Dilbag Singh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dilbag Singh has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Kishore Kumar Deepak
Centre for Biomedical Engineering, Indian Institute of Technology, New Delhi, Delhi, India
4 shared publications - Vinod Kumar
Senior Member, IEEE, Electrical Engineering Department, Indian Institute of Technology Roorkee, Roorkee - 247 667, INDIA
4 shared publications B. S. Saini
Instrumentation & Control Engineering Dept. and Electronics & Communication Engineering Dept., Dr. B. R. Ambedkar National Institute of Technology, Jalandhar - 144 011, Punjab INDIA
2 shared publications- Butta Singh
Guru Nanak Dev University Regional Campus
2 shared publications - H. K. Verma
Department of Electrical Engineering, Indian Institute of Technology Roorkee, Roorkee 247667 (INDIA)
2 shared publications - Sukhwinder Singh
University Institute of Engineering and Technology, Panjab University
2 shared publications
Latest Publications
- 22 December 2025
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 38 (1) , 2
Analyzing Gastrocnemius-Soleus Muscle Activity on Velcroid Sloping Surfaces during Different Tasks in Human Body
- 22 December 2025
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 38 (1) , 2
Analyzing Gastrocnemius-Soleus Muscle Activity on Velcroid Sloping Surfaces during Different Tasks in Human Body
- 16 April 2022
- Published by Springer Nature
- p. 107-116
Performance Analysis of Wavelet Filters for Heart Rate Variability Analysis
- 16 April 2022
- Published by Springer Nature
- p. 107-116
Performance Analysis of Wavelet Filters for Heart Rate Variability Analysis
- Open Access
- 21 October 2017
- Published by MDPI AG in Technologies
- Vol. 5 (4) , 68
Quantification of Feto-Maternal Heart Rate from Abdominal ECG Signal Using Empirical Mode Decomposition for Heart Rate Variability Analysis
In this paper, a robust method of feto-maternal heart rate extraction from the non-invasive composite abdominal Electrocardiogram (aECG) signal is presented. The proposed method is based on the Complete Ensemble Empirical Mode Decomposition with Adaptive Noise (CEEMDAN) method, in which a composite aECG signal is decomposed into its constituent frequency components called Intrinsic Mode Functions (IMFs) or simply “modes”, with better spectral separation. Decomposed IMFs are then selected manually according to probable maternal and fetal heart rate information and are processed further for quantification of maternal and fetal heart rate and variability analysis. The proposed method was applied to aECG recordings collected from three different sources: (i) the PhysioNet (adfecgdb) database; (ii) the PhysioNet (nifecgdb) database; and (iii) synthetic aECG signal generated from mathematical modeling in the LabVIEW software environment. An overall sensitivity of 98.83%, positive diagnostic value of 97.97%, accuracy of 96.93% and performance index of 96.75% were obtained in the case of Maternal Heart Rate (MHR) quantification, and an overall sensitivity of 98.13%, positive diagnostic value of 97.62%, accuracy of 95.91% and performance index of 95.69% were obtained in case of Fetal Heart Rate (FHR) quantification. The obtained results confirm that CEEMDAN is a very robust and accurate method for extraction of feto-maternal heart rate components from aECG signals. We also conclude that non-invasive aECG is an effective and reliable method for long-term FHR and MHR monitoring during pregnancy and labor. The requirement of manual intervention while selecting the probable maternal and fetal components from “n” number of decomposed modes limits the real-time application of the proposed methodology. This is due to the fact that the number of modes “n” produced by the CEEMDAN decomposition is unpredictable. However, the proposed methodology is well suited for applications where a small time-delay or offset in feto-maternal monitoring can be acceptable. In future, application-specific modification of the CEEMDAN algorithm can be implemented to eliminate manual intervention completely and will be suitable for long-term feto-maternal monitoring.
- 21 October 2017
- Published by MDPI AG in Technologies
- Vol. 5 (4) , 68
Open AccessQuantification of Feto-Maternal Heart Rate from Abdominal ECG Signal Using Empirical Mode Decomposition for Heart Rate Variability Analysis
In this paper, a robust method of feto-maternal heart rate extraction from the non-invasive composite abdominal Electrocardiogram (aECG) signal is presented. The proposed method is based on the Complete Ensemble Empirical Mode Decomposition with Adaptive Noise (CEEMDAN) method, in which a composite aECG signal is decomposed into its constituent frequency components called Intrinsic Mode Functions (IMFs) or simply “modes”, with better spectral separation. Decomposed IMFs are then selected manually according to probable maternal and fetal heart rate information and are processed further for quantification of maternal and fetal heart rate and variability analysis. The proposed method was applied to aECG recordings collected from three different sources: (i) the PhysioNet (adfecgdb) database; (ii) the PhysioNet (nifecgdb) database; and (iii) synthetic aECG signal generated from mathematical modeling in the LabVIEW software environment. An overall sensitivity of 98.83%, positive diagnostic value of 97.97%, accuracy of 96.93% and performance index of 96.75% were obtained in the case of Maternal Heart Rate (MHR) quantification, and an overall sensitivity of 98.13%, positive diagnostic value of 97.62%, accuracy of 95.91% and performance index of 95.69% were obtained in case of Fetal Heart Rate (FHR) quantification. The obtained results confirm that CEEMDAN is a very robust and accurate method for extraction of feto-maternal heart rate components from aECG signals. We also conclude that non-invasive aECG is an effective and reliable method for long-term FHR and MHR monitoring during pregnancy and labor. The requirement of manual intervention while selecting the probable maternal and fetal components from “n” number of decomposed modes limits the real-time application of the proposed methodology. This is due to the fact that the number of modes “n” produced by the CEEMDAN decomposition is unpredictable. However, the proposed methodology is well suited for applications where a small time-delay or offset in feto-maternal monitoring can be acceptable. In future, application-specific modification of the CEEMDAN algorithm can be implemented to eliminate manual intervention completely and will be suitable for long-term feto-maternal monitoring.
- Open Access
- 30 July 2017
- Published by Academy and Industry Research Collaboration Center (AIRCC) in International Journal of Instrumentation and Control Systems
- Vol. 7 (3) , 15-25
Real Time Data Acquisation of Solar Panel Using Arduino and Further Recording Voltage of the Solar Panel
- 30 July 2017
- Published by Academy and Industry Research Collaboration Center (AIRCC) in International Journal of Instrumentation and Control Systems
- Vol. 7 (3) , 15-25
Open AccessReal Time Data Acquisation of Solar Panel Using Arduino and Further Recording Voltage of the Solar Panel
- 1 July 2013
- Published by Elsevier in Journal of Electrocardiology
- Vol. 46 (4) , e21
Fractal dimension of electrocardiogram: distinguishing healthy and heart-failure patients
- 1 July 2013
- Published by Elsevier in Journal of Electrocardiology
- Vol. 46 (4) , e21
Fractal dimension of electrocardiogram: distinguishing healthy and heart-failure patients
- 1 May 2012
- Published by Taylor & Francis in International Journal of Systems Science
- Vol. 43 (5) , 884-893
Ectopic beats in approximate entropy and sample entropy-based HRV assessment
Approximate entropy (ApEn) and sample entropy (SampEn) are the promising techniques for extracting complex characteristics of cardiovascular variability. Ectopic beats, originating from other than the normal site, are the artefacts contributing a serious limitation to heart rate variability (HRV) analysis. The approaches like deletion and interpolation are currently in use to eliminate the bias produced by ectopic beats. In this study, normal R–R interval time series of 10 healthy and 10 acute myocardial infarction (AMI) patients were analysed by inserting artificial ectopic beats. Then the effects of ectopic beats editing by deletion, degree-zero and degree-one interpolation on ApEn and SampEn have been assessed. Ectopic beats addition (even 2%) led to reduced complexity, resulting in decreased ApEn and SampEn of both healthy and AMI patient data. This reduction has been found to be dependent on level of ectopic beats. Editing of ectopic beats by interpolation degree-one method is found to be superior to other methods.
- 1 May 2012
- Published by Taylor & Francis in International Journal of Systems Science
- Vol. 43 (5) , 884-893
Ectopic beats in approximate entropy and sample entropy-based HRV assessment
Approximate entropy (ApEn) and sample entropy (SampEn) are the promising techniques for extracting complex characteristics of cardiovascular variability. Ectopic beats, originating from other than the normal site, are the artefacts contributing a serious limitation to heart rate variability (HRV) analysis. The approaches like deletion and interpolation are currently in use to eliminate the bias produced by ectopic beats. In this study, normal R–R interval time series of 10 healthy and 10 acute myocardial infarction (AMI) patients were analysed by inserting artificial ectopic beats. Then the effects of ectopic beats editing by deletion, degree-zero and degree-one interpolation on ApEn and SampEn have been assessed. Ectopic beats addition (even 2%) led to reduced complexity, resulting in decreased ApEn and SampEn of both healthy and AMI patient data. This reduction has been found to be dependent on level of ectopic beats. Editing of ectopic beats by interpolation degree-one method is found to be superior to other methods.
- 19 January 2012
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 3 (2) , 211-216
Effect of Threshold Value r on Multiscale Entropy based Heart Rate Variability
- 19 January 2012
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 3 (2) , 211-216
Effect of Threshold Value r on Multiscale Entropy based Heart Rate Variability
- Open Access
- 1 January 2011
- Published by DAAAM International
- p. 0339-0340
Sensor Fusion Frame Work for Marble/Stone Processing Industry Using Low Cost Sensors
- 1 January 2011
- Published by DAAAM International
- p. 0339-0340
Open AccessSensor Fusion Frame Work for Marble/Stone Processing Industry Using Low Cost Sensors