Anwar Ali Sahito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anwar Ali Sahito has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Irfan Ahmed Halepoto
3 shared publications- Abdul Hameed Soomro
Quai-e-Awam University Nawabshah Campus Larkano
1 shared publication Abdul Sattar Larik
Mehran University of Engineering and Technology
1 shared publication- Abdul Sattar Larik
MUET Jamshoro
1 shared publication Bhawani Shankar Chowdhry
1 shared publicationMansoor Ahmed Soomro
1 shared publication
Latest Publications
- Open Access
- 7 November 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (21) , 14661
Simulation-Based Comparison of PID with Sliding Mode Controller for Matrix-Converter-Based Dynamic Voltage Restorer under Variation of System Parameters to Alleviate the Voltage Sag in Distribution System
A constant power supply is a basic need for each consumer due to the increase in sensitive equipment day by day. As per IEEE standards, a 10% reduction in voltage from the supply voltage is not acceptable and may cause the failure of equipment. Previously, different techniques have been used to alleviate the voltage sag, such as STATCOM, DSTATCOM, SVC, and shunt capacitors, but these devices are connected in parallel, which compensates for the low value of voltage sag, and they have high maintenance costs involved. Compensation for the low and high values of voltage sag is possible through a series-connected device such as a dynamic voltage restorer. In this paper, a matrix converter is presented for DVR to convert AC to AC voltage directly and free from batteries, capacitors, and multiple conversions as needed in a voltage source inverter, resulting in a reduced cost of DVR topology. The DVR is meaningless in the absence of a controller, so it is necessary to select a suitable controller for the satisfactory operation of the DVR under a variation of system parameters. In this paper, the performance of a linear PID controller is analyzed and compared with a nonlinear controller, such as a sliding-mode controller, under variation of power system parameters inorder to select a robust controller that performs satisfactorily for DVR. Earlier trial-and-error methods were used to obtain the parameters of PID gains, but they require a large time to obtain the parameters of the PID gains and there is a chance of inaccuracy. A genetic algorithm was used to obtain the gain parameters, but it has more convergence time and the particle swarm optimization technique has involves less reliability. In this research paper, the sliding surface coefficient parameters such as and Ki for the PI sliding surface of SMC and PID gains are taken through an ant colony algorithm to obtain the robustness of the controllers. The purpose of this paper is to introduce the best DVR topology with reduced cost. MATLAB simulation software was utilized to analyze the performance of the DVR with PID and SMC controllers under different fault conditions and also the THD% of proposed controllers was analyzed through FFT.
- 7 November 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (21) , 14661
Open AccessSimulation-Based Comparison of PID with Sliding Mode Controller for Matrix-Converter-Based Dynamic Voltage Restorer under Variation of System Parameters to Alleviate the Voltage Sag in Distribution System
A constant power supply is a basic need for each consumer due to the increase in sensitive equipment day by day. As per IEEE standards, a 10% reduction in voltage from the supply voltage is not acceptable and may cause the failure of equipment. Previously, different techniques have been used to alleviate the voltage sag, such as STATCOM, DSTATCOM, SVC, and shunt capacitors, but these devices are connected in parallel, which compensates for the low value of voltage sag, and they have high maintenance costs involved. Compensation for the low and high values of voltage sag is possible through a series-connected device such as a dynamic voltage restorer. In this paper, a matrix converter is presented for DVR to convert AC to AC voltage directly and free from batteries, capacitors, and multiple conversions as needed in a voltage source inverter, resulting in a reduced cost of DVR topology. The DVR is meaningless in the absence of a controller, so it is necessary to select a suitable controller for the satisfactory operation of the DVR under a variation of system parameters. In this paper, the performance of a linear PID controller is analyzed and compared with a nonlinear controller, such as a sliding-mode controller, under variation of power system parameters inorder to select a robust controller that performs satisfactorily for DVR. Earlier trial-and-error methods were used to obtain the parameters of PID gains, but they require a large time to obtain the parameters of the PID gains and there is a chance of inaccuracy. A genetic algorithm was used to obtain the gain parameters, but it has more convergence time and the particle swarm optimization technique has involves less reliability. In this research paper, the sliding surface coefficient parameters such as and Ki for the PI sliding surface of SMC and PID gains are taken through an ant colony algorithm to obtain the robustness of the controllers. The purpose of this paper is to introduce the best DVR topology with reduced cost. MATLAB simulation software was utilized to analyze the performance of the DVR with PID and SMC controllers under different fault conditions and also the THD% of proposed controllers was analyzed through FFT.
- 29 December 2016
- Published by Indian Society for Education and Environment in Indian Journal of Science and Technology
- Vol. 9 (47)
Design and Modeling of Substation Time Critical Information Dissemination Model using Publishersubscriber Communication Service Mapping
Objectives: For the efficient and reliable operation, substation IEDs status must be monitored consistently and event information must be disseminated timely between substation levels. Methods/Statistical Analysis: Traditional power grid substations are facing infrastructural, operational, automation, systematic, monitoring and control issues. The smart grid concept and advancement in instrumentation and automation has open up the potential of substation automation system through which substation automation, intelligence and control is achieved, but devices interfacing, interoperability, time critical information exchange, substation devices status monitoring and data dissemination type issues are still in research phase. Findings: In this research work, substation bay level IEDs time critical data information dissemination model is designed by IEC 61850 standard using publisher subscriber communication. Based on IEC 61850 substation devices data object and interfacing models, a novel substation communication service mapping is proposed for the time critical data information dissemination. The proposed communication service mapping is based on abstract service communication interface technique by which an object oriented data and object models and communication service is directly mapped at Ethernet data link layer. Application/Improvements: To disseminate the data message using the proposed communication service an IEEE 802 based Ethernet frame structure is designed and configured using abstract syntax notation one technique.
- 29 December 2016
- Published by Indian Society for Education and Environment in Indian Journal of Science and Technology
- Vol. 9 (47)
Design and Modeling of Substation Time Critical Information Dissemination Model using Publishersubscriber Communication Service Mapping
Objectives: For the efficient and reliable operation, substation IEDs status must be monitored consistently and event information must be disseminated timely between substation levels. Methods/Statistical Analysis: Traditional power grid substations are facing infrastructural, operational, automation, systematic, monitoring and control issues. The smart grid concept and advancement in instrumentation and automation has open up the potential of substation automation system through which substation automation, intelligence and control is achieved, but devices interfacing, interoperability, time critical information exchange, substation devices status monitoring and data dissemination type issues are still in research phase. Findings: In this research work, substation bay level IEDs time critical data information dissemination model is designed by IEC 61850 standard using publisher subscriber communication. Based on IEC 61850 substation devices data object and interfacing models, a novel substation communication service mapping is proposed for the time critical data information dissemination. The proposed communication service mapping is based on abstract service communication interface technique by which an object oriented data and object models and communication service is directly mapped at Ethernet data link layer. Application/Improvements: To disseminate the data message using the proposed communication service an IEEE 802 based Ethernet frame structure is designed and configured using abstract syntax notation one technique.
- 28 December 2016
- Published by Indian Society for Education and Environment in Indian Journal of Science and Technology
- Vol. 9 (47)
Analyzing the Impacts of Wind Generation on Distribution System Performance
Increasing wind power generation affects performance of existing power system in terms of power losses, voltage regulation and short circuit levels. Jhimpir wind generation having 49.5 MW capacity is connected to 132kV network of Hyderabd Electric Supply Company (HESCO) to meet its energy demand. Distribution network of HESCO is modelled and simulated using Power system Simulator – Siemens Network Calculator (PSS SINCAL) as simulation platform. Simulation results are compared to observe impacts of wind integration to existing power system network. Simulation results indicate reduction of power losses from 15.26 to 14.79MW as a result of wind integration to existing HESCO network. Reduction in power losses is mainly caused by changed current flows in lines. Reduction in current also reduce line drops resulting in improved bus voltages. Short circuit level is slightly increased for all buses due to network modification. Increase in short circuit level is highest near the wind generation as Zorlu grid shows 13.02% increase. 66kV network shows small increase in short circuit level due to its long distance from wind generation facility. Use of real network data for this research work identifies possible protection issues alongwith the reduction in power losses and voltage drop. Each system network has separate network parameters and will have different response to any network change. Hence a simulation analysis is important to ensure maximum benefits from renewable energy sources and their integration with existing power system network
- 28 December 2016
- Published by Indian Society for Education and Environment in Indian Journal of Science and Technology
- Vol. 9 (47)
Analyzing the Impacts of Wind Generation on Distribution System Performance
Increasing wind power generation affects performance of existing power system in terms of power losses, voltage regulation and short circuit levels. Jhimpir wind generation having 49.5 MW capacity is connected to 132kV network of Hyderabd Electric Supply Company (HESCO) to meet its energy demand. Distribution network of HESCO is modelled and simulated using Power system Simulator – Siemens Network Calculator (PSS SINCAL) as simulation platform. Simulation results are compared to observe impacts of wind integration to existing power system network. Simulation results indicate reduction of power losses from 15.26 to 14.79MW as a result of wind integration to existing HESCO network. Reduction in power losses is mainly caused by changed current flows in lines. Reduction in current also reduce line drops resulting in improved bus voltages. Short circuit level is slightly increased for all buses due to network modification. Increase in short circuit level is highest near the wind generation as Zorlu grid shows 13.02% increase. 66kV network shows small increase in short circuit level due to its long distance from wind generation facility. Use of real network data for this research work identifies possible protection issues alongwith the reduction in power losses and voltage drop. Each system network has separate network parameters and will have different response to any network change. Hence a simulation analysis is important to ensure maximum benefits from renewable energy sources and their integration with existing power system network
- 16 May 2015
- Published by Springer Nature in Wireless Personal Communications
- Vol. 85 (2) , 545-563
Analyzing the Impacts of Distributed Generation Integration on Distribution Network: A Corridor Towards Smart Grid Implementation in Pakistan
- 16 May 2015
- Published by Springer Nature in Wireless Personal Communications
- Vol. 85 (2) , 545-563
Analyzing the Impacts of Distributed Generation Integration on Distribution Network: A Corridor Towards Smart Grid Implementation in Pakistan