ACAllison L. Clouthier

Allison L. Clouthier

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Allison L. Clouthier has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The effect of articular geometry features identified using statistical shape modelling on knee biomechanics

    by Allison L. Clouthier, Colin R. Smith, Michael F. Vignos, Darryl G. Thelen, Kevin J. Deluzio, Michael J. Rainbow

    Articular geometry in the knee varies widely among people which has implications for risk of injury and pathology. The goals of this work were to develop a framework to systematically vary geometry in a multibody knee model and to use this framework to investigate the effect of morphological features on dynamic knee kinematics and contact mechanics. A statistical shape model of the tibiofemoral and patellofemoral joints was created from magnetic resonance images of 14 asymptomatic knees. The shape model was then used to generate 37 unique multibody knee models based on -3 to +3 standard deviations of the scores for the first six principal components identified. Each multibody model was then incorporated into a lower extremity musculoskeletal model and the Concurrent Optimization of Muscle Activations and Kinematics (COMAK) routine was used to simulate knee mechanics for overground walking. Changes in articular geometry affected knee function, resulting in differences up to 17° in orientation, 8 mm in translation, 0.7 BW in contact force, and 2.0 MPa in mean cartilage contact pressure. Understanding the relationship between shape and function in a joint could provide insight into the mechanisms behind injury and pathology and the variability in response to treatment.


  • Open Access

    Identification of good candidates for valgus bracing as a treatment for medial knee osteoarthritis

    by Allison L. Clouthier, Elizabeth A. Hassan, Scott C. E. Brandon, Aaron Campbell, Michael J. Rainbow, Kevin J. Deluzio

    Valgus unloader braces are a conservative treatment option for medial compartment knee osteoarthritis that aim to unload the damaged medial compartment through application of an external abduction moment. Patient response to bracing is highly variable, however. While some experience improvements in pain, function, and joint loading, others receive little to no benefit. The objective of this work was to analyze clinical measures and biomechanical characteristics of unbraced walking to identify variables that are associated with the mechanical effectiveness of valgus unloader bracing. Seventeen patients with medial knee osteoarthritis walked overground with and without a valgus unloader brace. A musculoskeletal model was used to estimate the contact forces in the medial compartment of the tibiofemoral joint and brace effectiveness was defined as the decrease in peak medial contact force between unbraced and braced conditions. Stepwise linear regression was used to identify clinical and biomechanical measures that predicted brace effectiveness. The final regression model explained 77% of the variance in brace effectiveness using two variables. Bracing was more effective for those with greater peak external hip adduction moments and for those with higher Kellgren–Lawrence grades, indicating more severe radiographic osteoarthritis. The hip adduction moment was the best predictor of brace effectiveness and was well correlated with several other measures indicating that it may be functioning as a “biomarker” for good bracing candidates. Clinical Significance: The ability to predict good candidates for valgus bracing may improve issues of patient compliance and could enable the ability to train patients to respond better to bracing. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:351–356, 2018.


  • Correcting waveform bias using principal component analysis: Applications in multicentre motion analysis studies

    by Allison L. Clouthier, Eric R. Bohm, John F. Rudan, Barbara L. Shay, Michael J. Rainbow, Kevin J. Deluzio


  • Finite element analysis predicts experimental failure patterns in vertebral bodies loaded via intervertebral discs up to large deformation

    by Allison L. Clouthier, Hadi S. Hosseini, Ghislain Maquer, Philippe K. Zysset

    Vertebral compression fractures are becoming increasingly common. Patient-specific nonlinear finite element (FE) models have shown promise in predicting yield strength and damage pattern but have not been experimentally validated for clinically relevant vertebral fractures, which involve loading through intervertebral discs with varying degrees of degeneration up to large compressive strains. Therefore, stepwise axial compression was applied in vitro on segments and performed in silico on their FE equivalents using a nonlocal damage-plastic model including densification at large compression for bone and a time-independent hyperelastic model for the disc. The ability of the nonlinear FE models to predict the failure pattern in large compression was evaluated for three boundary conditions: healthy and degenerated intervertebral discs and embedded endplates. Bone compaction and fracture patterns were predicted using the local volume change as an indicator and the best correspondence was obtained for the healthy intervertebral discs. These preliminary results show that nonlinear finite element models enable prediction of bone localisation and compaction. To the best of our knowledge, this is the first study to predict the collapse of osteoporotic vertebral bodies up to large compression using realistic loading via the intervertebral discs.