Vladimir Yuhimenko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Vladimir Yuhimenko has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Alon Kuperman
Applied Energy Laboratory Ben‐Gurion University of the Negev Beer‐Sheva Israel
3 shared publications - Dmitry Baimel
Department of Electrical and Electronics Engineering, Sami Shamoon College of Engineering, Beer Sheva 8410802, Israel
2 shared publications - Alexei Mutovkin
Ariel University, Ariel, Israel
1 shared publication - Martin Mellincovsky
Ariel University, Israel
1 shared publication - Moshe Averbukh
Department of Electrical/Electronic Engineering, Ariel University, Ariel 40700, Israel
1 shared publication - Moshe Sitbon
Department of Electrical and Electronics Engineering, Ariel University, Ariel 40700, Israel
1 shared publication
Latest Publications
- Open Access
Baseline for Split DC Link Design in Three-Phase Three-Level Converters Operating with Unity Power Factor Based on Low-Frequency Partial Voltage Oscillations
The study sets a baseline for split DC link capacitance values and voltage set points in three-phase three-level AC/DC (or DC/AC) converters operating with unity power factor. In order to equalize the average values of partial DC link voltages, the controller generates a zero-sequence containing DC components only while employing neither dedicated DC link capacitance balancing hardware nor high-order zero-sequence component injection. Such a baseline is required in order to evaluate the effectiveness of different DC link capacitance reduction methods proposed in the literature. Unlike most previous works, utilizing neutral point current based on cumbersome analytical expressions to determine neutral point potential oscillations, the instantaneous power balance-based approach is employed in this paper, resulting in greatly simplified and more intuitive expressions. It is demonstrated that while the total DC link voltage is low-frequency ripple-free under unity power factor balanced AC-side operation, split DC link capacitors absorb triple-fundamental frequency power components with one-sixth load power magnitude. This yields significant opposite phase partial voltage ripples. In such a case, selection of DC link capacitances and voltage set points must take into account the expected values of AC-side phase voltage magnitude and split DC link capacitor voltage and current ratings. Simulation and experimental results validate the proposed methodology by application to a 10 kVA T-type converter prototype.
Open AccessBaseline for Split DC Link Design in Three-Phase Three-Level Converters Operating with Unity Power Factor Based on Low-Frequency Partial Voltage Oscillations
The study sets a baseline for split DC link capacitance values and voltage set points in three-phase three-level AC/DC (or DC/AC) converters operating with unity power factor. In order to equalize the average values of partial DC link voltages, the controller generates a zero-sequence containing DC components only while employing neither dedicated DC link capacitance balancing hardware nor high-order zero-sequence component injection. Such a baseline is required in order to evaluate the effectiveness of different DC link capacitance reduction methods proposed in the literature. Unlike most previous works, utilizing neutral point current based on cumbersome analytical expressions to determine neutral point potential oscillations, the instantaneous power balance-based approach is employed in this paper, resulting in greatly simplified and more intuitive expressions. It is demonstrated that while the total DC link voltage is low-frequency ripple-free under unity power factor balanced AC-side operation, split DC link capacitors absorb triple-fundamental frequency power components with one-sixth load power magnitude. This yields significant opposite phase partial voltage ripples. In such a case, selection of DC link capacitances and voltage set points must take into account the expected values of AC-side phase voltage magnitude and split DC link capacitor voltage and current ratings. Simulation and experimental results validate the proposed methodology by application to a 10 kVA T-type converter prototype.
- Open Access
- 21 April 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (4) , 438
Hybrid Internal Combustion Engine Based Auxiliary Power Unit
The brief presents some principles of the ON/OFF operational strategy applied to energy management of a hybrid internal combustion engine (ICE) based auxiliary power unit (APU). It is shown that significant reduction of fuel consumption (78% for the example system presented) and maintenance expenses (80% operation time decrease was attained by the system) may be achieved by such a strategy, shifting the system operation point towards corresponding optimal region. The side effect of aggravated amount of starting events is cured by employing an actively balanced supercapacitor (SC)-based emergency starter (SCS). The SCS operates as short-time energy storage device, charging from the battery at a low rate and then providing a current burst required for proper internal combustion engine starting. Current sensorless method of automatic connection (based on bus voltage sensing) and disconnection (based on sensing the voltage across bidirectional MOSFET-based switch) of the SCS is also proposed. The proposed circuitry, successfully validated by experiments, may be arbitrarily scaled up or down according to application rating.
- 21 April 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (4) , 438
Open AccessHybrid Internal Combustion Engine Based Auxiliary Power Unit
The brief presents some principles of the ON/OFF operational strategy applied to energy management of a hybrid internal combustion engine (ICE) based auxiliary power unit (APU). It is shown that significant reduction of fuel consumption (78% for the example system presented) and maintenance expenses (80% operation time decrease was attained by the system) may be achieved by such a strategy, shifting the system operation point towards corresponding optimal region. The side effect of aggravated amount of starting events is cured by employing an actively balanced supercapacitor (SC)-based emergency starter (SCS). The SCS operates as short-time energy storage device, charging from the battery at a low rate and then providing a current burst required for proper internal combustion engine starting. Current sensorless method of automatic connection (based on bus voltage sensing) and disconnection (based on sensing the voltage across bidirectional MOSFET-based switch) of the SCS is also proposed. The proposed circuitry, successfully validated by experiments, may be arbitrarily scaled up or down according to application rating.
- 20 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (8) , 6527-6537
Control of Direct Voltage Regulated Active DC-Link Capacitance Reduction Circuits to Allow Plug-and-Play Operation
Novel method for controlling direct voltage regulated active DC link capacitance reduction circuits (ACRC) is proposed in the paper. Instead of forcing the DC link voltage of the power conversion system to follow a constant reference, the ACRC imposes DC bus voltage in proportion to the integral of its input current. Consequently, it resembles an adjustable value capacitor from the DC link side. Therefore, as opposed to existing control strategies, the proposed method simultaneously allows the DC link voltage to reflect the power balance of the system and the pulsating power component to be diverted into significantly reduced auxiliary capacitance via a bidirectional DC-DC converter. As a result, replacing bulk DC link capacitance by the proposed circuitry does not require any modification of existing grid-connected power conversion system controllers, thus allowing plug-and-play operation. The proposed approach is validated by application to a commercial PFC front end by both simulations and experiments.
- 20 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (8) , 6527-6537
Control of Direct Voltage Regulated Active DC-Link Capacitance Reduction Circuits to Allow Plug-and-Play Operation
Novel method for controlling direct voltage regulated active DC link capacitance reduction circuits (ACRC) is proposed in the paper. Instead of forcing the DC link voltage of the power conversion system to follow a constant reference, the ACRC imposes DC bus voltage in proportion to the integral of its input current. Consequently, it resembles an adjustable value capacitor from the DC link side. Therefore, as opposed to existing control strategies, the proposed method simultaneously allows the DC link voltage to reflect the power balance of the system and the pulsating power component to be diverted into significantly reduced auxiliary capacitance via a bidirectional DC-DC converter. As a result, replacing bulk DC link capacitance by the proposed circuitry does not require any modification of existing grid-connected power conversion system controllers, thus allowing plug-and-play operation. The proposed approach is validated by application to a commercial PFC front end by both simulations and experiments.