Valérie M. Collas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Valérie M. Collas has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Inez E. Rodrigus
Antwerp University Hospital, Department of Cardiac Surgery, Wilrijkstraat 10, 2650 Edegem, Belgium
3 shared publicationsJohan M. Bosmans
University of Antwerp, Faculty of Medicine and Health Sciences, Department of Translational Pathophysiological Research, Cardiovascular diseases, Universiteitsplein 1, 2610 Antwerp, Belgium; Antwerp University Hospital, Department of Cardiology, Wilrijkstraat 10, 2650 Edegem, Belgium
3 shared publicationsBernard P. Paelinck
Antwerp University Hospital, Department of Cardiac Surgery, Wilrijkstraat 10, 2650 Edegem, Belgium
2 shared publicationsChristiaan J. Vrints
University of Antwerp, Faculty of Medicine and Health Sciences, Department of Translational Pathophysiological Research, Cardiovascular diseases, Universiteitsplein 1, 2610 Antwerp, Belgium; Antwerp University Hospital, Department of Cardiology, Wilrijkstraat 10, 2650 Edegem, Belgium
2 shared publicationsBernard De Bruyne
Department of Cardiology, OLV Ziekenhuis, Aalst, Belgium
1 shared publicationChristophe Dubois
Department of Cardiology and Cardiac Surgery, University Hospital Leuven, Leuven, Belgium
1 shared publication
Latest Publications
- 11 May 2015
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 86 (3) , 528-535
Midterm clinical outcome following Edwards SAPIEN or Medtronic Corevalve transcatheter aortic valve implantation (TAVI): Results of the Belgian TAVI registry
Objective: To assess midterm (3 years) clinical outcomes of transcatheter aortic valve implantation (TAVI) in Belgium using the Edwards SAPIEN valve or the Medtronic CoreValve transcatheter heart valve (THV).Background: Medium and long term follow‐up data of both THVs are still relatively scarce, although of great clinical relevance for a relatively new but rapidly expanding treatment modality. Therefore, reporting mid‐ and long term clinical outcome data, coming from large “real world” national registries, remains contributive.Methods: Between December 2007 and March 2012, 861 “real world” patients who were not candidates for surgical aortic valve replacement as decided by the local heart teams, underwent TAVI at 23 sites. Eleven sites exclusively used SAPIEN THV (n = 460), while 12 exclusively used CoreValve THV (n = 401). Differences in clinical outcomes by valve system were assessed, according to access route and baseline EuroSCORE risk profile (20%: high risk).Results: Overall cumulative survival at 3 years was 51% for SAPIEN vs. 60% for CoreValve (P = 0.021). In transfemorally treated patients, SAPIEN and CoreValve had similar survival at 3 years for each of the baseline EuroSCORE cohorts (low risk: 72% vs. 76%, P = 0.45; intermediate risk: 62% vs. 59%, P = 0.94; high risk: 48% vs. 53%, P = 0.65).Conclusion: Cumulative midterm 3 year survival after transfemoral TAVI in “real world” patients refused for surgery with similar baseline EuroSCORE risk profile is not different between SAPIEN or CoreValve.
- 11 May 2015
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 86 (3) , 528-535
Midterm clinical outcome following Edwards SAPIEN or Medtronic Corevalve transcatheter aortic valve implantation (TAVI): Results of the Belgian TAVI registry
Objective: To assess midterm (3 years) clinical outcomes of transcatheter aortic valve implantation (TAVI) in Belgium using the Edwards SAPIEN valve or the Medtronic CoreValve transcatheter heart valve (THV).Background: Medium and long term follow‐up data of both THVs are still relatively scarce, although of great clinical relevance for a relatively new but rapidly expanding treatment modality. Therefore, reporting mid‐ and long term clinical outcome data, coming from large “real world” national registries, remains contributive.Methods: Between December 2007 and March 2012, 861 “real world” patients who were not candidates for surgical aortic valve replacement as decided by the local heart teams, underwent TAVI at 23 sites. Eleven sites exclusively used SAPIEN THV (n = 460), while 12 exclusively used CoreValve THV (n = 401). Differences in clinical outcomes by valve system were assessed, according to access route and baseline EuroSCORE risk profile (20%: high risk).Results: Overall cumulative survival at 3 years was 51% for SAPIEN vs. 60% for CoreValve (P = 0.021). In transfemorally treated patients, SAPIEN and CoreValve had similar survival at 3 years for each of the baseline EuroSCORE cohorts (low risk: 72% vs. 76%, P = 0.45; intermediate risk: 62% vs. 59%, P = 0.94; high risk: 48% vs. 53%, P = 0.65).Conclusion: Cumulative midterm 3 year survival after transfemoral TAVI in “real world” patients refused for surgery with similar baseline EuroSCORE risk profile is not different between SAPIEN or CoreValve.
- 26 April 2015
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 49 (2) , 471-477
Red cell distribution width improves the prediction of prognosis after transcatheter aortic valve implantation
OBJECTIVES The aim of this study was to determine if red cell distribution width (RDW) could improve the prediction of prognosis after transcatheter aortic valve implantation (TAVI). METHODS In this single-centre study, 197 consecutive patients underwent TAVI (median age 82 (77-86), 46.2% men). Normal RDW at baseline was defined as ≤15.5%, elevated RDW at baseline was defined as >15.5%. Ouctomes according to the Valve Academic Research Consortium 2 and survival up to one year were compared between these groups. RESULTS Compared with the patients with RDW ≤15.5% (n = 168), those with RDW >15.5% (n = 29) had a higher Society of Thoracic Surgeon (STS) score (7.2 vs 5.0%, P = 0.041), higher systolic pulmonary arterial pressure (50 vs 41 mmHg, P = 0.021) and lower haemoglobin (11.5 vs 12.4 mg/dl, P = 0.003). Patients with RDW >15.5% developed significantly more adverse events after TAVI (major vascular complications: 10.3 vs 1.8%, P = 0.042; aortic regurgitation grade II–IV: 50.0 vs 18.0%, P = 0.001) and survival up to 1 year was significantly lower (85.6 vs 65.2%, log-rank: P = 0.007). In addition, RDW >15.5% at baseline was the most significant predictor for mortality (hazard ratio: 2.701 (1.279–5.704), P = 0.009), even when the STS score was added to the model [RDW >15.5%: hazard ratio: 2.276 (1.045–4.954), P = 0.038]. CONCLUSIONS Elevated RDW is a significant predictor for adverse events and increased 1-year mortality after TAVI. Adding RDW to the classical STS score could be a valuable strategy to improve preoperative risk assessment in potential TAVI candidates.
- 26 April 2015
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 49 (2) , 471-477
Red cell distribution width improves the prediction of prognosis after transcatheter aortic valve implantation
OBJECTIVES The aim of this study was to determine if red cell distribution width (RDW) could improve the prediction of prognosis after transcatheter aortic valve implantation (TAVI). METHODS In this single-centre study, 197 consecutive patients underwent TAVI (median age 82 (77-86), 46.2% men). Normal RDW at baseline was defined as ≤15.5%, elevated RDW at baseline was defined as >15.5%. Ouctomes according to the Valve Academic Research Consortium 2 and survival up to one year were compared between these groups. RESULTS Compared with the patients with RDW ≤15.5% (n = 168), those with RDW >15.5% (n = 29) had a higher Society of Thoracic Surgeon (STS) score (7.2 vs 5.0%, P = 0.041), higher systolic pulmonary arterial pressure (50 vs 41 mmHg, P = 0.021) and lower haemoglobin (11.5 vs 12.4 mg/dl, P = 0.003). Patients with RDW >15.5% developed significantly more adverse events after TAVI (major vascular complications: 10.3 vs 1.8%, P = 0.042; aortic regurgitation grade II–IV: 50.0 vs 18.0%, P = 0.001) and survival up to 1 year was significantly lower (85.6 vs 65.2%, log-rank: P = 0.007). In addition, RDW >15.5% at baseline was the most significant predictor for mortality (hazard ratio: 2.701 (1.279–5.704), P = 0.009), even when the STS score was added to the model [RDW >15.5%: hazard ratio: 2.276 (1.045–4.954), P = 0.038]. CONCLUSIONS Elevated RDW is a significant predictor for adverse events and increased 1-year mortality after TAVI. Adding RDW to the classical STS score could be a valuable strategy to improve preoperative risk assessment in potential TAVI candidates.