Quan Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Quan Tang has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Cong Guo
Experimental Physics Division, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
8 shared publications J. C. Liu
5 shared publicationsY. P. Zhang
5 shared publicationsC. G. Yang
4 shared publicationsC. Li
School of Nuclear Science and Technology University of South China 421001 Hengyang China
4 shared publicationsChanggen Yang
Experimental Physics Division, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
4 shared publications
Latest Publications
- 6 May 2025
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 236 (7) , 1-12
Efficient Removal of Iodide from Medical Wastewater by D201 Resin
- 6 May 2025
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 236 (7) , 1-12
Efficient Removal of Iodide from Medical Wastewater by D201 Resin
- 30 July 2024
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 333 (11) , 5741-5746
A new method for the measurement of the activity of high-concentration 226Ra in solution based on 222Rn production rate
- 30 July 2024
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 333 (11) , 5741-5746
A new method for the measurement of the activity of high-concentration 226Ra in solution based on 222Rn production rate
- Open Access
Development of low-radon ultra-pure water for the Jiangmen Underground Neutrino Observatory
The Jiangmen Underground Neutrino Observatory(JUNO) is a state-of-the-art liquid scintillator-based neutrino physics experiment under construction in South China. To reduce the background from external radioactivities, a water Cherenkov detector composed of 35~kton ultra-pure water and 2,400 20-inch photomultiplier tubes is developed. Even after specialized treatment, ultra-pure water still contains trace levels of radioactive elements that can contribute to the detector background. Among which $^{222}$Rn is particularly significant. To address this, an online radon removal system based on the JUNO prototype has been developed. By integrating micro-bubble generators to enhance degasser's radon removal efficiency, the radon concentration in water can be reduced to 1~mBq/m$^{3}$ level, meeting the stringent requirements of JUNO. Additionally, a highly sensitive online radon concentration measurement system capable of detecting concentrations $\sim$1~mBq/m$^3$ has been developed to monitor the radon concentration in water. In this paper, the details regarding both systems will be presented.Open AccessDevelopment of low-radon ultra-pure water for the Jiangmen Underground Neutrino Observatory
The Jiangmen Underground Neutrino Observatory(JUNO) is a state-of-the-art liquid scintillator-based neutrino physics experiment under construction in South China. To reduce the background from external radioactivities, a water Cherenkov detector composed of 35~kton ultra-pure water and 2,400 20-inch photomultiplier tubes is developed. Even after specialized treatment, ultra-pure water still contains trace levels of radioactive elements that can contribute to the detector background. Among which $^{222}$Rn is particularly significant. To address this, an online radon removal system based on the JUNO prototype has been developed. By integrating micro-bubble generators to enhance degasser's radon removal efficiency, the radon concentration in water can be reduced to 1~mBq/m$^{3}$ level, meeting the stringent requirements of JUNO. Additionally, a highly sensitive online radon concentration measurement system capable of detecting concentrations $\sim$1~mBq/m$^3$ has been developed to monitor the radon concentration in water. In this paper, the details regarding both systems will be presented. - Open AccessDeveloping a $μ$Bq/m$^{3}$ level $^{226}$Ra concentration in water measurement system for the Jiangmen Underground Neutrino ObservatoryThe Jiangmen Underground Neutrino Observatory (JUNO), a 20~kton multi-purpose low background Liquid Scintillator (LS) detector, was proposed primarily to determine the neutrino mass ordering. To suppress the radioactivity from the surrounding rocks and tag cosmic muons, the JUNO central detector is submerged in a Water Cherenkov Detector (WCD). In addition to being used in the WCD, ultrapure water is used in LS filling, for which the $^{226}$Ra concentration in water needs to be less than 50~$μ$Bq/m$^3$. To precisely measure the $^{226}$Ra concentration in water, a 6.0~$μ$Bq/m$^3$ $^{226}$Ra concentration in water measurement system has been developed. In this paper, the detail of the measurement system as well as the $^{226}$Ra concentration measurement result in regular EWII ultrapure water will be presented.Open AccessDeveloping a $μ$Bq/m$^{3}$ level $^{226}$Ra concentration in water measurement system for the Jiangmen Underground Neutrino ObservatoryThe Jiangmen Underground Neutrino Observatory (JUNO), a 20~kton multi-purpose low background Liquid Scintillator (LS) detector, was proposed primarily to determine the neutrino mass ordering. To suppress the radioactivity from the surrounding rocks and tag cosmic muons, the JUNO central detector is submerged in a Water Cherenkov Detector (WCD). In addition to being used in the WCD, ultrapure water is used in LS filling, for which the $^{226}$Ra concentration in water needs to be less than 50~$μ$Bq/m$^3$. To precisely measure the $^{226}$Ra concentration in water, a 6.0~$μ$Bq/m$^3$ $^{226}$Ra concentration in water measurement system has been developed. In this paper, the detail of the measurement system as well as the $^{226}$Ra concentration measurement result in regular EWII ultrapure water will be presented.
- 1 November 2023
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 333 (1) , 337-346
Study on the radon adsorption capability of low-background activated carbon
- 1 November 2023
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 333 (1) , 337-346
Study on the radon adsorption capability of low-background activated carbon
- Open Access
Study on the radon adsorption capability of low-background activated carbon
Radon is a significant background source in rare event detection experiments. Activated Carbon (AC) adsorption is widely used for effective radon removal. The selection of AC considers its adsorption capacity and radioactive background. In this study, using self-developed devices, we screened and identified a new kind of low-background AC from Qingdao Inaf Technology Company that has very high Radon adsorption capacity. By adjusting the average pore size to 2.3 nm, this AC demonstrates a radon adsorption capacity of 2.6 or 4.7 times higher than Saratech or Carboact activated carbon under the same conditions.
Open AccessStudy on the radon adsorption capability of low-background activated carbon
Radon is a significant background source in rare event detection experiments. Activated Carbon (AC) adsorption is widely used for effective radon removal. The selection of AC considers its adsorption capacity and radioactive background. In this study, using self-developed devices, we screened and identified a new kind of low-background AC from Qingdao Inaf Technology Company that has very high Radon adsorption capacity. By adjusting the average pore size to 2.3 nm, this AC demonstrates a radon adsorption capacity of 2.6 or 4.7 times higher than Saratech or Carboact activated carbon under the same conditions.
- Open AccessSystem upgrade for $μ$Bq/m$^3$ level $^{222}$Rn concentration measurementThe Jiangmen Underground Neutrino Observatory (JUNO), a 20 kton multipurpose underground liquid scintillator detector, was proposed for the determination of the neutrino mass hierarchy as primary physics goal. The central detector will be submerged in a water Cherenkov detector to lower the background from the environment and cosmic muons. Radon is one of the primary background sources. Nitrogen will be used in several sub-systems, and a highly sensitive radon detector has to be developed to measure its radon concentration. A system has been developed based on $^{222}$Rn enrichment of activated carbon and $^{222}$Rn detection based on the electrostatic collection. This paper presents the detail of a $μ$Bq/m$^3$ level $^{222}$Rn concentration measurement system and gives detailed information about how the adsorption coefficient was measured and how the temperature, flow rate, and $^{222}$Rn concentration affect the adsorption coefficient.Open AccessSystem upgrade for $μ$Bq/m$^3$ level $^{222}$Rn concentration measurementThe Jiangmen Underground Neutrino Observatory (JUNO), a 20 kton multipurpose underground liquid scintillator detector, was proposed for the determination of the neutrino mass hierarchy as primary physics goal. The central detector will be submerged in a water Cherenkov detector to lower the background from the environment and cosmic muons. Radon is one of the primary background sources. Nitrogen will be used in several sub-systems, and a highly sensitive radon detector has to be developed to measure its radon concentration. A system has been developed based on $^{222}$Rn enrichment of activated carbon and $^{222}$Rn detection based on the electrostatic collection. This paper presents the detail of a $μ$Bq/m$^3$ level $^{222}$Rn concentration measurement system and gives detailed information about how the adsorption coefficient was measured and how the temperature, flow rate, and $^{222}$Rn concentration affect the adsorption coefficient.
- 26 April 2023
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 332 (6) , 1841-1845
Optimisation of uranium–radium co-leaching from uranium ore
- 26 April 2023
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 332 (6) , 1841-1845
Optimisation of uranium–radium co-leaching from uranium ore
- Open Access
Research of radon diffusion behavior in liquid scintillator
The background caused by radon and its daughters is an important background in the low background liquid scintillator (LS) detectors. The study of the diffusion behaviour of radon in the LS contributes to the analysis of the related background caused by radon. Methodologies and devices for measuring the diffusion coefficient and solubility of radon in materials are developed and described. The radon diffusion coefficient of the LS was measured for the first time and in addition the solubility coefficient was also obtained. In addition, the radon diffusion coefficient of the polyolefine film which is consistent with data in the literature was measured to verify the reliability of the diffusion device.
Open AccessResearch of radon diffusion behavior in liquid scintillator
The background caused by radon and its daughters is an important background in the low background liquid scintillator (LS) detectors. The study of the diffusion behaviour of radon in the LS contributes to the analysis of the related background caused by radon. Methodologies and devices for measuring the diffusion coefficient and solubility of radon in materials are developed and described. The radon diffusion coefficient of the LS was measured for the first time and in addition the solubility coefficient was also obtained. In addition, the radon diffusion coefficient of the polyolefine film which is consistent with data in the literature was measured to verify the reliability of the diffusion device.
- 23 March 2022
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 331 (4) , 1839-1845
Construction of a low-temperature activated carbon radon adsorption system using air cooler
- 23 March 2022
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 331 (4) , 1839-1845
Construction of a low-temperature activated carbon radon adsorption system using air cooler