SVS. Veerabuthiran

S. Veerabuthiran

*This is an algorithmically generated author record based on publicly available information.

S. Veerabuthiran has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design Analysis of Mid IR DIAL System for Detection of Hazardous Chemical Species

    by M K Jindal, S Veerabuthiran, Atul Kumar

    Nowadays, both military and public agencies are concerned with the remote detection of toxic gases and chemical warfare agents in the atmosphere. A promising method for the remote detection of such harmful chemicals in the atmosphere is Differential Absorption Lidar (DIAL). In the current paper, system design analysis has been carried out to build a DIAL system for the detection of toxic chemical warfare agents, chemical warfare simulants, explosive precursors, and pollutants. The proposed DIAL system comprises an Optical Parametric Oscillator (OPO) based tuneable laser, a 203 mm diameter Cassegrain telescope, a TE-cooled MCT detector, suitable data acquisition hardware, etc. The DIAL output parameters like return signals, SNR, and minimum measurable concentrations have been simulated under different weather conditions such as clear sky, moderately hazy sky, and hazy atmospheric conditions for given system input parameters (pulse energy, detectivity, bandwidth, DAQ resolution, etc.). We have considered chemicals such as Sarin, Thiodiglycol (TDG), acetone, and methane to be detected using the system. Analysis has been carried out for these chemicals present at different locations with varying concentrations. Our analysis reveals that the DIAL system with a laser transmitter of 5 mJ energy and 203 mm receiver telescope is capable of detecting a few ppm concentrations of toxic chemicals present anywhere between the ranges from a few tens of meters to 2 km with topographic target present. The sensitivity of the system in terms of minimum detectable concentrations for the considered chemicals is also estimated for different atmospheric conditions. It is seen that the minimum detectable concentration of TDG is 3.2 ppm in clear weather conditions which increases to 9.2 ppm under a hazy atmosphere. A similar analysis has been carried out for other toxic chemicals and has been discussed in the paper.


  • Differential absorption lidar data acquisition and control system for remote detection of trace chemicals including methane and thiodiglycol

    by M. K. Jindal, M. Mainuddin, S. Veerabuthiran

    We report the design and development of a data acquisition and control system for high-speed acquisition of weak, backscattered differential signals and synchronized sequential operation of all subsystems of a tunable, mid-infrared Differential Absorption Lidar (DIAL) system. The presence of a low-level concentration of chemical species results in weak differential return signals. The differential signal also varies dynamically with respect to background atmospheric conditions. The challenge is to measure this low level of differential signal with high resolution and also control the sequence of operation of subsystems such as lasers and scanners for real time testing and evaluation in open field conditions. The concentration spread of the chemical species varies rapidly with distance. In order to capture this spatial variation, the lidar signal should be sampled and digitized at a high sampling rate. A customized Peripheral Component Interconnect based data acquisition of a 12-bit resolution, 30 Mega samples per second sampling rate, and an industrial personal computer-based control system has been realized. Detection algorithms and the firing sequence of the laser have been developed indigenously and implemented in the LabVIEW platform. The developed graphical user interface has various modes of operation as per user requirement and is capable of executing automatic operations for the developed DIAL system in order to detect and identify the chemicals. The performance has been evaluated by detecting the chemical species thiodiglycol at 800 m using 3190 and 3300 nm (online and offline wavelengths) with a differential cross-section of 2.5 × 10−23 m2. Similarly, methane has been detected and quantified with concentration of 2.2 ppm up to 300 m using 3316 and 3326 nm (online and offline wavelengths, respectively).


  • Laser-Based Systems for Standoff Detection of CWA: A Short Review

    by Mukesh Kumar Jindal, Mainuddin Mainuddin, S. Veerabuthiran, Anil Kumar Razdan

    In recent times, the use of Chemical Warfare (CW) agents against civilian and military by terrorists and rogue countries are recurrent. The examples of such attacks are available in open literature. They are highly dangerous due to their acute toxicity nature. They tend to stimulate and paralyze nerve system of the body and cause other toxic side effects. Once these toxic chemicals are released into the atmosphere, timely detection and identification of the same at standoff distances will help the defensive forces to take proper counter measures. Detection techniques such as ion mobility spectrometry, infrared spectrometry, Raman spectrometry, FTIR, LIDAR etc. have been used widely. Among all these techniques, Raman spectroscopy techniques and LIDAR (LIght Detection and Ranging) is the only active remote detection method that can detect and discriminate the chemical agents at standoff distances. Infrared DIAL (Differential Absorption Lidar) is a versatile technique for remote detection of various chemicals. DIAL technique can provide spatially resolved measurements of these agents with sufficient sensitivity (at few ppm levels) at ranges of several kilometers by exploiting the concept such as scattering and absorption from the atmosphere. The main objective of this review paper is to bring out the details of highly potential chemical warfare agents, their properties and laser based remote detection sensors. LIDAR technique is emphasized in more detail because of their long range detection capability, sensitivity and selectivity. An overview of existing R&D based and commercial systems is also discussed.