Michaela M. Hell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michaela M. Hell has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Stephan Achenbach
Medizinische Klinik 2, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Deutschland
5 shared publications Annika Schuhbaeck
Department of Cardiology, Faculty of Medicine, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Ulmenweg 18, 91054 Erlangen, Germany
4 shared publicationsMohamed Marwan
Department of Cardiology, Faculty of Medicine, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Ulmenweg 18, 91054 Erlangen, Germany
4 shared publicationsStephan Achenbach
Department of Cardiology, Faculty of Medicine, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Ulmenweg 18, 91054 Erlangen, Germany
3 shared publications- Damini Dey
Cedars-Sinai Medical Center, Los Angeles, CA, United States
2 shared publications Lukas Biburger
Department of Cardiology, Faculty of Medicine, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Ulmenweg 18, 91054 Erlangen, Germany
2 shared publications
Latest Publications
- 1 December 2019
- Published by Elsevier in European Journal of Radiology
- Vol. 121, 108732
Quantification of epicardial adipose tissue by cardiac CT: Influence of acquisition parameters and contrast enhancement
- 1 December 2019
- Published by Elsevier in European Journal of Radiology
- Vol. 121, 108732
Quantification of epicardial adipose tissue by cardiac CT: Influence of acquisition parameters and contrast enhancement
- 11 March 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1098) , 20180707
CT support of cardiac structural interventions
Due to its high temporal and isotropic spatial resolution, CT has become firmly established for pre-procedural imaging in the context of structural heart disease interventions. CT allows ...
- 11 March 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1098) , 20180707
CT support of cardiac structural interventions
Due to its high temporal and isotropic spatial resolution, CT has become firmly established for pre-procedural imaging in the context of structural heart disease interventions. CT allows ...
- 26 July 2016
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 18 (8) , 906-914
Prediction of fluoroscopic angulations for transcatheter aortic valve implantation by CT angiography: influence on procedural parameters
Repeated angiograms to achieve an exactly orthogonal visualization of the aortic valve plane can substantially contribute to the total contrast amount required for transcatheter aortic valve implantation (TAVI). We investigated whether pre-procedural identification of an optimal fluoroscopic projection by cardiac computed tomography (CT) can significantly reduce the amount of a procedure-related contrast agent compared with angiographic determination of suitable angulations. Eighty consecutive patients (81 ± 5 years, 55% male) with symptomatic severe aortic valve stenosis and normal renal function who underwent cardiac CT prior to TAVI were prospectively randomized. In 40 patients, a CT-predicted suitable angulation was used for the first aortic angiogram (CT cohort); in the other 40 patients, the first aortogram was acquired at LAO 10°/cranial 10 (angiography cohort). Additional aortograms were performed if no satisfactory view of the aortic valve plane was obtained. The number of aortograms needed to achieve a satisfactory fluoroscopic projection (1.2 ± 0.6 vs. 3.2 ± 1.7; P < 0.001) and the total amount of contrast agent per TAVI procedure were significantly lower in the CT cohort (95 ± 21 vs. 125 ± 36 mL; P < 0.001). Incidence of acute kidney injury was not significantly different. There was no significant difference regarding radiation dose, time of procedure, degree of post-procedural aortic regurgitation, complications and 30-day mortality between the cohorts. Pre-procedural identification of a suitable fluoroscopic projection by cardiac CT significantly reduces a procedural contrast agent volume required for TAVI.
- 26 July 2016
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 18 (8) , 906-914
Prediction of fluoroscopic angulations for transcatheter aortic valve implantation by CT angiography: influence on procedural parameters
Repeated angiograms to achieve an exactly orthogonal visualization of the aortic valve plane can substantially contribute to the total contrast amount required for transcatheter aortic valve implantation (TAVI). We investigated whether pre-procedural identification of an optimal fluoroscopic projection by cardiac computed tomography (CT) can significantly reduce the amount of a procedure-related contrast agent compared with angiographic determination of suitable angulations. Eighty consecutive patients (81 ± 5 years, 55% male) with symptomatic severe aortic valve stenosis and normal renal function who underwent cardiac CT prior to TAVI were prospectively randomized. In 40 patients, a CT-predicted suitable angulation was used for the first aortic angiogram (CT cohort); in the other 40 patients, the first aortogram was acquired at LAO 10°/cranial 10 (angiography cohort). Additional aortograms were performed if no satisfactory view of the aortic valve plane was obtained. The number of aortograms needed to achieve a satisfactory fluoroscopic projection (1.2 ± 0.6 vs. 3.2 ± 1.7; P < 0.001) and the total amount of contrast agent per TAVI procedure were significantly lower in the CT cohort (95 ± 21 vs. 125 ± 36 mL; P < 0.001). Incidence of acute kidney injury was not significantly different. There was no significant difference regarding radiation dose, time of procedure, degree of post-procedural aortic regurgitation, complications and 30-day mortality between the cohorts. Pre-procedural identification of a suitable fluoroscopic projection by cardiac CT significantly reduces a procedural contrast agent volume required for TAVI.
- 1 March 2016
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 10 (2) , e10-e11
Prediction of fluoroscopic angulation for transcatheter aortic valve implantation by CT angiography: Influence on procedural parameters
- 1 March 2016
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 10 (2) , e10-e11
Prediction of fluoroscopic angulation for transcatheter aortic valve implantation by CT angiography: Influence on procedural parameters
- 1 March 2016
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 10 (2) , 141-149
Epicardial adipose tissue volume but not density is an independent predictor for myocardial ischemia
- 1 March 2016
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 10 (2) , 141-149
Epicardial adipose tissue volume but not density is an independent predictor for myocardial ischemia
- 1 January 2016
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 10 (1) , 52-60
CT-based analysis of pericoronary adipose tissue density: Relation to cardiovascular risk factors and epicardial adipose tissue volume
- 1 January 2016
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 10 (1) , 52-60
CT-based analysis of pericoronary adipose tissue density: Relation to cardiovascular risk factors and epicardial adipose tissue volume
- 1 August 2015
- Published by Elsevier in European Journal of Radiology
- Vol. 84 (8) , 1502-1508
Non-invasive prediction of hemodynamically significant coronary artery stenoses by contrast density difference in coronary CT angiography
- 1 August 2015
- Published by Elsevier in European Journal of Radiology
- Vol. 84 (8) , 1502-1508
Non-invasive prediction of hemodynamically significant coronary artery stenoses by contrast density difference in coronary CT angiography
- 1 November 2014
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 8 (6) , 418-425
Prospectively ECG-triggered high-pitch coronary angiography with third-generation dual-source CT at 70 kVp tube voltage: Feasibility, image quality, radiation dose, and effect of iterative reconstruction
- 1 November 2014
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 8 (6) , 418-425
Prospectively ECG-triggered high-pitch coronary angiography with third-generation dual-source CT at 70 kVp tube voltage: Feasibility, image quality, radiation dose, and effect of iterative reconstruction