Amir Tokić
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Amir Tokić has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Damir Demirovic
Faculty of Electrical Engineering, University of Tuzla, Tuzla, Bosnia and Herzegovina
2 shared publications- Izet Dzananovic
Thermal Power Plant “Tuzla”, Tuzla, Bosnia and Herzegovina
2 shared publications - Senada Avdic
Department of Physics, Faculty of Natural Sciences and Mathematics, University of Tuzla, Tuzla, Bosnia and Herzegovina
2 shared publications Suad Kunosic
Department of Physics, Faculty of Natural Sciences and Mathematics, University of Tuzla, Tuzla, Bosnia and Herzegovina
2 shared publications- Alain Xemard
Electricité de France R&D, Clamart, France
1 shared publication - Anamari Nakić
Faculty of Electrical Engineering and Computing, University of Zagreb, Zagreb, Croatia
1 shared publication
Latest Publications
- Open Access
Parameter Estimation of a Single-Phase Diode-Bridge Rectifier Under Steady-State, Load Variation, and Startup Transient Using Terminal Measurements
This paper presents a numerical framework for parameter estimation of a single-phase diode-bridge rectifier with capacitive filtering. The proposed approach integrates a state-space model of the rectifier, numerically solved using the second-order Backward Differentiation Formula (BDF2), with a derivative-free Nelder–Mead optimization algorithm. Parameter estimation is performed using only terminal voltage and current measurements, eliminating the need for explicit conduction-interval detection or direct measurement of internal circuit states. The framework is experimentally validated under three operating conditions: steady-state operation, dynamic load variation, and startup transient. Five estimation scenarios are analyzed to assess the influence of the excitation condition and the inclusion of the initial capacitor voltage as an additional unknown parameter on estimation accuracy. The results demonstrate that excitation conditions strongly influence parameter estimation accuracy. Steady-state excitation yields the largest estimation errors, particularly for the series resistance and DC-link capacitance, whereas dynamic load variation improves the estimation accuracy of several parameters. The startup transient provides the highest overall estimation accuracy, with all four estimated parameters exhibiting relative errors below 5.5%. The proposed framework provides a practical approach for parameter estimation of single-phase rectifiers using terminal measurements only and highlights the importance of the excitation condition for reliable parameter estimation. The method can support the identification and modeling of nonlinear electronic loads in power-system and power-quality studies.Open AccessParameter Estimation of a Single-Phase Diode-Bridge Rectifier Under Steady-State, Load Variation, and Startup Transient Using Terminal Measurements
This paper presents a numerical framework for parameter estimation of a single-phase diode-bridge rectifier with capacitive filtering. The proposed approach integrates a state-space model of the rectifier, numerically solved using the second-order Backward Differentiation Formula (BDF2), with a derivative-free Nelder–Mead optimization algorithm. Parameter estimation is performed using only terminal voltage and current measurements, eliminating the need for explicit conduction-interval detection or direct measurement of internal circuit states. The framework is experimentally validated under three operating conditions: steady-state operation, dynamic load variation, and startup transient. Five estimation scenarios are analyzed to assess the influence of the excitation condition and the inclusion of the initial capacitor voltage as an additional unknown parameter on estimation accuracy. The results demonstrate that excitation conditions strongly influence parameter estimation accuracy. Steady-state excitation yields the largest estimation errors, particularly for the series resistance and DC-link capacitance, whereas dynamic load variation improves the estimation accuracy of several parameters. The startup transient provides the highest overall estimation accuracy, with all four estimated parameters exhibiting relative errors below 5.5%. The proposed framework provides a practical approach for parameter estimation of single-phase rectifiers using terminal measurements only and highlights the importance of the excitation condition for reliable parameter estimation. The method can support the identification and modeling of nonlinear electronic loads in power-system and power-quality studies. - 24 April 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (5) , 264
Uncovering patterns and distribution of severity indicators of empirical blackouts events
- 24 April 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (5) , 264
Uncovering patterns and distribution of severity indicators of empirical blackouts events
- 17 November 2025
- Published by Springer Nature in Journal of Computational Electronics
- Vol. 25 (1) , 14
Novel approach for estimation of light-emitting diode lamp parameters based on hybrid metaheuristic algorithms
- 17 November 2025
- Published by Springer Nature in Journal of Computational Electronics
- Vol. 25 (1) , 14
Novel approach for estimation of light-emitting diode lamp parameters based on hybrid metaheuristic algorithms
- Open Access
- 7 October 2025
- Published by Springer Nature in Research Square
Uncovering patterns and distribution of severity indicators of empirical blackouts events
This paper deals with a time series of blackout events of the power transmission system in the Federation of Bosnia and Herzegovina (FB&H) in the period 2015–2024 and probability distributions that best fit these empirical data. The present study is focused on global behaviour and dynamics of time series ignoring the details of particular failures. We compiled the first blackouts database in FB&H including the relevant information on each blackout feature. The power law behaviour of the transmission network failure events in the FB&H power grid depending on their severity was identified. The results of this study show that the time intervals between the blackout events follow the exponential distribution. The data available from the FB&H power grid transmission centres in the observed period indicate that the frequency of all the blackout events in FB&H is not decreasing. It was determined that blackout probability increases substantially during the morning hours while the number of blackout events increases during the early summer and mid-fall months. However, the correlation analysis results show that there is only a weak, statistically insignificant correlation between event size and restoration time. The results of this study provide a set of unique and valuable insights to operators and decision makers for the safe operation of the FB&H power system. The broader scope of applications of the results obtained includes the connection of the FB&H power system to power distribution across the Balkans for transfers and trading. A dominant source of electricity in B&H is thermal power plant (about 65%) and it was of interest to perform an investigation into whether a dominant source of electricity impacts the blackout size distribution. It was demonstrated that the dominant type of electricity source does not have a significant effect on the alpha exponent of power law distribution.
- 7 October 2025
- Published by Springer Nature in Research Square
Open AccessUncovering patterns and distribution of severity indicators of empirical blackouts events
This paper deals with a time series of blackout events of the power transmission system in the Federation of Bosnia and Herzegovina (FB&H) in the period 2015–2024 and probability distributions that best fit these empirical data. The present study is focused on global behaviour and dynamics of time series ignoring the details of particular failures. We compiled the first blackouts database in FB&H including the relevant information on each blackout feature. The power law behaviour of the transmission network failure events in the FB&H power grid depending on their severity was identified. The results of this study show that the time intervals between the blackout events follow the exponential distribution. The data available from the FB&H power grid transmission centres in the observed period indicate that the frequency of all the blackout events in FB&H is not decreasing. It was determined that blackout probability increases substantially during the morning hours while the number of blackout events increases during the early summer and mid-fall months. However, the correlation analysis results show that there is only a weak, statistically insignificant correlation between event size and restoration time. The results of this study provide a set of unique and valuable insights to operators and decision makers for the safe operation of the FB&H power system. The broader scope of applications of the results obtained includes the connection of the FB&H power system to power distribution across the Balkans for transfers and trading. A dominant source of electricity in B&H is thermal power plant (about 65%) and it was of interest to perform an investigation into whether a dominant source of electricity impacts the blackout size distribution. It was demonstrated that the dominant type of electricity source does not have a significant effect on the alpha exponent of power law distribution.
- Open Access
- 1 February 2025
- Published by International Council on Large Electric Systems - Cigre, Croatian National Committee in Journal of Energy - Energija
- Vol. 74 (1) , 9-12
Arc Flash Calculation for 110/20 kV HV/MV Substation
This paper presents arc flash calculation for 110/20 kV HV/MV substation that follows IEEE 1584:2018 Standard. The IEEE 1584:2018 standard has been completely revised compared to the IEEE 1584:2002 standard, and according to the IEEE 1584:2002 standard, the calculation of an electric arc can no longer be performed. The paper shows how calculating the risk assessment to identify potential electrical hazards and implement appropriate safety measures and ultimately to protect workers from arc-flash hazards. Arc flash calculation for the case of real 110/20 kV substation is shown.
- 1 February 2025
- Published by International Council on Large Electric Systems - Cigre, Croatian National Committee in Journal of Energy - Energija
- Vol. 74 (1) , 9-12
Open AccessArc Flash Calculation for 110/20 kV HV/MV Substation
This paper presents arc flash calculation for 110/20 kV HV/MV substation that follows IEEE 1584:2018 Standard. The IEEE 1584:2018 standard has been completely revised compared to the IEEE 1584:2002 standard, and according to the IEEE 1584:2002 standard, the calculation of an electric arc can no longer be performed. The paper shows how calculating the risk assessment to identify potential electrical hazards and implement appropriate safety measures and ultimately to protect workers from arc-flash hazards. Arc flash calculation for the case of real 110/20 kV substation is shown.
- 3 January 2021
- Published by Springer Nature in Electrical Engineering
- Vol. 103 (3) , 1321-1333
Determination of single-phase transformer saturation characteristic by using Nelder–Mead optimization method
- 3 January 2021
- Published by Springer Nature in Electrical Engineering
- Vol. 103 (3) , 1321-1333
Determination of single-phase transformer saturation characteristic by using Nelder–Mead optimization method
- Open Access
- 11 September 2013
- Published by Hindawi Limited in Mathematical Problems in Engineering
- Vol. 2013, 1-10
Simulations of Transformer Inrush Current by Using BDF-Based Numerical Methods
This paper describes three different ways of transformer modeling for inrush current simulations. The developed transformer models are not dependent on an integration step, thus they can be incorporated in a state-space form of stiff differential equation systems. The eigenvalue propagations during simulation time cause very stiff equation systems. The state-space equation systems are solved by usingA- andL-stable numerical differentiation formulas (NDF2) method. This method suppresses spurious numerical oscillations in the transient simulations. The comparisons between measured and simulated inrush and steady-state transformer currents are done for all three of the proposed models. The realized nonlinear inductor, nonlinear resistor, and hysteresis model can be incorporated in the EMTP-type programs by using a combination of existing trapezoidal and proposed NDF2 methods.
- 11 September 2013
- Published by Hindawi Limited in Mathematical Problems in Engineering
- Vol. 2013, 1-10
Open AccessSimulations of Transformer Inrush Current by Using BDF-Based Numerical Methods
This paper describes three different ways of transformer modeling for inrush current simulations. The developed transformer models are not dependent on an integration step, thus they can be incorporated in a state-space form of stiff differential equation systems. The eigenvalue propagations during simulation time cause very stiff equation systems. The state-space equation systems are solved by usingA- andL-stable numerical differentiation formulas (NDF2) method. This method suppresses spurious numerical oscillations in the transient simulations. The comparisons between measured and simulated inrush and steady-state transformer currents are done for all three of the proposed models. The realized nonlinear inductor, nonlinear resistor, and hysteresis model can be incorporated in the EMTP-type programs by using a combination of existing trapezoidal and proposed NDF2 methods.
- 1 January 2012
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 45 (2) , 1254-1259
Measurement, Modeling and Simulation of Capacitor Bank Switching Transients
- 1 January 2012
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 45 (2) , 1254-1259
Measurement, Modeling and Simulation of Capacitor Bank Switching Transients