Sahana Pentyala
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sahana Pentyala has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Srinivas Pentyala
Department of Anesthesiology, Stony Brook University, Stony Brook, NY 11794, USA
3 shared publications - Thomas Tumillo
Department of Anesthesiology, Stony Brook Medical Center, Stony Brook, New York, NY 11794-8480, USA
2 shared publications - Vamiq M. Mustahsan
Department of Mechanical Engineering, Stony Brook University, Stony Brook, NY, USA
2 shared publications Aleef Rahman
1 shared publication- Amith Anugu
Department of Anesthesiology, Stony Brook University, Stony Brook, NY 11794, USA
1 shared publication - Avijit Roy
Department of Anesthesiology, Stony Brook Medical Center, Stony Brook, New York, NY 11794-8480, USA
1 shared publication
Latest Publications
- Open Access
- 22 October 2019
- Published by MDPI AG in Diagnostics
- Vol. 9 (4) , 157
Rapid Gout Detection Method and Kit
Gout is a form of arthritis characterized by buildup of uric acid in synovial fluid, which causes severe swelling and can harm joints, tendons, and other tissues. It affects approximately 4% of the United States population, or approximately 8.3 million people nationwide and is therefore a topic of epidemiologic consideration due to its prevalence. Gout is typically diagnosed via polarized microscopy of arthroscopically-aspirated synovial fluid, which is a costly, time-consuming, labor-intensive, and technically complex procedure, warranting a simpler and less complex method for diagnosis. Here, we propose and validate a colorimetric method which is based on the ability of uric acid to reduce silver nitrate. We also assessed how the colorimetric change can be accelerated by changing the concentration of silver nitrate or adding different silver catalysts, as well as develop a matrix bed for improved handling and ease of use. When translated to the clinic, this diagnostic method for gout will have the potential to increase diagnostic efficiency and accelerate patient care at the bedside.
- 22 October 2019
- Published by MDPI AG in Diagnostics
- Vol. 9 (4) , 157
Open AccessRapid Gout Detection Method and Kit
Gout is a form of arthritis characterized by buildup of uric acid in synovial fluid, which causes severe swelling and can harm joints, tendons, and other tissues. It affects approximately 4% of the United States population, or approximately 8.3 million people nationwide and is therefore a topic of epidemiologic consideration due to its prevalence. Gout is typically diagnosed via polarized microscopy of arthroscopically-aspirated synovial fluid, which is a costly, time-consuming, labor-intensive, and technically complex procedure, warranting a simpler and less complex method for diagnosis. Here, we propose and validate a colorimetric method which is based on the ability of uric acid to reduce silver nitrate. We also assessed how the colorimetric change can be accelerated by changing the concentration of silver nitrate or adding different silver catalysts, as well as develop a matrix bed for improved handling and ease of use. When translated to the clinic, this diagnostic method for gout will have the potential to increase diagnostic efficiency and accelerate patient care at the bedside.
- Open Access
- 22 December 2017
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 12 (1) , 1-9
Biomechanical properties of 3D-printed bone scaffolds are improved by treatment with CRFP
One of the major challenges in orthopedics is to develop implants that overcome current postoperative problems such as osteointegration, proper load bearing, and stress shielding. Current implant techniques such as allografts or endoprostheses never reach full bone integration, and the risk of fracture due to stress shielding is a major concern. To overcome this, a novel technique of reverse engineering to create artificial scaffolds was designed and tested. The purpose of the study is to create a new generation of implants that are both biocompatible and biomimetic. 3D-printed scaffolds based on physiological trabecular bone patterning were printed. MC3T3 cells were cultured on these scaffolds in osteogenic media, with and without the addition of Calcitonin Receptor Fragment Peptide (CRFP) in order to assess bone formation on the surfaces of the scaffolds. Integrity of these cell-seeded bone-coated scaffolds was tested for their mechanical strength. The results show that cellular proliferation and bone matrix formation are both supported by our 3D-printed scaffolds. The mechanical strength of the scaffolds was enhanced by trabecular patterning in the order of 20% for compression strength and 60% for compressive modulus. Furthermore, cell-seeded trabecular scaffolds modulus increased fourfold when treated with CRFP. Upon mineralization, the cell-seeded trabecular implants treated with osteo-inductive agents and pretreated with CRFP showed a significant increase in the compressive modulus. This work will lead to creating 3D structures that can be used in the replacement of not only bone segments, but entire bones.
- 22 December 2017
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 12 (1) , 1-9
Open AccessBiomechanical properties of 3D-printed bone scaffolds are improved by treatment with CRFP
One of the major challenges in orthopedics is to develop implants that overcome current postoperative problems such as osteointegration, proper load bearing, and stress shielding. Current implant techniques such as allografts or endoprostheses never reach full bone integration, and the risk of fracture due to stress shielding is a major concern. To overcome this, a novel technique of reverse engineering to create artificial scaffolds was designed and tested. The purpose of the study is to create a new generation of implants that are both biocompatible and biomimetic. 3D-printed scaffolds based on physiological trabecular bone patterning were printed. MC3T3 cells were cultured on these scaffolds in osteogenic media, with and without the addition of Calcitonin Receptor Fragment Peptide (CRFP) in order to assess bone formation on the surfaces of the scaffolds. Integrity of these cell-seeded bone-coated scaffolds was tested for their mechanical strength. The results show that cellular proliferation and bone matrix formation are both supported by our 3D-printed scaffolds. The mechanical strength of the scaffolds was enhanced by trabecular patterning in the order of 20% for compression strength and 60% for compressive modulus. Furthermore, cell-seeded trabecular scaffolds modulus increased fourfold when treated with CRFP. Upon mineralization, the cell-seeded trabecular implants treated with osteo-inductive agents and pretreated with CRFP showed a significant increase in the compressive modulus. This work will lead to creating 3D structures that can be used in the replacement of not only bone segments, but entire bones.
- Open Access
- 23 April 2015
- Published by MDPI AG in Diagnostics
- Vol. 5 (2) , 177-188
A Novel Point-of-Care Biomarker Recognition Method: Validation by Detecting Marker for Diabetic Nephropathy
Biological fluid collection to identify and analyze different disease markers is a routine and normal procedure in health care settings. Body fluids are as varied as urine, blood, mucus, cerebrospinal fluid (CSF), tears, semen, etc. The volumes of the collected fluids range from micro liters (e.g., tears, CSF) to tens and hundreds of milliliters (blood, urine, etc.). In some manifestations, a disease marker (particularly protein markers) can occur in trace amounts, yet the fluids collected are in large volumes. To identify these trace markers, cumbersome methods, expensive instruments, and trained personnel are required. We developed an easy method to rapidly capture, concentrate, and identify protein markers in large volumes of test fluids. This method involves the utilization of two antibodies recognizing two different epitopes of the protein biomarker. Antibody-1 helps to capture and concentrate the biomarker and Antibody-2 adsorbed or conjugated to nanogold beads will detect the biomarker. This method was validated in capturing and detecting lipocalin type prostaglandin-D2 synthase, a marker in urine that implicates diabetic nephropathy. A one-step collection, concentration, and detection device was designed based on this method. This device can replace many of the normal body fluid collection devices such as tubes and containers. A one-step fluid collection and biomarker capture and concentration device for rapid diagnosis of diseases has tremendous advantage in terms of cost and providing timely results.
- 23 April 2015
- Published by MDPI AG in Diagnostics
- Vol. 5 (2) , 177-188
Open AccessA Novel Point-of-Care Biomarker Recognition Method: Validation by Detecting Marker for Diabetic Nephropathy
Biological fluid collection to identify and analyze different disease markers is a routine and normal procedure in health care settings. Body fluids are as varied as urine, blood, mucus, cerebrospinal fluid (CSF), tears, semen, etc. The volumes of the collected fluids range from micro liters (e.g., tears, CSF) to tens and hundreds of milliliters (blood, urine, etc.). In some manifestations, a disease marker (particularly protein markers) can occur in trace amounts, yet the fluids collected are in large volumes. To identify these trace markers, cumbersome methods, expensive instruments, and trained personnel are required. We developed an easy method to rapidly capture, concentrate, and identify protein markers in large volumes of test fluids. This method involves the utilization of two antibodies recognizing two different epitopes of the protein biomarker. Antibody-1 helps to capture and concentrate the biomarker and Antibody-2 adsorbed or conjugated to nanogold beads will detect the biomarker. This method was validated in capturing and detecting lipocalin type prostaglandin-D2 synthase, a marker in urine that implicates diabetic nephropathy. A one-step collection, concentration, and detection device was designed based on this method. This device can replace many of the normal body fluid collection devices such as tubes and containers. A one-step fluid collection and biomarker capture and concentration device for rapid diagnosis of diseases has tremendous advantage in terms of cost and providing timely results.
- 29 June 2013
- Published by SciDoc Publishers LLC in International Journal of Clinical Therapeutics and Diagnosis
- p. 5-11
Osteoporosis in Female Athletes
- 29 June 2013
- Published by SciDoc Publishers LLC in International Journal of Clinical Therapeutics and Diagnosis
- p. 5-11
Osteoporosis in Female Athletes