John Y. Kwon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
John Y. Kwon has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Jorge Briceno
Beth Israel Deaconess Medical Center, Boston, MA, USA
6 shared publications - Brian Timothy Velasco
Department of Orthopaedics, University of Pennsylvania, Philadelphia, Pennsylvania
5 shared publications - Mohammad Ghorbanhoseini
Beth Israel Deaconess Medical Center, Boston, MA, USA
4 shared publications - Ara Nazarian
Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
3 shared publications Christopher Miller
Beth Israel Deaconess Medical Center, Boston, MA, USA
3 shared publicationsChristopher P. Miller
Beth Israel Deaconess Medical Center, Boston, MA, United States
3 shared publications
Latest Publications
- 24 May 2025
- Published by Springer Nature
- p. 607-623
Fractures of the Talar Neck and Body
- 24 May 2025
- Published by Springer Nature
- p. 625-639
Intra-Articular Calcaneus Fractures Tips and Tricks
- 24 May 2025
- Published by Springer Nature
- p. 625-639
Intra-Articular Calcaneus Fractures Tips and Tricks
- Open Access
- 17 September 2021
- Published by Springer Nature in 3D Printing in Medicine
- Vol. 7 (1) , 1-10
3-D generated anatomic custom talar cement spacers: case reports, technical tips and literature review
Background: With today’s expanding use of total ankle arthroplasty, the ever-present trauma patient, and patients with uncontrolled comorbid conditions, surgeons face significant challenges for lower extremity reconstruction. These patients highlight some of those who may present with unique anatomy, bone loss, infection, and various other local and systemic factors that affect treatment options for successful outcomes. Three dimensional (3-D) printing for medical devices is allowing for new and customized ways to meet patient and surgeon goals of limb salvage and reconstruction. Case presentations: While the majority of 3-D printing is done for the purpose of implantation, we present a technical tip for designing a 3-D printed mold from which to create an antibiotic cement spacer for implantation. With two case illustrations including a talus fracture nonunion and infected subtalar arthrodesis nonunion, we describe the process of patient selection, implant design, fabrication, and implantation of a custom molded antibiotic cement talus. Discussion: Case illustrations present two successful limb salvage patients while giving a thorough explanation of our technique, learned tips and tricks. This applied technology builds on prior use of antibiotic cement in limb salvage of the lower extremity, most of which are joint sacrificing. 3-D printing the mold for an anatomic talus cement spacer results in a joint sparing limb salvage solution. Innovative 3-D printing technology is merged with current, pertinent literature regarding antibiotic cement to offer surgeons expanded options for temporary or definitive reconstructive techniques in some of the most challenging patients.
- 17 September 2021
- Published by Springer Nature in 3D Printing in Medicine
- Vol. 7 (1) , 1-10
Open Access3-D generated anatomic custom talar cement spacers: case reports, technical tips and literature review
Background: With today’s expanding use of total ankle arthroplasty, the ever-present trauma patient, and patients with uncontrolled comorbid conditions, surgeons face significant challenges for lower extremity reconstruction. These patients highlight some of those who may present with unique anatomy, bone loss, infection, and various other local and systemic factors that affect treatment options for successful outcomes. Three dimensional (3-D) printing for medical devices is allowing for new and customized ways to meet patient and surgeon goals of limb salvage and reconstruction. Case presentations: While the majority of 3-D printing is done for the purpose of implantation, we present a technical tip for designing a 3-D printed mold from which to create an antibiotic cement spacer for implantation. With two case illustrations including a talus fracture nonunion and infected subtalar arthrodesis nonunion, we describe the process of patient selection, implant design, fabrication, and implantation of a custom molded antibiotic cement talus. Discussion: Case illustrations present two successful limb salvage patients while giving a thorough explanation of our technique, learned tips and tricks. This applied technology builds on prior use of antibiotic cement in limb salvage of the lower extremity, most of which are joint sacrificing. 3-D printing the mold for an anatomic talus cement spacer results in a joint sparing limb salvage solution. Innovative 3-D printing technology is merged with current, pertinent literature regarding antibiotic cement to offer surgeons expanded options for temporary or definitive reconstructive techniques in some of the most challenging patients.
- 1 July 2020
- Published by Elsevier in Foot and Ankle Surgery
- Vol. 26 (5) , 573-579
Assessment of variables that influence agreement between reviewers for Foot & Ankle International
- 1 July 2020
- Published by Elsevier in Foot and Ankle Surgery
- Vol. 26 (5) , 573-579
Assessment of variables that influence agreement between reviewers for Foot & Ankle International
- 1 May 2019
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 58 (3) , 540-544
Trends in Foot and Ankle Studies Published in High-Impact General Medical Journals: A Systematic Review
- 1 May 2019
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 58 (3) , 540-544
Trends in Foot and Ankle Studies Published in High-Impact General Medical Journals: A Systematic Review