Arturo B. Ramirez
Arturo B. Ramirez has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Eric P. Kaldjian
RareCyte, Inc
2 shared publications - Jackie L. Stilwell
RareCyte, Inc., Seattle, WA, USA
2 shared publications - Aadel A. Chaudhuri
Department of Radiation Oncology, Mayo Clinic, Rochester, MN, USA.
1 shared publication - Agostina Nardone
Department of Medical Oncology, Dana-Farber Cancer Institute, Harvard Medical School, Boston, Massachusetts
1 shared publication - Alisa C Clein
Departments of Laboratory Medicine and Medicine, University of Washington, Washington, USA
1 shared publication - Amanda Miller
Center for Biomedical Informatics, Department of Health Management and Informatics, School of Medicine, University of Missouri, Columbia, MO 65212, USA
1 shared publication
Latest Publications
- 3 June 2026
- Published by Springer Nature
- Vol. 2999, 137-152
Characterization of Circulating Tumor Cells and Other Rare Cells in Blood Using the RareCyte Platform
Rare cell populations in blood are of high research and diagnostic interest. The RareCyte platform is an end-to-end technology solution from sample collection to fluorescence imaging-based detection and characterization of rare cells from whole blood samples. The benefits of the platform include ease of use, robust repeatability, automated staining using validated protocols and reagent kits, post-collection stability of blood samples, long-term storage of processed slide smears before testing, high-sensitivity detection of rare cells, dual-biomarker phenotypic characterization of rare cells, single rare cell isolation for molecular analysis, and flexibility to detect non-epithelial cells of interest in circulation. For this volume, we will focus on circulating tumor cells (CTCs) as exemplar rare cells for analysis. The workflow begins by collecting blood samples into AccuCyte® blood collection tubes (BCTs). These BCTs stabilize the blood and its components for at least 7 days, at room temperature, thus enabling a sample to be shipped from the draw site to a laboratory anywhere in the world for processing onto microscope slides. The AccuCyte sample preparation process uses density-based separation to comprehensively collect the nucleated cell fraction (buffy coat) of the blood and spread it as an adherent monolayer onto microscope slides. At this point, the sample can be frozen for long-term storage and banked for at least three years before testing. As an additional product of the sample processing workflow, high-purity plasma containing cell-free DNA (cfDNA) is isolated from the same sample and can be used to measure circulating tumor DNA (ctDNA). Slide staining is performed using automated instruments, which utilize immunofluorescent reagents to detect markers that allow CTC enumeration and measurement of biomarker expression on CTCs. The stained slides are scanned on CyteFinder® instruments, which use high-speed, high-resolution optics to scan the slides to detect and quantify protein expression on CTCs. A machine learning-based algorithm processes the images and presents high-confidence objects of interest for a reviewer to confirm as CTCs. After the CTC has been confirmed, its expression of up to two biomarkers of interest can be quantified and reported. CTCs can also be isolated from the slides using a semi-automated single cell picker called CytePicker®, which uses a precision-controlled 25 µm needle tip to remove the cell physically from the slide and deposit it into a PCR tube for molecular characterization of DNA or RNA via next-generation sequencing. This comprehensive, reliable, imaged-based CTC platform is being utilized in global clinical trials ranging from early pharmacodynamic studies to drug-target/effector quantitation in human subjects.
- 3 June 2026
- Published by Springer Nature
- Vol. 2999, 137-152
Characterization of Circulating Tumor Cells and Other Rare Cells in Blood Using the RareCyte Platform
Rare cell populations in blood are of high research and diagnostic interest. The RareCyte platform is an end-to-end technology solution from sample collection to fluorescence imaging-based detection and characterization of rare cells from whole blood samples. The benefits of the platform include ease of use, robust repeatability, automated staining using validated protocols and reagent kits, post-collection stability of blood samples, long-term storage of processed slide smears before testing, high-sensitivity detection of rare cells, dual-biomarker phenotypic characterization of rare cells, single rare cell isolation for molecular analysis, and flexibility to detect non-epithelial cells of interest in circulation. For this volume, we will focus on circulating tumor cells (CTCs) as exemplar rare cells for analysis. The workflow begins by collecting blood samples into AccuCyte® blood collection tubes (BCTs). These BCTs stabilize the blood and its components for at least 7 days, at room temperature, thus enabling a sample to be shipped from the draw site to a laboratory anywhere in the world for processing onto microscope slides. The AccuCyte sample preparation process uses density-based separation to comprehensively collect the nucleated cell fraction (buffy coat) of the blood and spread it as an adherent monolayer onto microscope slides. At this point, the sample can be frozen for long-term storage and banked for at least three years before testing. As an additional product of the sample processing workflow, high-purity plasma containing cell-free DNA (cfDNA) is isolated from the same sample and can be used to measure circulating tumor DNA (ctDNA). Slide staining is performed using automated instruments, which utilize immunofluorescent reagents to detect markers that allow CTC enumeration and measurement of biomarker expression on CTCs. The stained slides are scanned on CyteFinder® instruments, which use high-speed, high-resolution optics to scan the slides to detect and quantify protein expression on CTCs. A machine learning-based algorithm processes the images and presents high-confidence objects of interest for a reviewer to confirm as CTCs. After the CTC has been confirmed, its expression of up to two biomarkers of interest can be quantified and reported. CTCs can also be isolated from the slides using a semi-automated single cell picker called CytePicker®, which uses a precision-controlled 25 µm needle tip to remove the cell physically from the slide and deposit it into a PCR tube for molecular characterization of DNA or RNA via next-generation sequencing. This comprehensive, reliable, imaged-based CTC platform is being utilized in global clinical trials ranging from early pharmacodynamic studies to drug-target/effector quantitation in human subjects.
- Open Access
- 2 February 2022
- Published by MDPI AG in Current Issues in Molecular Biology
- Vol. 44 (2) , 750-763
Single Circulating-Tumor-Cell-Targeted Sequencing to Identify Somatic Variants in Liquid Biopsies in Non-Small-Cell Lung Cancer Patients
Non-small-cell lung cancer (NSCLC) accounts for most cancer-related deaths worldwide. Liquid biopsy by a blood draw to detect circulating tumor cells (CTCs) is a tool for molecular profiling of cancer using single-cell and next-generation sequencing (NGS) technologies. The aim of the study was to identify somatic variants in single CTCs isolated from NSCLC patients by targeted NGS. Thirty-one subjects (20 NSCLC patients, 11 smokers without cancer) were enrolled for blood draws (7.5 mL). CTCs were identified by immunofluorescence, individually retrieved, and DNA-extracted. Targeted NGS was performed to detect somatic variants (single-nucleotide variants (SNVs) and insertions/deletions (Indels)) across 65 oncogenes and tumor suppressor genes. Cancer-associated variants were classified using OncoKB database. NSCLC patients had significantly higher CTC counts than control smokers (p = 0.0132; Mann–Whitney test). Analyzing 23 CTCs and 13 white blood cells across seven patients revealed a total of 644 somatic variants that occurred in all CTCs within the same subject, ranging from 1 to 137 per patient. The highest number of variants detected in ≥1 CTC within a patient was 441. A total of 18/65 (27.7%) genes were highly mutated. Mutations with oncogenic impact were identified in functional domains of seven oncogenes/tumor suppressor genes (NF1, PTCH1, TP53, SMARCB1, SMAD4, KRAS, and ERBB2). Single CTC-targeted NGS detects heterogeneous and shared mutational signatures within and between NSCLC patients. CTC single-cell genomics have potential for integration in NSCLC precision oncology.
- 2 February 2022
- Published by MDPI AG in Current Issues in Molecular Biology
- Vol. 44 (2) , 750-763
Open AccessSingle Circulating-Tumor-Cell-Targeted Sequencing to Identify Somatic Variants in Liquid Biopsies in Non-Small-Cell Lung Cancer Patients
Non-small-cell lung cancer (NSCLC) accounts for most cancer-related deaths worldwide. Liquid biopsy by a blood draw to detect circulating tumor cells (CTCs) is a tool for molecular profiling of cancer using single-cell and next-generation sequencing (NGS) technologies. The aim of the study was to identify somatic variants in single CTCs isolated from NSCLC patients by targeted NGS. Thirty-one subjects (20 NSCLC patients, 11 smokers without cancer) were enrolled for blood draws (7.5 mL). CTCs were identified by immunofluorescence, individually retrieved, and DNA-extracted. Targeted NGS was performed to detect somatic variants (single-nucleotide variants (SNVs) and insertions/deletions (Indels)) across 65 oncogenes and tumor suppressor genes. Cancer-associated variants were classified using OncoKB database. NSCLC patients had significantly higher CTC counts than control smokers (p = 0.0132; Mann–Whitney test). Analyzing 23 CTCs and 13 white blood cells across seven patients revealed a total of 644 somatic variants that occurred in all CTCs within the same subject, ranging from 1 to 137 per patient. The highest number of variants detected in ≥1 CTC within a patient was 441. A total of 18/65 (27.7%) genes were highly mutated. Mutations with oncogenic impact were identified in functional domains of seven oncogenes/tumor suppressor genes (NF1, PTCH1, TP53, SMARCB1, SMAD4, KRAS, and ERBB2). Single CTC-targeted NGS detects heterogeneous and shared mutational signatures within and between NSCLC patients. CTC single-cell genomics have potential for integration in NSCLC precision oncology.
- Open Access
- 12 March 2019
- Published by Springer Nature in BMC Cancer
- Vol. 19 (1) , 220
Circulating tumor cell investigation in breast cancer patient-derived xenograft models by automated immunofluorescence staining, image acquisition, and single cell retrieval and analysis
Breast cancer patient-derived xenograft (BC-PDX) models represent a continuous and reproducible source of circulating tumor cells (CTCs) for studying their role in tumor biology and metastasis. We have previously shown the utility of BC-PDX models in the study of CTCs by immunohistochemistry (IHC) on serial paraffin sections and manual microscopic identification of cytokeratin-positive cells, a method that is both low-throughput and labor-intensive. We therefore aimed to identify and characterize CTCs from small volume mouse blood samples and examined its practical workflow in a study of BC-PDX mice treated with chemotherapy using an automated imaging platform, the AccuCyte®–CyteFinder® system. CTC analysis was conducted using blood from non-tumor bearing SCID/Beige mice spiked with human breast cancer cells, BC-PDX-bearing mice, and BC-PDX mice treated with vehicle or chemotherapeutic agent(s). After red blood cell lysis, nucleated cells were mixed with transfer solution, processed onto microscope slides, and stained by immunofluorescence. The CyteFinder automated scanning microscope was used to identify CTCs, defined as nucleated cells that were human cytokeratin-positive, and mouse CD45-negative. Disaggregated primary BC-PDX tumors and lung metastatic nodules were processed using the same immunostaining protocol. Collective expression of breast cancer cell surface markers (EpCAM, EGFR, and HER2) using a cocktail of target-specific antibodies was assessed. CTCs and disaggregated tumor cells were individually retrieved from slides using the CytePicker® module for sequence analysis of a BC-PDX tumor-specific PIK3CA mutation. The recovery rate of human cancer cells spiked into murine blood was 83 ± 12%. CTC detection was not significantly different from the IHC method. One-third of CTCs did not stain positive for cell surface markers. A PIK3CA T1035A mutation present in a BC-PDX tumor was confirmed in isolated single CTCs and cells from dissociated metastatic nodules after whole genome amplification and sequencing. CTC evaluation could be simply implemented into a preclinical PDX therapeutic study setting with substantial improvements in workflow over the IHC method. Analysis of small volume blood samples from BC-PDX-bearing mice using the AccuCyte–CyteFinder system allows investigation of the role of CTCs in tumor biology and metastasis independent of surface marker expression.
- 12 March 2019
- Published by Springer Nature in BMC Cancer
- Vol. 19 (1) , 220
Open AccessCirculating tumor cell investigation in breast cancer patient-derived xenograft models by automated immunofluorescence staining, image acquisition, and single cell retrieval and analysis
Breast cancer patient-derived xenograft (BC-PDX) models represent a continuous and reproducible source of circulating tumor cells (CTCs) for studying their role in tumor biology and metastasis. We have previously shown the utility of BC-PDX models in the study of CTCs by immunohistochemistry (IHC) on serial paraffin sections and manual microscopic identification of cytokeratin-positive cells, a method that is both low-throughput and labor-intensive. We therefore aimed to identify and characterize CTCs from small volume mouse blood samples and examined its practical workflow in a study of BC-PDX mice treated with chemotherapy using an automated imaging platform, the AccuCyte®–CyteFinder® system. CTC analysis was conducted using blood from non-tumor bearing SCID/Beige mice spiked with human breast cancer cells, BC-PDX-bearing mice, and BC-PDX mice treated with vehicle or chemotherapeutic agent(s). After red blood cell lysis, nucleated cells were mixed with transfer solution, processed onto microscope slides, and stained by immunofluorescence. The CyteFinder automated scanning microscope was used to identify CTCs, defined as nucleated cells that were human cytokeratin-positive, and mouse CD45-negative. Disaggregated primary BC-PDX tumors and lung metastatic nodules were processed using the same immunostaining protocol. Collective expression of breast cancer cell surface markers (EpCAM, EGFR, and HER2) using a cocktail of target-specific antibodies was assessed. CTCs and disaggregated tumor cells were individually retrieved from slides using the CytePicker® module for sequence analysis of a BC-PDX tumor-specific PIK3CA mutation. The recovery rate of human cancer cells spiked into murine blood was 83 ± 12%. CTC detection was not significantly different from the IHC method. One-third of CTCs did not stain positive for cell surface markers. A PIK3CA T1035A mutation present in a BC-PDX tumor was confirmed in isolated single CTCs and cells from dissociated metastatic nodules after whole genome amplification and sequencing. CTC evaluation could be simply implemented into a preclinical PDX therapeutic study setting with substantial improvements in workflow over the IHC method. Analysis of small volume blood samples from BC-PDX-bearing mice using the AccuCyte–CyteFinder system allows investigation of the role of CTCs in tumor biology and metastasis independent of surface marker expression.
- Open Access
- 6 May 2015
- Published by Springer Nature in BMC Cancer
- Vol. 15 (1) , 1-13
High-recovery visual identification and single-cell retrieval of circulating tumor cells for genomic analysis using a dual-technology platform integrated with automated immunofluorescence staining
Circulating tumor cells (CTCs) are malignant cells that have migrated from solid cancers into the blood, where they are typically present in rare numbers. There is great interest in using CTCs to monitor response to therapies, to identify clinically actionable biomarkers, and to provide a non-invasive window on the molecular state of a tumor. Here we characterize the performance of the AccuCyte® – CyteFinder® system, a comprehensive, reproducible and highly sensitive platform for collecting, identifying and retrieving individual CTCs from microscopic slides for molecular analysis after automated immunofluorescence staining for epithelial markers. All experiments employed a density-based cell separation apparatus (AccuCyte) to separate nucleated cells from the blood and transfer them to microscopic slides. After staining, the slides were imaged using a digital scanning microscope (CyteFinder). Precisely counted model CTCs (mCTCs) from four cancer cell lines were spiked into whole blood to determine recovery rates. Individual mCTCs were removed from slides using a single-cell retrieval device (CytePicker™) for whole genome amplification and subsequent analysis by PCR and Sanger sequencing, whole exome sequencing, or array-based comparative genomic hybridization. Clinical CTCs were evaluated in blood samples from patients with different cancers in comparison with the CellSearch® system. AccuCyte – CyteFinder presented high-resolution images that allowed identification of mCTCs by morphologic and phenotypic features. Spike-in mCTC recoveries were between 90 and 91%. More than 80% of single-digit spike-in mCTCs were identified and even a single cell in 7.5 mL could be found. Analysis of single SKBR3 mCTCs identified presence of a known TP53 mutation by both PCR and whole exome sequencing, and confirmed the reported karyotype of this cell line. Patient sample CTC counts matched or exceeded CellSearch CTC counts in a small feasibility cohort. The AccuCyte – CyteFinder system is a comprehensive and sensitive platform for identification and characterization of CTCs that has been applied to the assessment of CTCs in cancer patient samples as well as the isolation of single cells for genomic analysis. It thus enables accurate non-invasive monitoring of CTCs and evolving cancer biology for personalized, molecularly-guided cancer treatment.
- 6 May 2015
- Published by Springer Nature in BMC Cancer
- Vol. 15 (1) , 1-13
Open AccessHigh-recovery visual identification and single-cell retrieval of circulating tumor cells for genomic analysis using a dual-technology platform integrated with automated immunofluorescence staining
Circulating tumor cells (CTCs) are malignant cells that have migrated from solid cancers into the blood, where they are typically present in rare numbers. There is great interest in using CTCs to monitor response to therapies, to identify clinically actionable biomarkers, and to provide a non-invasive window on the molecular state of a tumor. Here we characterize the performance of the AccuCyte® – CyteFinder® system, a comprehensive, reproducible and highly sensitive platform for collecting, identifying and retrieving individual CTCs from microscopic slides for molecular analysis after automated immunofluorescence staining for epithelial markers. All experiments employed a density-based cell separation apparatus (AccuCyte) to separate nucleated cells from the blood and transfer them to microscopic slides. After staining, the slides were imaged using a digital scanning microscope (CyteFinder). Precisely counted model CTCs (mCTCs) from four cancer cell lines were spiked into whole blood to determine recovery rates. Individual mCTCs were removed from slides using a single-cell retrieval device (CytePicker™) for whole genome amplification and subsequent analysis by PCR and Sanger sequencing, whole exome sequencing, or array-based comparative genomic hybridization. Clinical CTCs were evaluated in blood samples from patients with different cancers in comparison with the CellSearch® system. AccuCyte – CyteFinder presented high-resolution images that allowed identification of mCTCs by morphologic and phenotypic features. Spike-in mCTC recoveries were between 90 and 91%. More than 80% of single-digit spike-in mCTCs were identified and even a single cell in 7.5 mL could be found. Analysis of single SKBR3 mCTCs identified presence of a known TP53 mutation by both PCR and whole exome sequencing, and confirmed the reported karyotype of this cell line. Patient sample CTC counts matched or exceeded CellSearch CTC counts in a small feasibility cohort. The AccuCyte – CyteFinder system is a comprehensive and sensitive platform for identification and characterization of CTCs that has been applied to the assessment of CTCs in cancer patient samples as well as the isolation of single cells for genomic analysis. It thus enables accurate non-invasive monitoring of CTCs and evolving cancer biology for personalized, molecularly-guided cancer treatment.