Timothy J. Fendler
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Timothy J. Fendler has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- John A. Spertus
University of Missouri – Kansas City Healthcare Institute for Innovations in Quality and Saint Luke’s Mid America Heart Institute (J.A.S.).
4 shared publications - Kevin F. Kennedy
Saint Luke's Mid America Heart Institute, Kansas City, MO, United States
3 shared publications - Larry A. Allen
Division of Cardiology, Department of Medicine, University of Colorado, Aurora (L.A.A.).
2 shared publications Michael E. Nassif
From the Mid-America Heart Institute, Kansas City, MO (T.J.F., J.A.S., K.L.G., P.G.J., S.V.A.); University of Missouri-Kansas City (T.J.F., J.A.S., J.M.B., S.V.A.); Washington University School of Medicine, Saint Louis, MO (M.E.N.); University of Colorado School of Medicine, Aurora (K.M.F., L.A.A.); and Mayo Clinic of Rochester, MN (S.M.D.).
2 shared publications- Paul S. Chan
University of Missouri-Kansas City
2 shared publications - Shane J. LaRue
Division of Cardiology, Washington University School of Medicine, St. Louis, Missouri
2 shared publications
Latest Publications
- 1 November 2017
- Published by Elsevier in American Heart Journal
- Vol. 193, 108-116
Association between hospital rates of early Do-Not-Resuscitate orders and favorable neurological survival among survivors of inhospital cardiac arrest
- 1 November 2017
- Published by Elsevier in American Heart Journal
- Vol. 193, 108-116
Association between hospital rates of early Do-Not-Resuscitate orders and favorable neurological survival among survivors of inhospital cardiac arrest
- 1 April 2017
- Published by Elsevier in The American Journal of Cardiology
- Vol. 119 (7) , 1069-1073
Global Outcome in Patients With Left Ventricular Assist Devices
- 1 April 2017
- Published by Elsevier in The American Journal of Cardiology
- Vol. 119 (7) , 1069-1073
Global Outcome in Patients With Left Ventricular Assist Devices
- Open Access
- 14 March 2017
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 17 (1) , 78
Association of global and disease-specific health status with outcomes following continuous-flow left ventricular assist device implantation
The prognostic value of heart failure specific and global health status before and after left ventricular assist device (LVAD) implantation in the usual care setting is not well studied. We included 3,836 continuous-flow LVAD patients in the INTERMACS registry. Health status was measured pre-operatively and 3 months post-LVAD using the Kansas City Cardiomyopathy Questionnaire (KCCQ) and EuroQol visual analog scale (VAS). Primary outcomes were mortality/rehospitalization. Inverse propensity weighting was used to minimize bias from missing data. Pre-operative global and heart failure-specific health status were very poor: KCCQ median 34.6 (IQR 21.4-50.5); VAS median 43 (interquartile range (IQR) 25–65). Health status measures improved 3 months after LVAD placement: KCCQ median 69.3 (IQR 54.2-82.3); VAS median 75 (IQR 60–85). Pre-operative health status was not associated with death (unadjusted HR for lowest vs. highest score quartiles: 1.09 (0.85-1.41) KCCQ; 1.12 (0.85-1.49) VAS) or rehospitalization (unadjusted HR 0.83 (0.72-0.96) KCCQ; 0.99 (0.85-1.16) VAS). Three-month KCCQ was associated with mortality (unadjusted HR 2.17 (1.47-3.21); VAS was not (1.43 (0.94-2.17). Three-month KCCQ added incremental discriminatory value to the HeartMate II Risk Score for death (c-stat 0.60 to 0.66); VAS did not (c-stat 0.59 to 0.60). Three-month health status was associated with rehospitalization (unadjusted HR 1.31 (1.15-1.57) KCCQ; 1.24 (1.05-1.46) VAS), but did not add incremental discriminatory value (c-stat 0.52 to 0.55 and 0.54, respectively). These real-world data suggest that pre-operative health status has limited association with outcomes after LVAD. However, persistently low health status after surgery may independently signal higher risk for subsequent death. Further study is needed to determine the clinical utility of routinely collected health status data after LVAD implantation.
- 14 March 2017
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 17 (1) , 78
Open AccessAssociation of global and disease-specific health status with outcomes following continuous-flow left ventricular assist device implantation
The prognostic value of heart failure specific and global health status before and after left ventricular assist device (LVAD) implantation in the usual care setting is not well studied. We included 3,836 continuous-flow LVAD patients in the INTERMACS registry. Health status was measured pre-operatively and 3 months post-LVAD using the Kansas City Cardiomyopathy Questionnaire (KCCQ) and EuroQol visual analog scale (VAS). Primary outcomes were mortality/rehospitalization. Inverse propensity weighting was used to minimize bias from missing data. Pre-operative global and heart failure-specific health status were very poor: KCCQ median 34.6 (IQR 21.4-50.5); VAS median 43 (interquartile range (IQR) 25–65). Health status measures improved 3 months after LVAD placement: KCCQ median 69.3 (IQR 54.2-82.3); VAS median 75 (IQR 60–85). Pre-operative health status was not associated with death (unadjusted HR for lowest vs. highest score quartiles: 1.09 (0.85-1.41) KCCQ; 1.12 (0.85-1.49) VAS) or rehospitalization (unadjusted HR 0.83 (0.72-0.96) KCCQ; 0.99 (0.85-1.16) VAS). Three-month KCCQ was associated with mortality (unadjusted HR 2.17 (1.47-3.21); VAS was not (1.43 (0.94-2.17). Three-month KCCQ added incremental discriminatory value to the HeartMate II Risk Score for death (c-stat 0.60 to 0.66); VAS did not (c-stat 0.59 to 0.60). Three-month health status was associated with rehospitalization (unadjusted HR 1.31 (1.15-1.57) KCCQ; 1.24 (1.05-1.46) VAS), but did not add incremental discriminatory value (c-stat 0.52 to 0.55 and 0.54, respectively). These real-world data suggest that pre-operative health status has limited association with outcomes after LVAD. However, persistently low health status after surgery may independently signal higher risk for subsequent death. Further study is needed to determine the clinical utility of routinely collected health status data after LVAD implantation.
- Open Access
- 22 September 2015
- Published by American Medical Association (AMA) in JAMA
- Vol. 314 (12) , 1264-1271
Alignment of Do-Not-Resuscitate Status With Patients’ Likelihood of Favorable Neurological Survival After In-Hospital Cardiac Arrest
Quiz Ref ID Do-not-resuscitate (DNR) orders are often established for patients whose prognosis is poor. One such example is in-hospital cardiac arrest, which affects nearly 200 000 patients in the United States annually, with rates of favorable neurological survival (ie, survival without severe cognitive disability) of less than 20%.1 Accordingly, this poor prognosis frequently prompts discussions about DNR status among resuscitated patients and their families.2 However, the likelihood of favorable neurological survival is variably influenced by many factors, including patients’ age, illness severity, comorbidities, and arrest characteristics.3-7 It therefore remains unknown if real-world decisions for DNR orders after successful resuscitation from in-hospital cardiac arrest are aligned with patients’ likelihood of favorable neurological survival.
- 22 September 2015
- Published by American Medical Association (AMA) in JAMA
- Vol. 314 (12) , 1264-1271
Open AccessAlignment of Do-Not-Resuscitate Status With Patients’ Likelihood of Favorable Neurological Survival After In-Hospital Cardiac Arrest
Quiz Ref ID Do-not-resuscitate (DNR) orders are often established for patients whose prognosis is poor. One such example is in-hospital cardiac arrest, which affects nearly 200 000 patients in the United States annually, with rates of favorable neurological survival (ie, survival without severe cognitive disability) of less than 20%.1 Accordingly, this poor prognosis frequently prompts discussions about DNR status among resuscitated patients and their families.2 However, the likelihood of favorable neurological survival is variably influenced by many factors, including patients’ age, illness severity, comorbidities, and arrest characteristics.3-7 It therefore remains unknown if real-world decisions for DNR orders after successful resuscitation from in-hospital cardiac arrest are aligned with patients’ likelihood of favorable neurological survival.
- 1 July 2015
- Published by Elsevier in Heart Failure Clinics
- Vol. 11 (3) , 479-498
Team-based Palliative and End-of-life Care for Heart Failure
- 1 July 2015
- Published by Elsevier in Heart Failure Clinics
- Vol. 11 (3) , 479-498
Team-based Palliative and End-of-life Care for Heart Failure
- 1 May 2015
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Quality and Outcomes
- Vol. 8 (3) , 285-291
Incidence and Predictors of Cognitive Decline in Patients with Left Ventricular Assist Devices
Background—: After left ventricular assist device (LVAD) placement for advanced heart failure, increased cerebral perfusion should result in improved cognitive function. However, stroke (a well-known LVAD complication) and subclinical cerebral ischemia may result in transient or permanent cognitive decline. We sought to describe the incidence and predictors of cognitive decline after LVAD using a valid, sensitive assessment tool. Methods and Results—: Among 4419 patients in the Interagency Registry for Mechanically Assisted Circulatory Support who underwent LVAD implantation between May 2012 and December 2013, cognitive function was assessed in 1173 patients with the Trail Making B Test before LVAD and at 3, 6, and 12 months. The test detects several forms of cognitive impairment, including subclinical stroke. Cognitive decline was defined as a clinically important increase during follow-up using a moderate Cohen d effect size of 0.5×baseline SD (32 s). The cumulative incidence of cognitive decline in the year after LVAD implantation, treating death and transplantation as competing risks, was 29.2%. In adjusted analysis, older age (≥70 versus P trend <0.001) and destination therapy (hazard ratio, 1.42; 95% confidence interval, 1.05–1.92) were significantly associated with greater risk of cognitive decline. Conclusions—: Cognitive decline occurs commonly in patients in the year after LVAD and is associated with older age and destination therapy. These results could have important implications for patient selection and improved communication of risks before LVAD implantation. Additional studies are needed to explore the association between cognitive decline and subsequent stroke, health status, and mortality in patients after LVAD.
- 1 May 2015
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Quality and Outcomes
- Vol. 8 (3) , 285-291
Incidence and Predictors of Cognitive Decline in Patients with Left Ventricular Assist Devices
Background—: After left ventricular assist device (LVAD) placement for advanced heart failure, increased cerebral perfusion should result in improved cognitive function. However, stroke (a well-known LVAD complication) and subclinical cerebral ischemia may result in transient or permanent cognitive decline. We sought to describe the incidence and predictors of cognitive decline after LVAD using a valid, sensitive assessment tool. Methods and Results—: Among 4419 patients in the Interagency Registry for Mechanically Assisted Circulatory Support who underwent LVAD implantation between May 2012 and December 2013, cognitive function was assessed in 1173 patients with the Trail Making B Test before LVAD and at 3, 6, and 12 months. The test detects several forms of cognitive impairment, including subclinical stroke. Cognitive decline was defined as a clinically important increase during follow-up using a moderate Cohen d effect size of 0.5×baseline SD (32 s). The cumulative incidence of cognitive decline in the year after LVAD implantation, treating death and transplantation as competing risks, was 29.2%. In adjusted analysis, older age (≥70 versus P trend <0.001) and destination therapy (hazard ratio, 1.42; 95% confidence interval, 1.05–1.92) were significantly associated with greater risk of cognitive decline. Conclusions—: Cognitive decline occurs commonly in patients in the year after LVAD and is associated with older age and destination therapy. These results could have important implications for patient selection and improved communication of risks before LVAD implantation. Additional studies are needed to explore the association between cognitive decline and subsequent stroke, health status, and mortality in patients after LVAD.
- 31 August 2013
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 19 (8) , S60
Poor Glycemic Control Is Associated with Worse Outcomes in Patients with Type II Diabetes Who Undergo Left Ventricular Assist Device Implantation
- 31 August 2013
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 19 (8) , S60
Poor Glycemic Control Is Associated with Worse Outcomes in Patients with Type II Diabetes Who Undergo Left Ventricular Assist Device Implantation