Chang Ye Gue
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chang Ye Gue has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Kenichi Soga
Univ. of California, Berkeley
2 shared publications - Loizos Pelecanos
University of Bath, Bath, UK
2 shared publications M. M. Alhaddad
Univ. of Cambridge
2 shared publications- Mohammed Z. E. B. Elshafie
Univ. of Cambridge
2 shared publications - Nicholas De Battista
Research Associate, Centre for Smart Infrastructure and Construction, Dept. of Engineering, Univ. of Cambridge, Trumpington St., Cambridge CB2 1PZ, U.K.
2 shared publications R. J. Mair
Univ. of Cambridge
2 shared publications
Latest Publications
- 1 March 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Geotechnical and Geoenvironmental Engineering
- Vol. 144 (3)
Distributed Fiber Optic Sensing of Axially Loaded Bored Piles
Instrumented pile tests are vital to establish the performance of a pile and validate the assumptions made during initial design. Conventional instrumentation includes vibrating wire strain gauges and extensometers to measure the change in strain or displacements within a pile. Although these strain and displacement gauges are very accurate, they only provide strain/displacement readings at discrete locations at which they are installed. It is therefore common to interpolate between two consecutive points to obtain values corresponding to the data gaps between points; in practice, these discrete instrumented points could be tens of meters apart, at depths corresponding to different soil layers, and hence simple interpolation between the measurement points remains questionable. The Brillouin optical time-domain reflectometry fiber optic strain sensing system is able to provide distributed strain sensing along the entire length of the cable, enabling the full strain profile to be measured during a maintained pile load test. The strain data can also be integrated to obtain the displacement profile. This paper presents three case studies which investigate the performance of three concrete bored piles in London using both conventional vibrating wire strain gauges and distributed fiber optic strain sensing during maintained pile load tests, which enable comparisons made between the two instrumentation systems. In addition, finite-element analyses show that the ability to measure the full strain profiles for each pile is highly advantageous in understanding the performance of the pile and in detecting any abnormalities in the pile behavior.
- 1 March 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Geotechnical and Geoenvironmental Engineering
- Vol. 144 (3)
Distributed Fiber Optic Sensing of Axially Loaded Bored Piles
Instrumented pile tests are vital to establish the performance of a pile and validate the assumptions made during initial design. Conventional instrumentation includes vibrating wire strain gauges and extensometers to measure the change in strain or displacements within a pile. Although these strain and displacement gauges are very accurate, they only provide strain/displacement readings at discrete locations at which they are installed. It is therefore common to interpolate between two consecutive points to obtain values corresponding to the data gaps between points; in practice, these discrete instrumented points could be tens of meters apart, at depths corresponding to different soil layers, and hence simple interpolation between the measurement points remains questionable. The Brillouin optical time-domain reflectometry fiber optic strain sensing system is able to provide distributed strain sensing along the entire length of the cable, enabling the full strain profile to be measured during a maintained pile load test. The strain data can also be integrated to obtain the displacement profile. This paper presents three case studies which investigate the performance of three concrete bored piles in London using both conventional vibrating wire strain gauges and distributed fiber optic strain sensing during maintained pile load tests, which enable comparisons made between the two instrumentation systems. In addition, finite-element analyses show that the ability to measure the full strain profiles for each pile is highly advantageous in understanding the performance of the pile and in detecting any abnormalities in the pile behavior.
- 1 January 2018
- Published by Elsevier
List of Contributors
- 30 March 2017
- Published by American Society of Civil Engineers (ASCE)
- p. 525-535
Monitoring the Behaviour of an Existing Royal Mail Tunnel: London Underground Bond Street Station Upgrade Works
The response of existing tunnels to adjacent new tunnelling works is an area of special interest to both civil engineering designers and tunnelling engineers as well as asset owners. Field monitoring is critical as it provides vital data about the response of the existing tunnels that informs future design improvements. This paper focuses on the response of the existing, near century-old Royal Mail Tunnel in the vicinity of bond street London underground station in London, U.K. Cambridge’s ‘Centre for Smart Infrastructure and Construction’ (CSIC) deployed various state-of-the-art instrumentation systems to investigate the behaviour of the existing Royal Mail Tunnel during the construction of a new passenger tunnel as part of London underground bond street upgrade scheme. The instrumentation includes distributed fibre optic strain sensing (DFOS), photogrammetry and strain gauge instrumented tunnel bolts. The monitoring systems combined were able to provide a very good insight into the existing Royal Mail Tunnel behaviour, as the construction of the new tunnel beneath was undertaken.
- 30 March 2017
- Published by American Society of Civil Engineers (ASCE)
- p. 525-535
Monitoring the Behaviour of an Existing Royal Mail Tunnel: London Underground Bond Street Station Upgrade Works
The response of existing tunnels to adjacent new tunnelling works is an area of special interest to both civil engineering designers and tunnelling engineers as well as asset owners. Field monitoring is critical as it provides vital data about the response of the existing tunnels that informs future design improvements. This paper focuses on the response of the existing, near century-old Royal Mail Tunnel in the vicinity of bond street London underground station in London, U.K. Cambridge’s ‘Centre for Smart Infrastructure and Construction’ (CSIC) deployed various state-of-the-art instrumentation systems to investigate the behaviour of the existing Royal Mail Tunnel during the construction of a new passenger tunnel as part of London underground bond street upgrade scheme. The instrumentation includes distributed fibre optic strain sensing (DFOS), photogrammetry and strain gauge instrumented tunnel bolts. The monitoring systems combined were able to provide a very good insight into the existing Royal Mail Tunnel behaviour, as the construction of the new tunnel beneath was undertaken.
- Open Access
- 29 March 2015
- Published by Springer Nature in Journal of Civil Structural Health Monitoring
- Vol. 5 (5) , 573-586
The monitoring of an existing cast iron tunnel with distributed fibre optic sensing (DFOS)
- 29 March 2015
- Published by Springer Nature in Journal of Civil Structural Health Monitoring
- Vol. 5 (5) , 573-586
Open AccessThe monitoring of an existing cast iron tunnel with distributed fibre optic sensing (DFOS)