CGChang Ye Gue

Chang Ye Gue

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chang Ye Gue has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Distributed Fiber Optic Sensing of Axially Loaded Bored Piles

    by Loizos Pelecanos, Kenichi Soga, Mohammed Z. E. B. Elshafie, Nicholas de Battista, Cedric Kechavarzi, Chang Ye Gue, Yue Ouyang, Hyung-Joon Seo

    Instrumented pile tests are vital to establish the performance of a pile and validate the assumptions made during initial design. Conventional instrumentation includes vibrating wire strain gauges and extensometers to measure the change in strain or displacements within a pile. Although these strain and displacement gauges are very accurate, they only provide strain/displacement readings at discrete locations at which they are installed. It is therefore common to interpolate between two consecutive points to obtain values corresponding to the data gaps between points; in practice, these discrete instrumented points could be tens of meters apart, at depths corresponding to different soil layers, and hence simple interpolation between the measurement points remains questionable. The Brillouin optical time-domain reflectometry fiber optic strain sensing system is able to provide distributed strain sensing along the entire length of the cable, enabling the full strain profile to be measured during a maintained pile load test. The strain data can also be integrated to obtain the displacement profile. This paper presents three case studies which investigate the performance of three concrete bored piles in London using both conventional vibrating wire strain gauges and distributed fiber optic strain sensing during maintained pile load tests, which enable comparisons made between the two instrumentation systems. In addition, finite-element analyses show that the ability to measure the full strain profiles for each pile is highly advantageous in understanding the performance of the pile and in detecting any abnormalities in the pile behavior.


  • List of Contributors

    by Traian E. Abrudan, Aaron Bradshaw, Erika Bustos, Liang Cheng, Nicholas De Battista, Vanessa Di Murro, Mohammed Elshafie, J.A. Garcia, Russell A. Green, C.Y. Gue, et al.

  • Monitoring the Behaviour of an Existing Royal Mail Tunnel: London Underground Bond Street Station Upgrade Works

    by C. Y. Gue, M. J. Wilcock, M. M. Alhaddad, M. Z. E. B. Elshafie, K. Soga, R. J. Mair

    The response of existing tunnels to adjacent new tunnelling works is an area of special interest to both civil engineering designers and tunnelling engineers as well as asset owners. Field monitoring is critical as it provides vital data about the response of the existing tunnels that informs future design improvements. This paper focuses on the response of the existing, near century-old Royal Mail Tunnel in the vicinity of bond street London underground station in London, U.K. Cambridge’s ‘Centre for Smart Infrastructure and Construction’ (CSIC) deployed various state-of-the-art instrumentation systems to investigate the behaviour of the existing Royal Mail Tunnel during the construction of a new passenger tunnel as part of London underground bond street upgrade scheme. The instrumentation includes distributed fibre optic strain sensing (DFOS), photogrammetry and strain gauge instrumented tunnel bolts. The monitoring systems combined were able to provide a very good insight into the existing Royal Mail Tunnel behaviour, as the construction of the new tunnel beneath was undertaken.


  • Open Access

    The monitoring of an existing cast iron tunnel with distributed fibre optic sensing (DFOS)

    by C. Y. Gue, M. Wilcock, M. M. Alhaddad, M. Z. E. B. Elshafie, K. Soga, R. J. Mair