Maho Kaminaga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Maho Kaminaga has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Tadashi Ishida
Department of Mechanical Engineering, Institute of Science Tokyo, 4529 Nagatsuta-cho, Midori-ku, Yokohama, Kanagawa 226-8501, Japan
4 shared publications - Toru Omata
Department of Mechanical Engineering, School of Engineering, Tokyo Institute of Technology, Kanagawa 226-8503, Japan
4 shared publications - Shinae Kizaka-Kondoh
School of Life Science and Technology, Tokyo Institute of Technology, Yokohama, Japan
3 shared publications - Tetsuya Kadonosono
School of Life Science and Technology, Tokyo Institute of Technology, Yokohama, Japan
2 shared publications - Takahiro Kuchimaru
Jichi Medical University
1 shared publication - Takuya Shimamoto
Department of Mechano-Micro Engineering, Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, Kanagawa 226-8503, Japan
1 shared publication
Latest Publications
- Open Access
- 11 February 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (2) , 116
Microfluidic High-Migratory Cell Collector Suppressing Artifacts Caused by Microstructures
The small number of high-migratory cancer cells in a cell population make studies on high-migratory cancer cells difficult. For the development of migration assays for such cancer cells, several microfluidic devices have been developed. However, they measure migration that is influenced by microstructures and they collect not only high-migratory cells, but also surrounding cells. In order to find high-migratory cells in cell populations while suppressing artifacts and to collect these cells while minimizing damages, we developed a microfluidic high-migratory cell collector with the ability to sort cancer cells according to cellular migration and mechanical detachment. High-migratory cancer cells travel further from the starting line when all of the cells are seeded on the same starting line. The high-migratory cells are detached using a stretch of cell adhesive surface using a water-driven balloon actuator. Using this cell collector, we selected high-migratory HeLa cells that migrated about 100 μm in 12 h and collected the cells.
- 11 February 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (2) , 116
Open AccessMicrofluidic High-Migratory Cell Collector Suppressing Artifacts Caused by Microstructures
The small number of high-migratory cancer cells in a cell population make studies on high-migratory cancer cells difficult. For the development of migration assays for such cancer cells, several microfluidic devices have been developed. However, they measure migration that is influenced by microstructures and they collect not only high-migratory cells, but also surrounding cells. In order to find high-migratory cells in cell populations while suppressing artifacts and to collect these cells while minimizing damages, we developed a microfluidic high-migratory cell collector with the ability to sort cancer cells according to cellular migration and mechanical detachment. High-migratory cancer cells travel further from the starting line when all of the cells are seeded on the same starting line. The high-migratory cells are detached using a stretch of cell adhesive surface using a water-driven balloon actuator. Using this cell collector, we selected high-migratory HeLa cells that migrated about 100 μm in 12 h and collected the cells.
- Open Access
- 9 January 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (1) , 41
Microfluidic Device for Screening for Target Cell-Specific Binding Molecules by Using Adherent Cells
This paper proposes a microfluidic device for screening molecules such as aptamers, antibodies, proteins, etc. for target cell-specific binding molecules. The discovery of cancer cell-specific binding molecules was the goal of this study. Its functions include filtering non-target cell-binding molecules, trapping molecules on the surface of target cells, washing away unbound molecules, and collecting target cell-specific binding molecules from target cells. These functions were effectively implemented by using our previously developed micro pillar arrays for cell homogeneous dispersion and pneumatic microvalves for tall microchannels. The device was also equipped with serially connected filter chambers in which non-target cells were cultured to reduce the molecules binding to non-target cells as much as possible. We evaluated the performance of the device using cancer cell lines (N87 cells as target cells and HeLa cells as non-target cells) and two fluorescent dye-labeled antibodies: Anti-human epidermal growth factor receptor 2 (anti-HER2) antibody that binds to target cells and anti-integrin antibody that binds to non-target cells. The results showed that the device could reduce anti-integrin antibodies to the detection limit of fluorescent measurement and collect anti-HER2 antibodies from the target cells.
- 9 January 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (1) , 41
Open AccessMicrofluidic Device for Screening for Target Cell-Specific Binding Molecules by Using Adherent Cells
This paper proposes a microfluidic device for screening molecules such as aptamers, antibodies, proteins, etc. for target cell-specific binding molecules. The discovery of cancer cell-specific binding molecules was the goal of this study. Its functions include filtering non-target cell-binding molecules, trapping molecules on the surface of target cells, washing away unbound molecules, and collecting target cell-specific binding molecules from target cells. These functions were effectively implemented by using our previously developed micro pillar arrays for cell homogeneous dispersion and pneumatic microvalves for tall microchannels. The device was also equipped with serially connected filter chambers in which non-target cells were cultured to reduce the molecules binding to non-target cells as much as possible. We evaluated the performance of the device using cancer cell lines (N87 cells as target cells and HeLa cells as non-target cells) and two fluorescent dye-labeled antibodies: Anti-human epidermal growth factor receptor 2 (anti-HER2) antibody that binds to target cells and anti-integrin antibody that binds to non-target cells. The results showed that the device could reduce anti-integrin antibodies to the detection limit of fluorescent measurement and collect anti-HER2 antibodies from the target cells.
- Open Access
- 9 December 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (12) , 224
Fabrication of Pneumatic Microvalve for Tall Microchannel Using Inclined Lithography
We used inclined lithography to fabricate a pneumatic microvalve for tall microchannels such as those used to convey large cells. The pneumatic microvalve consists of three layers. The upper layer is the actual liquid microchannel, which has a parallelogram-shaped cross section of width 500 μm, height 100 μm, and an acute angle of 53.6°. The lower layer is a pneumatic microchannel that functions as an actuator, and the middle layer is a thin polydimethylsiloxane membrane between the upper and lower layers. The operation of the pneumatic microchannel actuator causes the thin membrane to bend, resulting in the bending of the liquid microchannel and its closure. It was confirmed that the closure of the liquid microchannel completely stopped the flow of the HeLa cell suspension that was used to demonstrate the operation of the microvalve. The HeLa cells that passed through the microchannel were also observed to retain their proliferation and morphological properties.
- 9 December 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (12) , 224
Open AccessFabrication of Pneumatic Microvalve for Tall Microchannel Using Inclined Lithography
We used inclined lithography to fabricate a pneumatic microvalve for tall microchannels such as those used to convey large cells. The pneumatic microvalve consists of three layers. The upper layer is the actual liquid microchannel, which has a parallelogram-shaped cross section of width 500 μm, height 100 μm, and an acute angle of 53.6°. The lower layer is a pneumatic microchannel that functions as an actuator, and the middle layer is a thin polydimethylsiloxane membrane between the upper and lower layers. The operation of the pneumatic microchannel actuator causes the thin membrane to bend, resulting in the bending of the liquid microchannel and its closure. It was confirmed that the closure of the liquid microchannel completely stopped the flow of the HeLa cell suspension that was used to demonstrate the operation of the microvalve. The HeLa cells that passed through the microchannel were also observed to retain their proliferation and morphological properties.
- Open Access
- 1 April 2015
- Published by MDPI AG in Micromachines
- Vol. 6 (4) , 409-422
Uniform Cell Distribution Achieved by Using Cell Deformation in a Micropillar Array
The uniform dispersion of cells in a microchamber is important to reproduce results in cellular research. However, achieving this is difficult owing to the laminar flow caused by the small dimensions of such a chamber. In this study, we propose a technique to achieve a uniform distribution of cells using a micropillar array inside a microchamber. The cells deform when they pass through a gap between the micropillars. The deformation causes a repetitive clog-and-release process of cells at the gaps between the micropillars. The micropillar array generates random flow inside the microchamber, resulting in the uniform distribution of the cells via cell accumulation. In the experiment, the distribution of cells in the microchamber with the micropillar array is uniform from end to end, whereas that in the microchamber without the micropillar array is centered. The deviation of the cell distribution from the ideally uniform distribution in the microchamber with the micropillar array is suppressed by 63% compared with that in the microchamber without the micropillar array. The doubling time of the cells passed through the micropillar array did not change relative to that of normal N87 cells. This technique will be helpful for reproducing results in cellular research at the micro scale or for those using microfluidic devices.
- 1 April 2015
- Published by MDPI AG in Micromachines
- Vol. 6 (4) , 409-422
Open AccessUniform Cell Distribution Achieved by Using Cell Deformation in a Micropillar Array
The uniform dispersion of cells in a microchamber is important to reproduce results in cellular research. However, achieving this is difficult owing to the laminar flow caused by the small dimensions of such a chamber. In this study, we propose a technique to achieve a uniform distribution of cells using a micropillar array inside a microchamber. The cells deform when they pass through a gap between the micropillars. The deformation causes a repetitive clog-and-release process of cells at the gaps between the micropillars. The micropillar array generates random flow inside the microchamber, resulting in the uniform distribution of the cells via cell accumulation. In the experiment, the distribution of cells in the microchamber with the micropillar array is uniform from end to end, whereas that in the microchamber without the micropillar array is centered. The deviation of the cell distribution from the ideally uniform distribution in the microchamber with the micropillar array is suppressed by 63% compared with that in the microchamber without the micropillar array. The doubling time of the cells passed through the micropillar array did not change relative to that of normal N87 cells. This technique will be helpful for reproducing results in cellular research at the micro scale or for those using microfluidic devices.