LWLukas Weiser

Lukas Weiser

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lukas Weiser has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Johannes M. Rueger

    Department of Trauma, Hand and Reconstructive Surgery, Hamburg-Eppendorf University Medical Center, Martinistrasse 52, 20246, Hamburg, Germany

    3 shared publications
  • Kay Sellenschloh

    Institute of Biomechanics, TUHH Hamburg University of Technology, Hamburg, Germany

    3 shared publications
  • Klaus Püschel

    Institute of Forensic Medicine, Hamburg-Eppendorf University Medical Center, Hamburg, Germany

    3 shared publications
  • Michael M. Morlock

    Institute of Biomechanics, Hamburg University of Technology (TUHH), Hamburg, Germany

    3 shared publications
  • Wolfgang Lehmann

    Department of Trauma, Hand and Reconstructive Surgery, Hamburg-Eppendorf University Medical Center, Martinistrasse 52, 20246, Hamburg, Germany

    3 shared publications
  • Jakob V. Nüchtern

    Department of Trauma, Hand and Reconstructive Surgery, Hamburg-Eppendorf University Medical Center, Martinistrasse 52, 20246, Hamburg, Germany

    2 shared publications

Latest Publications

  • Acromioclavicular joint dislocations: coracoclavicular reconstruction with and without additional direct acromioclavicular repair

    by Lukas Weiser, Jakob V. Nüchtern, Kay Sellenschloh, Klaus Püschel, Michael M. Morlock, Johannes M. Rueger, Michael Hoffmann, Wolfgang Lehmann, Lars G. Großterlinden

    To evaluate different stabilisation techniques for acromioclavicular (AC) joint separations, including direct AC repair, and to compare the properties of the stabilised and native joints. An established in vitro testing model for the AC joint was used to analyse joint stability after surgical reconstruction [double TightRope (DTR), DTR with AC repair (DTR + AC), single TR with AC repair (TR + AC), and PDS sling with AC repair (PDS + AC)]. Twenty-four human cadaveric shoulders were randomised by age into four testing groups. Joint stiffness was measured by applying an axial load during defined physiological ranges of motion. Similar tests were performed for the native joints, after dissecting the coracoclavicular and AC ligaments, and after surgical reconstruction. Cyclic loading was performed for 1000 cycles with 20–70 N and vertical load to failure determined after cyclic testing. Axial stiffness for all TR groups was significantly higher than for the native joint (DTR 38.94 N/mm, p = 0.005; DTR + AC 37.79 N/mm, p = 0.015; TR + AC 45.61 N/mm, p < 0.001 vs. native 26.05 N/mm). The axial stiffness of the PDS + AC group was similar to that of the native joint group (21.4 N/mm, n.s.). AC repair did not significantly influence rotational stiffness. Load to failure was similar and >600 N in all groups (n.s.). Reconstruction of AC dislocations with one or two TRs leads to stable results with a higher stiffness than the native joints. For the PDS + AC group, axial stiffness was similar to the native situation, although there might be a risk of elongation. Direct AC repair showed no significantly increased stability in comparison with reconstructions without direct AC repair. Thus, a direct AC repair seems to be dispensable in clinical practice, while TRs or PDS cerclages appear to provide sufficiently stable results.


  • Zementaugmentation an der Wirbelsäule

    by J. P. Kolb, L. Weiser, R. A. Kueny, G. Huber, J. M. Rueger, W. Lehmann

    Wirbelkörperkompressionsfrakturen sind die häufigsten osteoporoseassoziierten Frakturtypen. Seit Einführung der Zementaugmentation durch Vertebroplastie und der Augmentation von Schrauben hat sich die Versorgung osteoporotischer Frakturen wesentlich geändert. Es werden biomechanische Aspekte des Risikos von Anschlussfrakturen sowie bei der Versorgung osteoporotischer Wirbelkörperfrakturen bei der reinen Zementaugmentation durch Vertebroplastie und bei der Zementaugmentation von Schrauben bei dorsalen Instrumentationen dargestellt. In einer servohydraulischen Maschine wurden 18 humane osteoporotische Lendenwirbelsäulen (L1–5) angrenzend an zementaugmentierte Wirbelkörper getestet. Dabei wurden ein Standardzement und ein speziell für die Versuche modifizierter Zement mit einer geringeren Festigkeit verwendet. Weiterhin wurden unterschiedliche Verankerungsformen von Pedikelschrauben mit und ohne Zementaugmentation an weiteren humanen Präparaten mit einem einfachen Pull-out-Test und einem Fatique-Test, der die physiologischen Bedingungen besser widerspiegelt, geprüft. Die Zementaugmentation an der Wirbelsäule führt bei osteoporotischem Knochen zu einer höheren biomechanischen Stabilität. Die damit verbundene veränderte Steifigkeit führt jedoch zu biomechanischen Veränderungen mit dem Risiko von Anschlussfrakturen. Die Verwendung eines weniger festen Zements reduziert das Risko für Anschlussfrakturen signifikant. Beide Schraubenaugmentationstechniken zeigten eine signifikante Erhöhung der Auszugskraft gegenüber der Gruppe ohne Zement. Die Augmentation durch die Schraubenperforation ergab im Fatique-Test die höchste Stabilität. Die Zementaugmentation führt zu einer deutlichen Veränderung der biomechanischen Eigenschaften. Große Stabilitätsunterschiede zwischen den angrenzenden Wirbelkörpern erhöhen das Risiko für Anschlussfrakturen, das durch modifizierten Zement mit reduzierter Festigkeit gemindert werden kann. Spezielle, für die Zementapplikation konzipierte Schrauben zeigen im Fatique-Test die höchste Stabilität. Vertebral compression fractures are the most common osteoporotic fractures. Since the introduction of vertebroplasty and screw augmentation, the management of osteoporotic fractures has changed significantly. The biomechanical characteristics of the risk of adjacent fractures and novel treatment modalities for osteoporotic vertebral fractures, including pure cement augmentation by vertebroplasty, and cement augmentation of screws for posterior instrumentation, are explored. Eighteen human osteoporotic lumbar spines (L1–5) adjacent to vertebral bodies after vertebroplasty were tested in a servo-hydraulic machine. As augmentation compounds we used standard cement and a modified low-strength cement. Different anchoring pedicle screws were tested with and without cement augmentation in another cohort of human specimens with a simple pull-out test and a fatigue test that better reflects physiological conditions. Cement augmentation in the osteoporotic spine leads to greater biomechanical stability. However, change in vertebral stiffness resulted in alterations with the risk of adjacent fractures. By using a less firm cement compound, the risk of adjacent fractures is significantly reduced. Both screw augmentation techniques resulted in a significant increase in the withdrawal force compared with the group without cement. Augmentation using perforated screws showed the highest stability in the fatigue test. The augmentation of cement leads to a significant change in the biomechanical properties. Differences in the stability of adjacent vertebral bodies increase the risk of adjacent fractures, which could be mitigated by a modified cement compound with reduced strength. Screws that were specifically designed for cement application displayed greatest stability in the fatigue test.


  • Extra- vs. intramedullary treatment of pertrochanteric fractures: a biomechanical in vitro study comparing dynamic hip screw and intramedullary nail

    by Lukas Weiser, Andreas A. Ruppel, Jakob V. Nüchtern, Kay Sellenschloh, Johannes Zeichen, Klaus Püschel, Michael M. Morlock, Wolfgang Lehmann

    Due to the demographic trend, pertrochanteric fractures of the femur will gain increasing importance in the future. Both extra- and intramedullary implants are used with good results in the treatment of these fractures. New, angular stable extramedullary implants promise increased postoperative stability even with unstable fractures. Additional trochanteric plates are intended to prevent secondary impaction, varisation and shortening of the fracture, as well as medialisation of the femoral shaft. The aim of this study was to perform a biomechanical comparison of both procedures regarding their postoperative stability and failure mechanisms. Twelve fresh-frozen human femurs were randomized into two groups based on the volumetric bone mineral density (vBMD). Standardized pertrochanteric fractures (AO31-A2.3) were generated and treated either with an angular stable dynamic hip screw (DHS) or an intramedullary nail (nail). Correct implant position and the tip–apex distance (TAD) were controlled postoperatively using X-ray. Specimens were mounted in a servohydraulic testing machine and an axial loading was applied according to a single-leg stance model. Both groups were biomechanically compared with regard to native and postoperative stiffness, survival during cyclic testing, load to failure, and failure mechanisms. TAD, vBMD, and native stiffness were similar for both groups. The stiffness decreased significantly from native to postoperative state in all specimens (p < 0.001). The postoperative stiffness of both groups varied non-significantly (p = 0.275). The failure loads for specimens treated with the nail were significantly higher than for those treated with the DHS (8480.8 ± 1238.9 N vs. 2778.2 ± 196.8 N; p = 0.008). Extra- and intramedullary osteosynthesis showed comparable results as regards postoperative stiffness and survival during cyclic testing. Since the failure load of the nail was significantly higher in the tested AO31-A2.3 fracture model, we conclude that intramedullary implants should be preferred in these, unstable, fractures.


  • Interprothetische Frakturen

    by Lukas Weiser, Johannes M. Rueger, Wolfgang Lehmann

    Als interprothetische Fraktur bezeichnet man eine Fraktur zwischen 2 im selben Knochen einliegenden Prothesen. Aufgrund des demografischen Wandels und der zunehmenden Anzahl implantierter Endoprothesen wird die Inzidenz dieser Frakturen in Zukunft deutlich ansteigen. Primäres Ziel bei der Versorgung dieser Verletzungen ist die schnelle Wiederherstellung der Mobilität der häufig komorbiden Patienten. Die Art der Versorgung hängt in wesentlichem Ausmaß davon ab, ob die beteiligten Prothesen noch fest im Knochen verankert oder gelockert sind. Unabhängig davon ist die Behandlung kompliziert und komplikationsträchtig. Da die Biologie des Knochens häufig bereits durch die implantierten Prothesen stark beeinträchtigt ist, ist ein weichteil- sowie knochenschonendes Vorgehen essenziell. Auch aus diesem Grund ist die winkelstabile Plattenosteosynthese aktuell der Goldstandard in der Versorgung. Additive Verfahren wie die Anlagerung von autologem oder allogenem Knochen können bei schlechter Qualität des umgebenden Knochens sinnvoll sein. Sollte eine Osteosynthese aufgrund von gelockerten Prothesen oder schlechter Knochenqualität nicht möglich sein, kann ein vollständiger Femurersatz die letzte Therapieoption sein. Fractures occurring between two prostheses implanted in the same bone are called interprosthetic fractures. Due to the demographic trend and the rising number of implanted hip and knee prostheses, the incidence of these fractures is going to increase in the future. One of the main goals during treatment of these fractures is the early mobilisation of the multimorbid patients. The mode of treatment mainly depends on the fixation status of the involved prosthesis. Independently, the treatment of these fractures is demanding and subject to many complications. Since the biology of the bone has already been changed due to implantation of the prostheses in most patients, it is very important to treat bone and soft tissue thoughtfully. The angular stable osteosynthesis is the gold standard for the treatment of these fractures at the moment. Additional procedures such as transplantation of autologous or allogenous bone are useful in cases with poor bone quality. If an osteosynthesis is impossible due to loosening of the prosthesis or poor bone quality, a total femur replacement may be the last possibility for treatment.

  • Interposition sleeve as treatment option for interprosthetic fractures of the femur: a biomechanical in vitro assessment

    by Lukas Weiser, Michal A. Korecki, Kay Sellenschloh, Florian Fensky, Klaus Püschel, Michael M. Morlock, Johannes M. Rueger, Wolfgang Lehmann

    The number of patients having hip and knee arthroplasties on the ipsilateral leg is going to rise. In this regard, the prevalence of interprosthetic femoral fractures is going to increase further. The treatment of these fractures is difficult and sometimes it is impossible to perform an osteosynthesis because of worse bone quality. The goal of this study was to investigate the use of an interposition sleeve as an alternative treatment option for interprosthetic fractures with major bone loss. Six human cadaveric femurs were instrumented using cemented hip- and knee prosthesis. Interprosthetic fractures were induced during a four-point-bending test and then treated using the interposition sleeve. Afterwards the constructs were tested using the four-point-bending test again. Load-to-failure of the construct before fracturing was significantly higher than after treatment with the interposition sleeve (10681 N vs. 5083 N; p = 0.002). The failure mechanism of the femurs with the interposition sleeve was plastic deformation of the hip or knee prosthesis. The interposition sleeve did not fail in any specimen. The interposition sleeve is a valuable treatment option for interprosthetic fractures in situations in which osteosynthesis is impossible or insecure due to major bone defects. However, fracture healing should be preferred whenever possible.