with sequential stimulation has been reported in pygopagus twins, but the sequence and its endpoint have not been standardized. This study describes a tEMG-guided progressive fascicular subdivision approach to identify a bilaterally tEMG-silent interval in two conjoined twin configurations. We monitored two cases (pygopagus and ischiopagus) using multimodal intraoperative neurophysiological monitoring, including tEMG, transcranial motor evoked potentials, somatosensory evoked potentials, and free-running electromyography. A dual-twin color-coded electrode configuration enabled simultaneous independent mapping of both nervous systems. Progressive fascicular subdivision with re-stimulation of each bundle was performed until a bilaterally tEMG-silent interval was identified. Case 1 involved pygopagus twins with a fused conus medullaris at S2. Case 2 involved ischiopagus twins with syringomyelia involving both spinal cords and an anterior sacral meningocele. In both cases, progressive fascicular subdivision identified a bilaterally tEMG-silent interval, which guided microsurgical separation. Motor function and anal tone were unchanged at 6-month follow-up. Triggered electromyography-guided progressive fascicular subdivision identified a bilaterally tEMG-silent interval in both pygopagus and ischiopagus configurations, including one with complex intrinsic spinal cord pathology. This interval reflects absence of detectable somatic motor activation in the monitored muscles and does not exclude sensory or autonomic fibers; its value as an intraoperative reference requires validation in larger series.

  • Open Access

    Sequential intraoperative protocol to improve bulbocavernosus reflex monitorability during pediatric spinal surgery

    by Vizmary J. Montes-Peña, Pedro Álvarez-Díaz, Wael A. AlShaya, Samir O. AlSayegh, Sami AlEissa, Fayez AlEnazy, Atheer Alamri, Faisal R. Jahangiri


  • Open Access

    Threshold-guided optimization of transcranial electrical stimulation parameters for motor evoked potential monitoring in pediatric spinal surgery

    by Vizmary J. Montes Peña, Fayez AlEnazy, Abdullah AlBishi, Samir O. AlSayegh, Sami AlEissa, Wael A. AlShaya, Moutasem Azzubi, Faisal R. Jahangiri

    Transcranial electrical stimulation motor evoked potential (TES-MEP) monitoring during pediatric spinal surgery is technically challenging due to developmental corticospinal physiology. We quantified the effects of electrode montage, stimulation pattern, and interstimulus interval (ISI) on motor threshold (MT) to define a practical optimization protocol for pediatric neuromonitoring. Eighty-one pediatric patients (0.5–17 years) undergoing spinal or spinal cord surgery were analyzed using a prospective within-patient design. Effects of montage and stimulation pattern were assessed with repeated-measures ANOVA. ISI modulation (2, 3, 4 ms) was evaluated within the linked quadripolar montage with double-train stimulation (LQP-DTS) in patients without floor effect (n = 65). Multivariable regression identified determinants of baseline MT, ISI responsiveness, and pulse escalation. Montage and stimulation pattern exerted large independent effects on MT (η2p = 0.986 and 0.969; both p < 0.001). LQP-DTS reduced mean MT by 77.8 V (95% CI 76.1–79.6) compared with C1–C2 STS and produced the lowest threshold in all patients. ISI significantly modulated MT (η2p = 0.868, p < 0.001), with a 17.35 V increase at 2 ms and a 3.46 V decrease at 4 ms relative to 3 ms. Younger age and preoperative motor deficit independently predicted higher baseline MT (R2 = 0.699, p < 0.001). Baseline MT predicted ISI responsiveness and pulse escalation (AUC 0.917–0.918). Pediatric TES-MEP thresholds follow a reproducible physiological hierarchy. Optimization using LQP-DTS at ISI 3 ms with threshold-guided adjustment reduces stimulation requirements and supports reliable corticospinal monitoring during pediatric spinal surgery. The online version contains supplementary material available at 10.1007/s00381-026-07339-0.


  • Open Access

    Intraoperative Testing During the Mapping of the Language Cortex

    by Shabab S. Kabir, Faisal R. Jahangiri, Callista Rinesmith, Cristobal S. Vilches, Swati Chakarvarty

    The Ethics Statement and Conflict of Interest Disclosures section has been updated to disclose the following: Financial relationships: Shadab S. Kabir, Faisal R. Jahangiri, and Swati Chakarvarti declare(s) employment from Global Innervation LLC. Global Innervation LLC promotes and provides intraoperative neurophysiological monitoring.

  • Response to ASNM intraoperative SSEP position statement

    by J. Richard Toleikis, Christopher Pace, Faisal R. Jahangiri, Laura B. Hemmer, Sandra C. Toleikis

    This correspondence is in response to Dr. David Allison’s comments to the Editor, regarding the American Society of Neurophysiological Monitoring’s (ASNM) updated intraoperative somatosensory evoked potential (SEP) monitoring position statement.

  • Top Cited Papers
    Open Access

    Intraoperative somatosensory evoked potential (SEP) monitoring: an updated position statement by the American Society of Neurophysiological Monitoring

    by J. Richard Toleikis, Christopher Pace, Faisal R. Jahangiri, Laura B. Hemmer, Sandra C. Toleikis

    Somatosensory evoked potentials (SEPs) are used to assess the functional status of somatosensory pathways during surgical procedures and can help protect patients’ neurological integrity intraoperatively. This is a position statement on intraoperative SEP monitoring from the American Society of Neurophysiological Monitoring (ASNM) and updates prior ASNM position statements on SEPs from the years 2005 and 2010. This position statement is endorsed by ASNM and serves as an educational service to the neurophysiological community on the recommended use of SEPs as a neurophysiological monitoring tool. It presents the rationale for SEP utilization and its clinical applications. It also covers the relevant anatomy, technical methodology for setup and signal acquisition, signal interpretation, anesthesia and physiological considerations, and documentation and credentialing requirements to optimize SEP monitoring to aid in protecting the nervous system during surgery.


  • Open Access

    Intraoperative Testing During the Mapping of the Language Cortex

    by Shabab S Kabir, Faisal R Jahangiri, Callista Rinesmith, Cristobal S Vilches, Swati Chakarvarty

    Intracranial lesions, particularly in the language-eloquent areas of the brain, can affect one's speaking ability. Despite advances in surgery, the excision of these lesions can be challenging. Intraoperative neurophysiological monitoring (IONM) during awake craniotomies can help identify language-eloquent areas and minimize postoperative impairments. Preoperative language testing is performed to establish a baseline before intraoperative language testing. This involves subjecting patients to predetermined tasks in the operating room to evaluate their phonological, semantic, and syntactic capabilities. The current state and future directions of intraoperative language testing procedures are discussed in this paper. The most common intraoperative tasks are counting and picture naming. However, some experts recommend utilizing more nuanced tasks that involve regions affected by infrequently occurring tumor patterns. Low-frequency bipolar Penfield stimulation is optimal for language mapping. Exception cases are discussed where awake craniotomies are not feasible. When dealing with multilingual patients, the patient's age of learning and skill level can be accounted for in terms of making informed task choices and mapping techniques to avoid any damage to language areas.


  • Open Access

    Scoliosis Corrective Surgery With Continuous Intraoperative Neurophysiological Monitoring (IONM)

    by Faisal R. Jahangiri, Rafia H. Jahangiri, Hooria Asad, Laila Farooq, Wadana H. Khattak

    Scoliosis is a spine deformity that presents as Cobb’s angle greater than 10 degrees. Pedicle screw placement can be employed in scoliosis corrective procedures but poses a danger of disrupting the motor and sensory pathways by injuries to the nerves, spinal cord, and vasculature. Occasionally traction weight is applied before the instrumentation for correction. This correction weight may cause spinal cord functional compromise and may result in postoperative paresis or paralysis. A 10-year-old female patient with Cobb's angle of 120 degrees was scheduled for scoliosis correction surgery. A multimodality intraoperative neurophysiological monitoring (IONM) approach was designed with somatosensory evoked potentials (SSEPs), transcranial electrical motor evoked potentials (TCeMEPs), spontaneous electromyography (s-EMG), triggered electromyography (t-EMG) and train of four (TOF). In this patient, after placing the pedicle screw, TCeMEP changes were immediately identified and reported to the surgeon in the left lower extremity followed by both lower extremities. The surgeon immediately asked the anesthesiologist to remove 25 pounds of traction weight from the head and increase the mean arterial pressure. TCeMEP responses returned to the baselines immediately. Later during the surgery, left arm SSEP changes were also identified, which returned to normal on the repositioning of the arm. Multimodal IONM has the benefit of monitoring the sensory and motor functions of the spinal cord and nerve function at risk of damage during the procedure. The utilization of IONM in this spinal cord correction surgery helped to detect and timely reverse nerve injuries. We strongly recommend utilizing multimodality IONM during scoliosis correction procedures as a standard of care to minimize postoperative neurological deficits.


  • Open Access

    Deep Brain Stimulation and Microelectrode Recording for the Treatment of Parkinson’s Disease

    by Joshua Fejeran, Frank Salazar, Cesia M. Alvarez, Faisal R. Jahangiri

    Parkinson’s disease (PD) is a neurological disorder in which nigrostriatal pathways involving the basal ganglia experience a decrease in neural activity regarding dopaminergic neurons. PD symptoms, such as muscle stiffness and involuntary tremors, have an adverse impact on the daily lives of those affected. Current medical treatments seek to decrease the severity of these symptoms. Deep brain stimulation (DBS) has become the preferred safe, and reliable treatment approach. DBS involves implanting microelectrodes into subcortical areas that produce electrical impulses directly to high populations of dopaminergic neurons. The most common targets are the subthalamic nucleus (STN), and the basal ganglia's globus pallidus pars interna (GPi). Research studies suggest that DBS of the STN may cause a significant reduction in the daily dose of L-DOPA compared to DBS of the GPi. DBS of the STN has suggested that there may be sweet spots within the STN that provide hyper-direct cortical connectivity pathways to the primary motor cortex (M1), supplementary motor area (SMA), and prefrontal cortex (PFC). In addition, the pedunculopontine nucleus (PPN) may be a new target for DBS that helps treat locomotion problems associated with gait and posture. Both microelectrode recording (MER) and magnetic resonance imaging (MRI) are used to ensure electrode placement accuracy. Using MER, stimulation of the STN at high frequencies (140<) decreased oscillatory neuronal firing by 67%. This paper investigates methods of intraoperative neuromonitoring during DBS as a form of PD treatment.