Hideyuki Hirata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hideyuki Hirata has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Shuxiang Guo
Department of Electronic and Electrical Engineering, Southern University of Science and Technology, Shenzhen, China
5 shared publications - Hidenori Ishihara
Kagawa Univ
4 shared publications - Baofeng Gao
Beijing Institute of Technology, Beijing, China
2 shared publications - Songyuan Zhang
Harbin Institute of Technology
2 shared publications - Muye Pang
Faculty of Engineering, Kagawa University, Hayashi-cho, Takamatsu 761-0369, Japan
1 shared publication - Qiang Fu
Graduate School of Engineering, Kagawa University, 2217-20, Hayashi-cho, Takamatsu 761-0396, Japan
1 shared publication
Latest Publications
- 29 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (5) , 1529-1541
A Home-Based Bilateral Rehabilitation System With sEMG-based Real-Time Variable Stiffness
Bilateral rehabilitation allows patients with hemiparesis to exploit the cooperative capabilities of both arms to promote the recovery process. Although various approaches have been proposed to facilitate synchronized robot-assisted bilateral movements, few studies have focused on addressing the varying joint stiffness resulting from dynamic motions. This paper presents a novel bilateral rehabilitation system that implements a surface electromyography (sEMG)-based stiffness control to achieve real-time stiffness adjustment based on the user's dynamic motion. An sEMG-driven musculoskeletal model that incorporates muscle activation and muscular contraction dynamics is developed to provide reference signals for the robot's real-time stiffness control. Preliminary experiments were conducted to evaluate the system performance in tracking accuracy and comfortability, which showed the proposed rehabilitation system with sEMG-based real-time stiffness variation achieved fast adaption to the patient's dynamic movement as well as improving the comfort in robot-assisted bilateral training.
- 29 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (5) , 1529-1541
A Home-Based Bilateral Rehabilitation System With sEMG-based Real-Time Variable Stiffness
Bilateral rehabilitation allows patients with hemiparesis to exploit the cooperative capabilities of both arms to promote the recovery process. Although various approaches have been proposed to facilitate synchronized robot-assisted bilateral movements, few studies have focused on addressing the varying joint stiffness resulting from dynamic motions. This paper presents a novel bilateral rehabilitation system that implements a surface electromyography (sEMG)-based stiffness control to achieve real-time stiffness adjustment based on the user's dynamic motion. An sEMG-driven musculoskeletal model that incorporates muscle activation and muscular contraction dynamics is developed to provide reference signals for the robot's real-time stiffness control. Preliminary experiments were conducted to evaluate the system performance in tracking accuracy and comfortability, which showed the proposed rehabilitation system with sEMG-based real-time stiffness variation achieved fast adaption to the patient's dynamic movement as well as improving the comfort in robot-assisted bilateral training.
- Open Access
- 3 September 2015
- Published by MDPI AG in Micromachines
- Vol. 6 (9) , 1272-1288
Characteristic Evaluation of a Shrouded Propeller Mechanism for a Magnetic Actuated Microrobot
Medical microrobots have been widely used in clinical applications, particularly the spiral type locomotion mechanism, which was recently considered one of the main self-propelling mechanisms for the next medical microrobot to perform tasks such as capsule endoscopy and drug delivery. However, limits in clinical applications still exist. The spiral action of the microrobot while being used for diagnosis may lead to pain or even damage to the intestinal wall due to the exposed mechanisms. Therefore, a new locomotive mechanism, named the shrouded propeller mechanism, was proposed to achieve a high level of medical safety as well as effective propulsive performance in our study. The shrouded propeller mechanism consists of a bare spiral propeller and a non-rotating nozzle. To obtain a high effective propulsive performance, two types of screw grooves with different shapes including the cylindrical screw groove and the rectangular screw groove with different parameters were analyzed using the shrouded model. Two types of magnetic actuated microrobots with different driving modes, the electromagnetic (three-pole rotor) actuated microrobot and the permanent magnet (O-ring type magnet) actuated microrobot were designed to evaluate the performance of the electromagnetic actuation system. Based on experimental results, the propulsive force of the proposed magnetic actuated microrobot with a shrouded propeller was larger than the magnetic actuated microrobot with a bare spiral propeller under the same parameters. Additionally, the shrouded propeller mechanism as an actuator can be used for other medical microrobots for flexible locomotion.
- 3 September 2015
- Published by MDPI AG in Micromachines
- Vol. 6 (9) , 1272-1288
Open AccessCharacteristic Evaluation of a Shrouded Propeller Mechanism for a Magnetic Actuated Microrobot
Medical microrobots have been widely used in clinical applications, particularly the spiral type locomotion mechanism, which was recently considered one of the main self-propelling mechanisms for the next medical microrobot to perform tasks such as capsule endoscopy and drug delivery. However, limits in clinical applications still exist. The spiral action of the microrobot while being used for diagnosis may lead to pain or even damage to the intestinal wall due to the exposed mechanisms. Therefore, a new locomotive mechanism, named the shrouded propeller mechanism, was proposed to achieve a high level of medical safety as well as effective propulsive performance in our study. The shrouded propeller mechanism consists of a bare spiral propeller and a non-rotating nozzle. To obtain a high effective propulsive performance, two types of screw grooves with different shapes including the cylindrical screw groove and the rectangular screw groove with different parameters were analyzed using the shrouded model. Two types of magnetic actuated microrobots with different driving modes, the electromagnetic (three-pole rotor) actuated microrobot and the permanent magnet (O-ring type magnet) actuated microrobot were designed to evaluate the performance of the electromagnetic actuation system. Based on experimental results, the propulsive force of the proposed magnetic actuated microrobot with a shrouded propeller was larger than the magnetic actuated microrobot with a bare spiral propeller under the same parameters. Additionally, the shrouded propeller mechanism as an actuator can be used for other medical microrobots for flexible locomotion.
- 6 July 2015
- Published by Bentham Science Publishers Ltd. in Neuroscience and Biomedical Engineering
- Vol. 2 (3) , 126-131
A Blood Vessel Deformation Model Based Virtual-reality Simulator for the Robotic Catheter Operating System
Abstract: In endovascular interventional surgery, the virtual-reality (VR) simulator is critical for robotic catheter operating system since it offers physicians visual information between catheter and vessel. In spite of most VR systems using mass-spring to formulate vascular physical model, the uniform deformation doesn’t satisfy the vascular characteristics. In order to simulate the vascular deformation more vividly, we introduce standard linear solid model to formulate its physical model and determine this model’s parameters based on vascular wall elasticity analysis. In this way, the vascular physical model deforms according to vascular radius and material properties. In addition, so as to provide the vascular radius information for parameter identification process, we adopt discrete curvature estimation based on meshed triangle method in VR system. Finally, the VR simulator equipped with the parameters determined stand linear solid model is used to describe vascular deformation which is related to its radius and material characteristics.
- 6 July 2015
- Published by Bentham Science Publishers Ltd. in Neuroscience and Biomedical Engineering
- Vol. 2 (3) , 126-131
A Blood Vessel Deformation Model Based Virtual-reality Simulator for the Robotic Catheter Operating System
Abstract: In endovascular interventional surgery, the virtual-reality (VR) simulator is critical for robotic catheter operating system since it offers physicians visual information between catheter and vessel. In spite of most VR systems using mass-spring to formulate vascular physical model, the uniform deformation doesn’t satisfy the vascular characteristics. In order to simulate the vascular deformation more vividly, we introduce standard linear solid model to formulate its physical model and determine this model’s parameters based on vascular wall elasticity analysis. In this way, the vascular physical model deforms according to vascular radius and material properties. In addition, so as to provide the vascular radius information for parameter identification process, we adopt discrete curvature estimation based on meshed triangle method in VR system. Finally, the VR simulator equipped with the parameters determined stand linear solid model is used to describe vascular deformation which is related to its radius and material characteristics.
- Open Access
Design of a Novel Telerehabilitation System with a Force-Sensing Mechanism
Many stroke patients are expected to rehabilitate at home, which limits their access to proper rehabilitation equipment, treatment, or assessment by therapists. We have developed a novel telerehabilitation system that incorporates a human-upper-limb-like device and an exoskeleton device. The system is designed to provide the feeling of real therapist–patient contact via telerehabilitation. We applied the principle of a series elastic actuator to both the master and slave devices. On the master side, the therapist can operate the device in a rehabilitation center. When performing passive training, the master device can detect the therapist’s motion while controlling the deflection of elastic elements to near-zero, and the patient can receive the motion via the exoskeleton device. When performing active training, the design of the force-sensing mechanism in the master device can detect the assisting force added by the therapist. The force-sensing mechanism also allows force detection with an angle sensor. Patients’ safety is guaranteed by monitoring the motor’s current from the exoskeleton device. To compensate for any possible time delay or data loss, a torque-limiter mechanism was also designed in the exoskeleton device for patients’ safety. Finally, we successfully performed a system performance test for passive training with transmission control protocol/internet protocol communication.
Open AccessDesign of a Novel Telerehabilitation System with a Force-Sensing Mechanism
Many stroke patients are expected to rehabilitate at home, which limits their access to proper rehabilitation equipment, treatment, or assessment by therapists. We have developed a novel telerehabilitation system that incorporates a human-upper-limb-like device and an exoskeleton device. The system is designed to provide the feeling of real therapist–patient contact via telerehabilitation. We applied the principle of a series elastic actuator to both the master and slave devices. On the master side, the therapist can operate the device in a rehabilitation center. When performing passive training, the master device can detect the therapist’s motion while controlling the deflection of elastic elements to near-zero, and the patient can receive the motion via the exoskeleton device. When performing active training, the design of the force-sensing mechanism in the master device can detect the assisting force added by the therapist. The force-sensing mechanism also allows force detection with an angle sensor. Patients’ safety is guaranteed by monitoring the motor’s current from the exoskeleton device. To compensate for any possible time delay or data loss, a torque-limiter mechanism was also designed in the exoskeleton device for patients’ safety. Finally, we successfully performed a system performance test for passive training with transmission control protocol/internet protocol communication.
- Open Access
Comparison of sEMG-Based Feature Extraction and Motion Classification Methods for Upper-Limb Movement
The surface electromyography (sEMG) technique is proposed for muscle activation detection and intuitive control of prostheses or robot arms. Motion recognition is widely used to map sEMG signals to the target motions. One of the main factors preventing the implementation of this kind of method for real-time applications is the unsatisfactory motion recognition rate and time consumption. The purpose of this paper is to compare eight combinations of four feature extraction methods (Root Mean Square (RMS), Detrended Fluctuation Analysis (DFA), Weight Peaks (WP), and Muscular Model (MM)) and two classifiers (Neural Networks (NN) and Support Vector Machine (SVM)), for the task of mapping sEMG signals to eight upper-limb motions, to find out the relation between these methods and propose a proper combination to solve this issue. Seven subjects participated in the experiment and six muscles of the upper-limb were selected to record sEMG signals. The experimental results showed that NN classifier obtained the highest recognition accuracy rate (88.7%) during the training process while SVM performed better in real-time experiments (85.9%). For time consumption, SVM took less time than NN during the training process but needed more time for real-time computation. Among the four feature extraction methods, WP had the highest recognition rate for the training process (97.7%) while MM performed the best during real-time tests (94.3%). The combination of MM and NN is recommended for strict real-time applications while a combination of MM and SVM will be more suitable when time consumption is not a key requirement.
Open AccessComparison of sEMG-Based Feature Extraction and Motion Classification Methods for Upper-Limb Movement
The surface electromyography (sEMG) technique is proposed for muscle activation detection and intuitive control of prostheses or robot arms. Motion recognition is widely used to map sEMG signals to the target motions. One of the main factors preventing the implementation of this kind of method for real-time applications is the unsatisfactory motion recognition rate and time consumption. The purpose of this paper is to compare eight combinations of four feature extraction methods (Root Mean Square (RMS), Detrended Fluctuation Analysis (DFA), Weight Peaks (WP), and Muscular Model (MM)) and two classifiers (Neural Networks (NN) and Support Vector Machine (SVM)), for the task of mapping sEMG signals to eight upper-limb motions, to find out the relation between these methods and propose a proper combination to solve this issue. Seven subjects participated in the experiment and six muscles of the upper-limb were selected to record sEMG signals. The experimental results showed that NN classifier obtained the highest recognition accuracy rate (88.7%) during the training process while SVM performed better in real-time experiments (85.9%). For time consumption, SVM took less time than NN during the training process but needed more time for real-time computation. Among the four feature extraction methods, WP had the highest recognition rate for the training process (97.7%) while MM performed the best during real-time tests (94.3%). The combination of MM and NN is recommended for strict real-time applications while a combination of MM and SVM will be more suitable when time consumption is not a key requirement.