Hans-Joachim Stärk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hans-Joachim Stärk has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Jörg Rinklebe
School of Architecture and Civil Engineering, Institute of Foundation Engineering, Water- and Waste-Management, Laboratory of Soil- and Groundwater-Management, University of Wuppertal, Wuppertal, Germany
2 shared publications - Andreas Koelsch
Helmholtz Centre for Environmental Research GmbH—UFZ, Department Environmental Microbiology, Permoserstrasse 15, Leipzig 04318, Germany
1 shared publication - Cecilia Panigatti
Facultad Regional Rafaela, Universidad Tecnologica Nacional, M. Acuña 49, Rafaela 2300, Argentina
1 shared publication - Dubravka Savić
University of Belgrade-Faculty of Agriculture, Nemanjina 6, 11 080, Belgrade, Serbia
1 shared publication - Eva Osterwalder
Helmholtz Centre for Environmental Research GmbH—UFZ, Department Environmental Microbiology, Permoserstrasse 15, Leipzig 04318, Germany
1 shared publication - Fernando D. Reina
Facultad Regional Buenos Aires, Universidad Tecnologica Nacional, Medrano 951, Argentina
1 shared publication
Latest Publications
- 1 August 2017
- Published by Elsevier in Chemosphere
- Vol. 181, 313-319
Rare earth elements and their release dynamics under pre-definite redox conditions in a floodplain soil
- 1 August 2017
- Published by Elsevier in Chemosphere
- Vol. 181, 313-319
Rare earth elements and their release dynamics under pre-definite redox conditions in a floodplain soil
- 1 July 2017
- Published by Elsevier in Chemosphere
- Vol. 178, 268-276
Redox-controlled release dynamics of thallium in periodically flooded arable soil
- 1 July 2017
- Published by Elsevier in Chemosphere
- Vol. 178, 268-276
Redox-controlled release dynamics of thallium in periodically flooded arable soil
- Open Access
- 21 May 2015
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 12 (5) , 5465-5482
Introducing Simple Detection of Bioavailable Arsenic at Rafaela (Santa Fe Province, Argentina) Using the ARSOlux Biosensor
Numerous articles have reported the occurrence of arsenic in drinking water in Argentina, and the resulting health effects in severely affected regions of the country. Arsenic in drinking water in Argentina is largely naturally occurring due to elevated background content of the metalloid in volcanic sediments, although, in some regions, mining can contribute. While the origin of arsenic release has been discussed extensively, the problem of drinking water contamination has not yet been solved. One key step in progress towards mitigation of problems related with the consumption of As-containing water is the availability of simple detection tools. A chemical test kit and the ARSOlux biosensor were evaluated as simple analytical tools for field measurements of arsenic in the groundwater of Rafaela (Santa Fe, Argentina), and the results were compared with ICP-MS and HPLC-ICP-MS measurements. A survey of the groundwater chemistry was performed to evaluate possible interferences with the field tests. The results showed that the ARSOlux biosensor performed better than the chemical field test, that the predominant species of arsenic in the study area was arsenate and that arsenic concentration in the studied samples had a positive correlation with fluoride and vanadium, and a negative one with calcium and iron.
- 21 May 2015
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 12 (5) , 5465-5482
Open AccessIntroducing Simple Detection of Bioavailable Arsenic at Rafaela (Santa Fe Province, Argentina) Using the ARSOlux Biosensor
Numerous articles have reported the occurrence of arsenic in drinking water in Argentina, and the resulting health effects in severely affected regions of the country. Arsenic in drinking water in Argentina is largely naturally occurring due to elevated background content of the metalloid in volcanic sediments, although, in some regions, mining can contribute. While the origin of arsenic release has been discussed extensively, the problem of drinking water contamination has not yet been solved. One key step in progress towards mitigation of problems related with the consumption of As-containing water is the availability of simple detection tools. A chemical test kit and the ARSOlux biosensor were evaluated as simple analytical tools for field measurements of arsenic in the groundwater of Rafaela (Santa Fe, Argentina), and the results were compared with ICP-MS and HPLC-ICP-MS measurements. A survey of the groundwater chemistry was performed to evaluate possible interferences with the field tests. The results showed that the ARSOlux biosensor performed better than the chemical field test, that the predominant species of arsenic in the study area was arsenate and that arsenic concentration in the studied samples had a positive correlation with fluoride and vanadium, and a negative one with calcium and iron.
- 24 November 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 399 (6) , 2211-2217
A new approach for calibration of laser ablation inductively coupled plasma mass spectrometry using thin layers of spiked agarose gels as references
Calibration of analytical methods using laser ablation for sample introduction is often problematic. The availability of matrix-adapted standard materials is a crucial factor in the analysis of biological samples in particular. In this work a method for preparation of thin-film references for LA–ICP–MS is presented which is inexpensive, relatively simple and generally practicable. Aqueous solutions of agarose spiked with defined amounts of the analytes were cast on a carrier and then dried. When the thin-film references were characterized the average thickness of the films was 0.03 mm in the centre of the film and the relative standard deviation was 8%. Nebulization ICP–MS analysis after acid digestion of the agarose film was used to investigate the effectiveness of the spiking procedure. Recovery of the spiked elements was frequently in the range 90–110% (for rare earth elements 97–102%). Laser ablation ICP–MS analysis was used to investigate the distribution of the spiked elements in the film. When the laser was scanned across the gel the measured intensities were not constant, but had a peak-shaped profile with a flat top. Use of this flat-top region for analytical purposes, after its characterization by laser ablation ICP–MS, is proposed. Analysis of cell cultures was carried out by direct laser ablation-ICP–MS with the calibration method described. The results were in accordance with values previously achieved by nebulization ICP–MS.
- 24 November 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 399 (6) , 2211-2217
A new approach for calibration of laser ablation inductively coupled plasma mass spectrometry using thin layers of spiked agarose gels as references
Calibration of analytical methods using laser ablation for sample introduction is often problematic. The availability of matrix-adapted standard materials is a crucial factor in the analysis of biological samples in particular. In this work a method for preparation of thin-film references for LA–ICP–MS is presented which is inexpensive, relatively simple and generally practicable. Aqueous solutions of agarose spiked with defined amounts of the analytes were cast on a carrier and then dried. When the thin-film references were characterized the average thickness of the films was 0.03 mm in the centre of the film and the relative standard deviation was 8%. Nebulization ICP–MS analysis after acid digestion of the agarose film was used to investigate the effectiveness of the spiking procedure. Recovery of the spiked elements was frequently in the range 90–110% (for rare earth elements 97–102%). Laser ablation ICP–MS analysis was used to investigate the distribution of the spiked elements in the film. When the laser was scanned across the gel the measured intensities were not constant, but had a peak-shaped profile with a flat top. Use of this flat-top region for analytical purposes, after its characterization by laser ablation ICP–MS, is proposed. Analysis of cell cultures was carried out by direct laser ablation-ICP–MS with the calibration method described. The results were in accordance with values previously achieved by nebulization ICP–MS.