Andrea Magistrelli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrea Magistrelli has a total of 99 co-authors. Here are the top co-authors by number of shared publications:
- Paolo Tomà
Department of Imaging, Bambino Gesù Children’s Hospital, IRCCS, 00165 Rome, Italy
9 shared publications Paolo Belli
Catholic University School of Medicine, Policlinico “Agostino Gemelli
8 shared publications- Melania Costantini
Istituto di Radiologia, Università Cattolica del S. Cuore, Policlinico A. Gemelli, Largo A. Gemelli 8, 00168 Roma, Italy
7 shared publications Giovanna Pastore
5 shared publications- Gianluca Franceschini
Breast Surgery Unit, Department of Woman and Child’s Health and Public Health Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
4 shared publications Vittorio Cannatà
Servizio Prevenzione e Protezione/Fisica Sanitaria, Ospedale Pediatrico Bambino Gesù, IRCCS, Rome, Italy
4 shared publications
Latest Publications
- Open Access
- 26 August 2026
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 70 (7)
Evaluation of the additional occupational risk for workers with orthopedic implants in MRI settings
Objective: To provide quantitative information that can aid the relevant authority in deciding whether workers with metallic nonferromagnetic orthopedic implants can work in proximity to magnetic resonance imaging (MRI) scanners, including when the exam is being performed. Methods: Virtual experiments in which the exposure of workers with and without prostheses is evaluated through numerical simulation of realistic human models, with reference to 4 physical effects: radiofrequency (RF)-induced heating, gradient-induced heating, gradient-induced peripheral nerve stimulation, and mechanical actions related to the Lenz effect. Results: In the presence of the considered implants, the extent of RF-induced heating and of the electric field responsible for peripheral nerve stimulation is low and comparable to what is observed without the prostheses. The extent of gradient-induced heating and Lenz effect, which occur only in the presence of implants, is minimal. Conclusion: As long as the body of the worker with passive non-ferromagnetic orthopedic implants remains outside the MRI scanner, the incremental risk posed by the presence of the implants is negligible. The Lenz effect is weak even if the part of the worker's body with an implant enters the scanner bore.
- 26 August 2026
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 70 (7)
Open AccessEvaluation of the additional occupational risk for workers with orthopedic implants in MRI settings
Objective: To provide quantitative information that can aid the relevant authority in deciding whether workers with metallic nonferromagnetic orthopedic implants can work in proximity to magnetic resonance imaging (MRI) scanners, including when the exam is being performed. Methods: Virtual experiments in which the exposure of workers with and without prostheses is evaluated through numerical simulation of realistic human models, with reference to 4 physical effects: radiofrequency (RF)-induced heating, gradient-induced heating, gradient-induced peripheral nerve stimulation, and mechanical actions related to the Lenz effect. Results: In the presence of the considered implants, the extent of RF-induced heating and of the electric field responsible for peripheral nerve stimulation is low and comparable to what is observed without the prostheses. The extent of gradient-induced heating and Lenz effect, which occur only in the presence of implants, is minimal. Conclusion: As long as the body of the worker with passive non-ferromagnetic orthopedic implants remains outside the MRI scanner, the incremental risk posed by the presence of the implants is negligible. The Lenz effect is weak even if the part of the worker's body with an implant enters the scanner bore.
- Open Access
- 25 July 2026
- Published by Elsevier in Physica Medica
- Vol. 148, 105906
Artificial Intelligence for radiation protection in medical imaging and radiotherapy: A perspective from the AI Working Party of ICRP Committee 3
- 25 July 2026
- Published by Elsevier in Physica Medica
- Vol. 148, 105906
Open AccessArtificial Intelligence for radiation protection in medical imaging and radiotherapy: A perspective from the AI Working Party of ICRP Committee 3
- 21 April 2026
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 46 (2)
Direct and indirect assessment: comparison of different methods to estimate staff equivalent dose to the lens during different interventional procedures
The reduction of the annual equivalent dose limit to the lens of the eye from 150 to 20 mSv has increased the need for reliable assessment of occupational eye lens exposure, particularly in interventional radiology. Lens absorbed dose is commonly evaluated either using a dosimeter near the eye or indirectly using chest dosimeter readings. Although the indirect approach is well established in interventional cardiology, its validity for procedures with different exposure geometries remains uncertain. This study evaluated the agreement between direct and indirect estimates of lens equivalent dose in haemodynamic, electrophysiological and gastroenterological procedures. Forty-one physicians were monitored using thermoluminescent dosimeters placed close to the eye and on the chest above the lead apron. Direct lens doses were compared with indirect estimates derived from chest dosimeter. Agreement was assessed using linear fitting, Pearson’s correlation coefficients and analysis of variance. A total of 449 valid dosimetric pairs were analysed. A statistically significant correlation between direct and indirect lens dose estimates was observed for haemodynamic and electrophysiological procedures. The indirect lens dose estimates provided conservative estimates in approximately 80% of cases and never resulted in exceedance of the 20 mSv annual dose limit. In contrast, no significant correlation was found for ERCP (Endoscopic Retrograde CholangioPancreatography) procedures, where indirect estimates frequently underestimated lens dose due to non-frontal exposure geometry. These findings confirm that reliable and conservative assessment of eye lens dose estimates in interventional cardiology is possible when chest doses are well below regulatory limits. However, caution is required when extending its use to non-cardiac procedures, where procedure-specific exposure conditions may compromise the reliability of lens dose estimates.
- 21 April 2026
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 46 (2)
Direct and indirect assessment: comparison of different methods to estimate staff equivalent dose to the lens during different interventional procedures
The reduction of the annual equivalent dose limit to the lens of the eye from 150 to 20 mSv has increased the need for reliable assessment of occupational eye lens exposure, particularly in interventional radiology. Lens absorbed dose is commonly evaluated either using a dosimeter near the eye or indirectly using chest dosimeter readings. Although the indirect approach is well established in interventional cardiology, its validity for procedures with different exposure geometries remains uncertain. This study evaluated the agreement between direct and indirect estimates of lens equivalent dose in haemodynamic, electrophysiological and gastroenterological procedures. Forty-one physicians were monitored using thermoluminescent dosimeters placed close to the eye and on the chest above the lead apron. Direct lens doses were compared with indirect estimates derived from chest dosimeter. Agreement was assessed using linear fitting, Pearson’s correlation coefficients and analysis of variance. A total of 449 valid dosimetric pairs were analysed. A statistically significant correlation between direct and indirect lens dose estimates was observed for haemodynamic and electrophysiological procedures. The indirect lens dose estimates provided conservative estimates in approximately 80% of cases and never resulted in exceedance of the 20 mSv annual dose limit. In contrast, no significant correlation was found for ERCP (Endoscopic Retrograde CholangioPancreatography) procedures, where indirect estimates frequently underestimated lens dose due to non-frontal exposure geometry. These findings confirm that reliable and conservative assessment of eye lens dose estimates in interventional cardiology is possible when chest doses are well below regulatory limits. However, caution is required when extending its use to non-cardiac procedures, where procedure-specific exposure conditions may compromise the reliability of lens dose estimates.
- 4 April 2019
- Published by Springer Nature in La radiologia medica
- Vol. 124 (8) , 736-744
Protecting sensitive patient groups from imaging using ionizing radiation: effects during pregnancy, in fetal life and childhood
The frequency of imaging examinations requiring radiation exposure in children (especially CT) is rapidly increasing. This paper reviews the current evidence in radiation protection in pediatric imaging, focusing on the recent knowledge of the biological risk related to low doses exposure. Even if there are no strictly defined limits for patient radiation exposure, it is recommended to try to keep doses as low as reasonably achievable (the ALARA principle). To achieve ALARA, several techniques to reduce the radiation dose in radiation-sensitive patients groups are reviewed. The most recent recommendations that provide guidance regarding imaging of pregnant women are also summarized, and the risk depending on dose and phase of pregnancy is reported. Finally, the risk-benefit analysis of each examination, and careful communication of this risk to the patient, is emphasized.
- 4 April 2019
- Published by Springer Nature in La radiologia medica
- Vol. 124 (8) , 736-744
Protecting sensitive patient groups from imaging using ionizing radiation: effects during pregnancy, in fetal life and childhood
The frequency of imaging examinations requiring radiation exposure in children (especially CT) is rapidly increasing. This paper reviews the current evidence in radiation protection in pediatric imaging, focusing on the recent knowledge of the biological risk related to low doses exposure. Even if there are no strictly defined limits for patient radiation exposure, it is recommended to try to keep doses as low as reasonably achievable (the ALARA principle). To achieve ALARA, several techniques to reduce the radiation dose in radiation-sensitive patients groups are reviewed. The most recent recommendations that provide guidance regarding imaging of pregnant women are also summarized, and the risk depending on dose and phase of pregnancy is reported. Finally, the risk-benefit analysis of each examination, and careful communication of this risk to the patient, is emphasized.
- 3 May 2018
- Published by Springer Nature in La radiologia medica
- Vol. 123 (9) , 695-702
Is MRI imaging in pediatric age totally safe? A critical reprisal
Current radiological literature is strongly focussed on radiation imaging risks. Indeed, given there is a small but actual augment in cancer risk from exposure to ionizing radiation in children, it is important to understand what the risk of alternative techniques could be. We retrospectively review literature data concerning possible MR imaging risks, focussing on the biological effects of MR, sedation and gadolinium compound risks when dealing with infant patients. The main concerns can be summarized in: (1) Biological effects of non-ionizing electromagnetic fields (EMF) employed—whose mechanisms of interaction with human tissues are polarization, induced current, and thermal heating, respectively. (2) Risks associated with noises produced during MRI examinations. (3) Hazards from ferromagnetic external and/or implanted devices—whose risk of being unintentionally brought inside MR room is higher in children than in adults. (4) Risks associated with sedation or general anaesthesia, essential problem in performing MR in very young patients, due to the exam long-lasting. (5) Risks related to gadolinium-based contrast agents, especially considering the newly reported brain deposition.
- 3 May 2018
- Published by Springer Nature in La radiologia medica
- Vol. 123 (9) , 695-702
Is MRI imaging in pediatric age totally safe? A critical reprisal
Current radiological literature is strongly focussed on radiation imaging risks. Indeed, given there is a small but actual augment in cancer risk from exposure to ionizing radiation in children, it is important to understand what the risk of alternative techniques could be. We retrospectively review literature data concerning possible MR imaging risks, focussing on the biological effects of MR, sedation and gadolinium compound risks when dealing with infant patients. The main concerns can be summarized in: (1) Biological effects of non-ionizing electromagnetic fields (EMF) employed—whose mechanisms of interaction with human tissues are polarization, induced current, and thermal heating, respectively. (2) Risks associated with noises produced during MRI examinations. (3) Hazards from ferromagnetic external and/or implanted devices—whose risk of being unintentionally brought inside MR room is higher in children than in adults. (4) Risks associated with sedation or general anaesthesia, essential problem in performing MR in very young patients, due to the exam long-lasting. (5) Risks related to gadolinium-based contrast agents, especially considering the newly reported brain deposition.
- 13 February 2018
- Published by Springer Nature in Pediatric Radiology
- Vol. 48 (5) , 715-721
Quantification of scatter radiation from radiographic procedures in a neonatal intensive care unit
In a neonatal intensive care unit (NICU), preterm infants are often exposed to a large number of radiographic examinations, which could cause adjacent neonates, family caregivers and staff members to be exposed to a dose amount due to scatter radiation.
- 13 February 2018
- Published by Springer Nature in Pediatric Radiology
- Vol. 48 (5) , 715-721
Quantification of scatter radiation from radiographic procedures in a neonatal intensive care unit
In a neonatal intensive care unit (NICU), preterm infants are often exposed to a large number of radiographic examinations, which could cause adjacent neonates, family caregivers and staff members to be exposed to a dose amount due to scatter radiation.
- 1 August 2017
- Published by Elsevier in Physica Medica
- Vol. 40, 122-129
A novel method for CT dosimetry with a suspended phantom setup
- 1 August 2017
- Published by Elsevier in Physica Medica
- Vol. 40, 122-129
A novel method for CT dosimetry with a suspended phantom setup
- 27 July 2017
- Published by Springer Nature in International Urogynecology Journal
- Vol. 28 (11) , 1755-1756
Urethral prolapse in a paediatric patient with urogenital bleeding: diagnosis by imaging
- 27 July 2017
- Published by Springer Nature in International Urogynecology Journal
- Vol. 28 (11) , 1755-1756
Urethral prolapse in a paediatric patient with urogenital bleeding: diagnosis by imaging
- 16 March 2017
- Published by Springer Nature in Pediatric Radiology
- Vol. 47 (7) , 889-891
Sonographic probabilities of appendicitis in children.
- 16 March 2017
- Published by Springer Nature in Pediatric Radiology
- Vol. 47 (7) , 889-891
Sonographic probabilities of appendicitis in children.
- 25 November 2016
- Published by Springer Nature in La radiologia medica
- Vol. 122 (3) , 215-220
Radiation exposure in diagnostic imaging: wisdom and prudence, but still a lot to understand
Since 2000, a series of scientific articles on CT have been raising increasing concern about the risk of radiation induced cancer in children. The alarming conclusions of some of these articles had international echo through global media, provoking widespread public concern. Actually, many of these alarming scientific publications appeared to be flawed by poor study design, but their conclusions were not openly contradicted. In US and Europe pediatric radiologists had to face a huge challenge, which brought to the Image Gently campaign and the Eurosafe initiative with the aim to rebut misinformation and to support medical radiation protection. The Linear No Threshold model—which is the base of contemporary radioprotection—is increasingly questioned by new recent studies suggesting that low dose radiation would decrease cancer risk thanks to the enhancement of immune system response. Actually, pediatric radiologists have to cope with many important issues and contradictory messages. Good medical practice includes good communication about the benefits and risks of health procedures, thus the communication of radiation risk is a key component for radiologists. When considering benefits and risks, an important risk is too often ignored: the risk that skipping a diagnostic exam may cause a misdiagnosis, and therefore, a poor outcome. We should emphasize that a risk from a radiological investigation is very small, if a risk at all, and we are not sure that there is a risk at very low doses, like those doses in the majority of X-ray procedures including CT.
- 25 November 2016
- Published by Springer Nature in La radiologia medica
- Vol. 122 (3) , 215-220
Radiation exposure in diagnostic imaging: wisdom and prudence, but still a lot to understand
Since 2000, a series of scientific articles on CT have been raising increasing concern about the risk of radiation induced cancer in children. The alarming conclusions of some of these articles had international echo through global media, provoking widespread public concern. Actually, many of these alarming scientific publications appeared to be flawed by poor study design, but their conclusions were not openly contradicted. In US and Europe pediatric radiologists had to face a huge challenge, which brought to the Image Gently campaign and the Eurosafe initiative with the aim to rebut misinformation and to support medical radiation protection. The Linear No Threshold model—which is the base of contemporary radioprotection—is increasingly questioned by new recent studies suggesting that low dose radiation would decrease cancer risk thanks to the enhancement of immune system response. Actually, pediatric radiologists have to cope with many important issues and contradictory messages. Good medical practice includes good communication about the benefits and risks of health procedures, thus the communication of radiation risk is a key component for radiologists. When considering benefits and risks, an important risk is too often ignored: the risk that skipping a diagnostic exam may cause a misdiagnosis, and therefore, a poor outcome. We should emphasize that a risk from a radiological investigation is very small, if a risk at all, and we are not sure that there is a risk at very low doses, like those doses in the majority of X-ray procedures including CT.