Sangyoup Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sangyoup Lee has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
Jong-Chul Lee
School of Mechanical and Automotive Engineering, Gangneung-Wonju National University, Wonju 26403, Republic of Korea
5 shared publications- Kihwan Nam
Center for Bionics, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Hwarangno 14-gil 5, Seongbuk-gu, Seoul 02792, Korea
2 shared publications Se-Hee Lee
Department of Electrical Engineering, Kyungpook National University, Daegu 41566, Republic of Korea
2 shared publicationsWon-Ho Lee
Graduate School of Automotive Engineering, Gangneung-Wonju National University, Wonju 26403, Republic of Korea
2 shared publications- Changje Lee
Research Institute of Maritime Industry, Korea Maritime and Ocean University, Busan, Korea
1 shared publication - Dae Sung Yoon
School of Biomedical Engineering Korea University Seoul 02841 Republic of Korea
1 shared publication
Latest Publications
- 19 March 2024
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 16 (17) , 8352-8360
Exploring single-molecule interactions: heparin and FGF-1 proteins through solid-state nanopores
We present a successful discrimination of heparin, FGF-1, and heparin–FGF-1 complexes at a single-molecule level through solid-state nanopores.
- 19 March 2024
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 16 (17) , 8352-8360
Exploring single-molecule interactions: heparin and FGF-1 proteins through solid-state nanopores
We present a successful discrimination of heparin, FGF-1, and heparin–FGF-1 complexes at a single-molecule level through solid-state nanopores.
- 30 October 2020
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 17 (1) , 136-144
Clogged water bridges for fog harvesting
Capillary water bridges clogged in the holes of mesh-type fog harvesters have previously been considered only as a drawback because they decrease fog-harvesting yield by hindering airflow in front of the clogged mesh in the usual wind conditions. In this study, we show that the role of a clogged water bridge may not be entirely negative and can contribute to increased fog harvesting by increasing the effective shade coefficient in a special condition with high fog inertia. As the fog speed close to the mesh or the plate increases, clogged mesh as well as the impermeable solid plate are found to produce high fog-harvesting efficiency owing to the high inertia of fog particles that impact the blocked wall. For fast fog speeds (∼4 m s−1) near the mesh, our results show that the fog-harvesting efficiency is proportional to the effective shade coefficient because fog flow circumventing the mesh is limited owing to high fog inertia. We analyzed the clogging effect on fog-harvesting performance by distinguishing between self-clogging and non-self-clogging patterns based on the water bridge stability clogged in mesh holes.
- 30 October 2020
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 17 (1) , 136-144
Clogged water bridges for fog harvesting
Capillary water bridges clogged in the holes of mesh-type fog harvesters have previously been considered only as a drawback because they decrease fog-harvesting yield by hindering airflow in front of the clogged mesh in the usual wind conditions. In this study, we show that the role of a clogged water bridge may not be entirely negative and can contribute to increased fog harvesting by increasing the effective shade coefficient in a special condition with high fog inertia. As the fog speed close to the mesh or the plate increases, clogged mesh as well as the impermeable solid plate are found to produce high fog-harvesting efficiency owing to the high inertia of fog particles that impact the blocked wall. For fast fog speeds (∼4 m s−1) near the mesh, our results show that the fog-harvesting efficiency is proportional to the effective shade coefficient because fog flow circumventing the mesh is limited owing to high fog inertia. We analyzed the clogging effect on fog-harvesting performance by distinguishing between self-clogging and non-self-clogging patterns based on the water bridge stability clogged in mesh holes.
- Open Access
- 5 February 2020
- Published by MDPI AG in Electronics
- Vol. 9 (2) , 269
Wireless Epidermal Electromyogram Sensing System
Massive efforts to build walking aid platforms for the disabled have been made in line with the needs of the aging society. One of the core technologies that make up these platforms is a realization of the skin-like electronic patch, which is capable of sensing electromyogram (EMG) and delivering feedback information to the soft, lightweight, and wearable exosuits, while maintaining high signal-to-noise ratio reliably in the long term. The main limitations of the conventional EMG sensing platforms include the need to apply foam tape or conductive gel on the surface of the device for adhesion and signal acquisition, and also the bulky size and weight of conventional measuring instruments for EMG, limiting practical use in daily life. Herein, we developed an epidermal EMG electrode integrated with a wireless measuring system. Such the stretchable platform was realized by transfer-printing of the as-prepared EMG electrodes on a SiO2 wafer to a polydimethylsiloxane (PDMS) elastomer substrate. The epidermal EMG patch has skin-like properties owing to its unique mechanical characteristics: i) location on a neutral mechanical plane that enables high flexibility, ii) wavy design that allows for high stretchability. We demonstrated wireless EMG monitoring using our skin-attachable and stretchable EMG patch sensor integrated with the miniaturized wireless system modules.
- 5 February 2020
- Published by MDPI AG in Electronics
- Vol. 9 (2) , 269
Open AccessWireless Epidermal Electromyogram Sensing System
Massive efforts to build walking aid platforms for the disabled have been made in line with the needs of the aging society. One of the core technologies that make up these platforms is a realization of the skin-like electronic patch, which is capable of sensing electromyogram (EMG) and delivering feedback information to the soft, lightweight, and wearable exosuits, while maintaining high signal-to-noise ratio reliably in the long term. The main limitations of the conventional EMG sensing platforms include the need to apply foam tape or conductive gel on the surface of the device for adhesion and signal acquisition, and also the bulky size and weight of conventional measuring instruments for EMG, limiting practical use in daily life. Herein, we developed an epidermal EMG electrode integrated with a wireless measuring system. Such the stretchable platform was realized by transfer-printing of the as-prepared EMG electrodes on a SiO2 wafer to a polydimethylsiloxane (PDMS) elastomer substrate. The epidermal EMG patch has skin-like properties owing to its unique mechanical characteristics: i) location on a neutral mechanical plane that enables high flexibility, ii) wavy design that allows for high stretchability. We demonstrated wireless EMG monitoring using our skin-attachable and stretchable EMG patch sensor integrated with the miniaturized wireless system modules.
- Open Access
Shaping Rolling Circle Amplification Products into DNA Nanoparticles by Incorporation of Modified Nucleotides and Their Application to In Vitro and In Vivo Delivery of a Photosensitizer
Rolling circle amplification (RCA) is a robust way to generate DNA constructs, which are promising materials for biomedical applications including drug delivery because of their high biocompatibility. To be employed as a drug delivery platform, however, the DNA materials produced by RCA need to be shaped into nanoparticles that display both high cellular uptake efficiency and nuclease resistance. Here, we showed that the DNA nanoparticles (DNPs) can be prepared with RCA and modified nucleotides that have side-chains appended on the nucleobase are capable of interacting with the DNA strands of the resulting RCA products. The incorporation of the modified nucleotides improved cellular uptake efficiency and nuclease resistance of the DNPs. We also demonstrated that these DNPs could be employed as carriers for the delivery of a photosensitizer into cancer cells to achieve photodynamic therapy upon irradiation at both the in vitro and in vivo levels.
Open AccessShaping Rolling Circle Amplification Products into DNA Nanoparticles by Incorporation of Modified Nucleotides and Their Application to In Vitro and In Vivo Delivery of a Photosensitizer
Rolling circle amplification (RCA) is a robust way to generate DNA constructs, which are promising materials for biomedical applications including drug delivery because of their high biocompatibility. To be employed as a drug delivery platform, however, the DNA materials produced by RCA need to be shaped into nanoparticles that display both high cellular uptake efficiency and nuclease resistance. Here, we showed that the DNA nanoparticles (DNPs) can be prepared with RCA and modified nucleotides that have side-chains appended on the nucleobase are capable of interacting with the DNA strands of the resulting RCA products. The incorporation of the modified nucleotides improved cellular uptake efficiency and nuclease resistance of the DNPs. We also demonstrated that these DNPs could be employed as carriers for the delivery of a photosensitizer into cancer cells to achieve photodynamic therapy upon irradiation at both the in vitro and in vivo levels.
- Open Access
Automated Dielectrophoretic Tweezers-Based Force Spectroscopy System in a Microfluidic Device
We reported an automated dielectrophoretic (DEP) tweezers-based force spectroscopy system to examine intermolecular weak binding interactions, which consists of three components: (1) interdigitated electrodes and micro-sized polystyrene particles used as DEP tweezers and probes inside a microfluidic device, along with an arbitrary function generator connected to a high voltage amplifier; (2) microscopy hooked up to a high-speed charge coupled device (CCD) camera with an image acquisition device; and (3) a computer aid control system based on the LabVIEW program. Using this automated system, we verified the measurement reliability by measuring intermolecular weak binding interactions, such as hydrogen bonds and Van der Waals interactions. In addition, we also observed the linearity of the force loading rates, which is applied to the probes by the DEP tweezers, by varying the number of voltage increment steps and thus affecting the linearity of the force loading rates. This system provides a simple and low-cost platform to investigate intermolecular weak binding interactions.
Open AccessAutomated Dielectrophoretic Tweezers-Based Force Spectroscopy System in a Microfluidic Device
We reported an automated dielectrophoretic (DEP) tweezers-based force spectroscopy system to examine intermolecular weak binding interactions, which consists of three components: (1) interdigitated electrodes and micro-sized polystyrene particles used as DEP tweezers and probes inside a microfluidic device, along with an arbitrary function generator connected to a high voltage amplifier; (2) microscopy hooked up to a high-speed charge coupled device (CCD) camera with an image acquisition device; and (3) a computer aid control system based on the LabVIEW program. Using this automated system, we verified the measurement reliability by measuring intermolecular weak binding interactions, such as hydrogen bonds and Van der Waals interactions. In addition, we also observed the linearity of the force loading rates, which is applied to the probes by the DEP tweezers, by varying the number of voltage increment steps and thus affecting the linearity of the force loading rates. This system provides a simple and low-cost platform to investigate intermolecular weak binding interactions.
- 1 November 2016
- Published by American Scientific Publishers in Journal of Nanoscience and Nanotechnology
- Vol. 16 (11) , 11793-11796
Feasibility Study of Electrical Generation Concept Based on Magnetic Nanofluid Flows
Nanotechnology has been actively applied to energy harvesting technologies by using nanoparticles and nanofluids. It has been proven that the electric power generation could be achieved via ferrohydrodynamics according to Faraday’s law of induction. It is important to control the magnetization direction of magnetic nanoparticles in a base fluid and change the magnetic flux of magnetic nanofluids with time for generating a continuous amount of electric voltage and current via ferrohydrodynamics. In this study, we proposed a novel technique for magnetic nanofluids energy harvesting using a layer-built magnet and microbubble injection. From our experiments, the microbubble in magnetic nanofluids caused time-dependent change of magnetic flux through the coil and the induced voltage was generated in the coil far more effectively according to Faraday’s law of induction. Based on computations, the time-dependent change of magnetic flux through the coil was investigated by the motion of magnetic nanoparticles and microbubbles.
- 1 November 2016
- Published by American Scientific Publishers in Journal of Nanoscience and Nanotechnology
- Vol. 16 (11) , 11793-11796
Feasibility Study of Electrical Generation Concept Based on Magnetic Nanofluid Flows
Nanotechnology has been actively applied to energy harvesting technologies by using nanoparticles and nanofluids. It has been proven that the electric power generation could be achieved via ferrohydrodynamics according to Faraday’s law of induction. It is important to control the magnetization direction of magnetic nanoparticles in a base fluid and change the magnetic flux of magnetic nanofluids with time for generating a continuous amount of electric voltage and current via ferrohydrodynamics. In this study, we proposed a novel technique for magnetic nanofluids energy harvesting using a layer-built magnet and microbubble injection. From our experiments, the microbubble in magnetic nanofluids caused time-dependent change of magnetic flux through the coil and the induced voltage was generated in the coil far more effectively according to Faraday’s law of induction. Based on computations, the time-dependent change of magnetic flux through the coil was investigated by the motion of magnetic nanoparticles and microbubbles.
- 1 October 2016
- Published by American Scientific Publishers in Journal of Nanoscience and Nanotechnology
- Vol. 16 (10) , 10965-10969
Particle Tracing Simulations of Dielectrophoretic and Magnetophoretic Flows in Magnetic Nanofluids
Alternating current breakdown voltage of magnetic nanofluids with different volume concentrations of magnetic nanoparticles was investigated and compared to that of mineral oil. The magnetic nanofluids exhibited better or worse breakdown strength compared to base fluids according to the amount of magnetic nanoparticles. However, the possible mechanisms behind the change in breakdown strength due to the amount of magnetic nanoparticles are not clearly understood. In this study, a numerical simulation of magnetic nanoparticles in an insulating fluid was developed to model particle tracing for dielectrophoretic and magnetophoretic flows in microfluidic system according to different volume concentrations of magnetic nanoparticles. Possible mechanism involved in the change of breakdown strength due to the behavior of magnetic nanoparticles was also proposed in this study.
- 1 October 2016
- Published by American Scientific Publishers in Journal of Nanoscience and Nanotechnology
- Vol. 16 (10) , 10965-10969
Particle Tracing Simulations of Dielectrophoretic and Magnetophoretic Flows in Magnetic Nanofluids
Alternating current breakdown voltage of magnetic nanofluids with different volume concentrations of magnetic nanoparticles was investigated and compared to that of mineral oil. The magnetic nanofluids exhibited better or worse breakdown strength compared to base fluids according to the amount of magnetic nanoparticles. However, the possible mechanisms behind the change in breakdown strength due to the amount of magnetic nanoparticles are not clearly understood. In this study, a numerical simulation of magnetic nanoparticles in an insulating fluid was developed to model particle tracing for dielectrophoretic and magnetophoretic flows in microfluidic system according to different volume concentrations of magnetic nanoparticles. Possible mechanism involved in the change of breakdown strength due to the behavior of magnetic nanoparticles was also proposed in this study.
- 11 June 2015
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 19 (4) , 777-786
Timescale analysis for estimating upper limit perfusion rate in a microfluidic perfusion cell culture platform
- 11 June 2015
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 19 (4) , 777-786
Timescale analysis for estimating upper limit perfusion rate in a microfluidic perfusion cell culture platform
- 10 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 51 (11) , 1-4
Power Generation Using Magnetic Nanofluids in Millimeter-Sized Channel With In-Phase Mode of Magnetization
Magnetic nanofluids (MNFs) are an interesting energy harvesting source. In this paper, the flow energy harvesting was experimentally and numerically investigated in a millimeter-sized channel using an externally applied permanent magnet to control the magnetizing direction of the magnetic nanoparticles (MNPs). Oil- or water-based MNF includes a certain percentage of magnetized nanoparticles and has unique features that vary with the strength of the external electromagnetic field. When the MNF flows through a cross-sectional area of the coil loop, the electromotive force can be obtained by following Faraday's law, because the MNPs act as permanent magnets. When the MNFs are used for flow energy harvesting, the main issue is the in-phase mode alignment of the MNPs magnetization with the coil loop. Without the in-phase mode, the electric power cannot be generated, because the net magnetization of the MNF is zero. Most of the previous research works, however, have not considered it. Thus, to implement this mode, we proposed an externally applied magnetic field generated by a cylindrically shaped permanent magnet. Short and closed Teflon tubing with a 1.5 mm inner diameter, containing the MNF, was located inside long silicon tubing and moved along the positive and negative directions by a pump. Then, the generated voltages were measured, and exhibited similar results to those obtained analytically. In the same way, we calculated and experimentally tested a chain type of Teflon tubing.
- 10 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 51 (11) , 1-4
Power Generation Using Magnetic Nanofluids in Millimeter-Sized Channel With In-Phase Mode of Magnetization
Magnetic nanofluids (MNFs) are an interesting energy harvesting source. In this paper, the flow energy harvesting was experimentally and numerically investigated in a millimeter-sized channel using an externally applied permanent magnet to control the magnetizing direction of the magnetic nanoparticles (MNPs). Oil- or water-based MNF includes a certain percentage of magnetized nanoparticles and has unique features that vary with the strength of the external electromagnetic field. When the MNF flows through a cross-sectional area of the coil loop, the electromotive force can be obtained by following Faraday's law, because the MNPs act as permanent magnets. When the MNFs are used for flow energy harvesting, the main issue is the in-phase mode alignment of the MNPs magnetization with the coil loop. Without the in-phase mode, the electric power cannot be generated, because the net magnetization of the MNF is zero. Most of the previous research works, however, have not considered it. Thus, to implement this mode, we proposed an externally applied magnetic field generated by a cylindrically shaped permanent magnet. Short and closed Teflon tubing with a 1.5 mm inner diameter, containing the MNF, was located inside long silicon tubing and moved along the positive and negative directions by a pump. Then, the generated voltages were measured, and exhibited similar results to those obtained analytically. In the same way, we calculated and experimentally tested a chain type of Teflon tubing.
- 17 August 2012
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 22 (9) , 95019
Lithography-free centimeter-long nanochannel fabrication method using an electrospun nanofiber array
- 17 August 2012
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 22 (9) , 95019
Lithography-free centimeter-long nanochannel fabrication method using an electrospun nanofiber array