Kazem Khiabani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kazem Khiabani has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Seied Omid Keyhan
College of Medicine
6 shared publications Mohammad Hosein Amirzade-Iranaq
Postgraduate Student, Student Research Committee, Department of Oral Medicine, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
5 shared publications- Seifollah Hemmat
Assistant Professor, Department of Oral and Maxillofacial Surgery, Bandar Abbas University of Medical Science, Bandar Abbas, Iran
4 shared publications - Mohammad Hosein Amirzade-Iranaq
Department of Oral and Maxillofacial Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
3 shared publications Payam Varedi
Chief Resident, Department of Oral and Maxillofacial Surgery, Craniomaxillofacial Research Center, Shariati Hospital, Tehran University of Medical Sciences, Tehran, Iran
3 shared publicationsAmir Ali Badri
2 shared publications
Latest Publications
- Open Access
- 1 June 2026
- Published by Wolters Kluwer Health in Dental Research Journal
- Vol. 23 (6)
Does the biplane three-dimensional miniplate design provide stable fixation for mandibular angle fractures? A clinical study and proposal for novel radiographic criteria
Background: The posterior anatomical position and complex biomechanics of mandibular angle fractures (MAF) make their management more complicated than other mandibular fractures. The shortcomings of semi-rigid and rigid fixations have led to the development of a biplane three-dimensional (3D) miniplate design to fixate angle fractures in two perpendicular planes. The aim is to determine whether using a Biplane 3D miniplate could provide a feasible, effective, and reliable fixation for displaced MAFs. Materials and Methods: This prospective, quasi-experimental, clinical study was conducted on adult patients with displaced MAFs. The primary outcome (occlusion) and secondary clinical outcomes (fracture stability and adequate mouth opening) were recorded in the first 2 weeks and the 2 nd and 6 th months postoperative. Appropriate reduction (secondary outcome) was assessed with novel radiographic criteria in the vertical and horizontal planes. Statistical analysis was performed using SPSS version 22 and included Fisher’s exact and Chi-square tests. The level of significance was set at P < 0.05. Results: Twenty-one patients with MAFs (nine isolated fractures) were operated on and followed for 3-6 months (mean: 4.95 months). Only two cases (9.52%) in the nonisolated fracture group showed mild occlusal derangement, which resolved with heavy elastic therapy. Adequate mouth opening was gradually resumed in both groups within the 1 st month. No postfixation complications were observed. Radiographic criteria measurement revealed 14.29% and 28.6% mild vertical and horizontal radiographic malalignment without detectable clinical signs. Conclusion: Biplane 3D miniplate fixation shows promising results in the management of MAFs with minimal complications, suggesting that it is safe and effective. Concomitant management of displaced mandibular fractures does not seem to affect treatment outcomes.
- 1 June 2026
- Published by Wolters Kluwer Health in Dental Research Journal
- Vol. 23 (6)
Open AccessDoes the biplane three-dimensional miniplate design provide stable fixation for mandibular angle fractures? A clinical study and proposal for novel radiographic criteria
Background: The posterior anatomical position and complex biomechanics of mandibular angle fractures (MAF) make their management more complicated than other mandibular fractures. The shortcomings of semi-rigid and rigid fixations have led to the development of a biplane three-dimensional (3D) miniplate design to fixate angle fractures in two perpendicular planes. The aim is to determine whether using a Biplane 3D miniplate could provide a feasible, effective, and reliable fixation for displaced MAFs. Materials and Methods: This prospective, quasi-experimental, clinical study was conducted on adult patients with displaced MAFs. The primary outcome (occlusion) and secondary clinical outcomes (fracture stability and adequate mouth opening) were recorded in the first 2 weeks and the 2 nd and 6 th months postoperative. Appropriate reduction (secondary outcome) was assessed with novel radiographic criteria in the vertical and horizontal planes. Statistical analysis was performed using SPSS version 22 and included Fisher’s exact and Chi-square tests. The level of significance was set at P < 0.05. Results: Twenty-one patients with MAFs (nine isolated fractures) were operated on and followed for 3-6 months (mean: 4.95 months). Only two cases (9.52%) in the nonisolated fracture group showed mild occlusal derangement, which resolved with heavy elastic therapy. Adequate mouth opening was gradually resumed in both groups within the 1 st month. No postfixation complications were observed. Radiographic criteria measurement revealed 14.29% and 28.6% mild vertical and horizontal radiographic malalignment without detectable clinical signs. Conclusion: Biplane 3D miniplate fixation shows promising results in the management of MAFs with minimal complications, suggesting that it is safe and effective. Concomitant management of displaced mandibular fractures does not seem to affect treatment outcomes.
- 19 December 2023
- Published by Springer Nature in Current Fungal Infection Reports
- Vol. 17 (4) , 282-295
An Update on COVID‐19 Associated Mucormycosis Characteristics, Risk Factors, and Outcomes: a Systematic Review and Meta-Analysis
- 19 December 2023
- Published by Springer Nature in Current Fungal Infection Reports
- Vol. 17 (4) , 282-295
An Update on COVID‐19 Associated Mucormycosis Characteristics, Risk Factors, and Outcomes: a Systematic Review and Meta-Analysis
- Open Access
- 6 November 2023
- Published by Brieflands in Jundishapur Journal of Microbiology
- Vol. 16 (9)
Assessment of Salivary Glands as Reservoirs of SARS-CoV-2 and the Contagiousness of Saliva in Asymptomatic COVID-19 Patients: Is Delta Variant More Contagious?
Background: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection transmits when aerosols or droplets containing the virus are inhaled or come directly into contact, mainly in close contact with an infected person. Objectives: This study aimed to evaluate the role of the salivary glands in the secretion of SARS-CoV-2-infected saliva and determine the contagiousness of saliva in asymptomatic coronavirus disease 2019 (COVID-19) patients. Methods: In this cross-sectional analytical study between March 2021 and March 2022, 85 asymptomatic COVID-19 individuals with positive nasopharyngeal/oropharyngeal swabs were recruited. The SARS-CoV-2 cycle threshold (Ct) value was investigated in concomitant nasopharyngeal swabs (NPS), saliva, and pure saliva (collected directly from the salivary duct opening) using Real Time-PCR assay. Statistical analysis was performed using SPSS software (version 23), and a p-value of < 0.05 was considered significant. Results: The saliva Ct-value was the lowest (the highest viral load) for Delta (29.82 ± 4.66), Omicron (32.75 ± 4.82), and Alpha (36.83 ± 4.8) variants, respectively. Delta-infected saliva and pure saliva revealed the strongest correlation (correlation coefficient = 0.971, P < 0.001). Saliva Ct-value was significantly lower in Delta- (P < 0.001) and Omicron- (P = 0.012) infected patients than in Alpha-infected patients. The pure saliva Ct-value was significantly lower (P = 0.014) in Delta samples (30.13 ± 4.51). Asymptomatic Alpha- and Omicron-infected patients revealed significantly lower NPS Ct-value (30.52 ± 4.02 and 29.44 ± 3.34) than the saliva (36.83 ± 4.8 and 32.75 ± 4.82). Conclusions: The major salivary glands secrete SARS-CoV-2-infected saliva in nearly all Delta-infected and most Omicron-infected asymptomatic individuals. Although the transmission process is complex, saliva droplets and aerosols seem to have a higher contagiousness potential in individuals infected with the Delta variant.
- 6 November 2023
- Published by Brieflands in Jundishapur Journal of Microbiology
- Vol. 16 (9)
Open AccessAssessment of Salivary Glands as Reservoirs of SARS-CoV-2 and the Contagiousness of Saliva in Asymptomatic COVID-19 Patients: Is Delta Variant More Contagious?
Background: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection transmits when aerosols or droplets containing the virus are inhaled or come directly into contact, mainly in close contact with an infected person. Objectives: This study aimed to evaluate the role of the salivary glands in the secretion of SARS-CoV-2-infected saliva and determine the contagiousness of saliva in asymptomatic coronavirus disease 2019 (COVID-19) patients. Methods: In this cross-sectional analytical study between March 2021 and March 2022, 85 asymptomatic COVID-19 individuals with positive nasopharyngeal/oropharyngeal swabs were recruited. The SARS-CoV-2 cycle threshold (Ct) value was investigated in concomitant nasopharyngeal swabs (NPS), saliva, and pure saliva (collected directly from the salivary duct opening) using Real Time-PCR assay. Statistical analysis was performed using SPSS software (version 23), and a p-value of < 0.05 was considered significant. Results: The saliva Ct-value was the lowest (the highest viral load) for Delta (29.82 ± 4.66), Omicron (32.75 ± 4.82), and Alpha (36.83 ± 4.8) variants, respectively. Delta-infected saliva and pure saliva revealed the strongest correlation (correlation coefficient = 0.971, P < 0.001). Saliva Ct-value was significantly lower in Delta- (P < 0.001) and Omicron- (P = 0.012) infected patients than in Alpha-infected patients. The pure saliva Ct-value was significantly lower (P = 0.014) in Delta samples (30.13 ± 4.51). Asymptomatic Alpha- and Omicron-infected patients revealed significantly lower NPS Ct-value (30.52 ± 4.02 and 29.44 ± 3.34) than the saliva (36.83 ± 4.8 and 32.75 ± 4.82). Conclusions: The major salivary glands secrete SARS-CoV-2-infected saliva in nearly all Delta-infected and most Omicron-infected asymptomatic individuals. Although the transmission process is complex, saliva droplets and aerosols seem to have a higher contagiousness potential in individuals infected with the Delta variant.
- Open Access
- 29 March 2023
- Published by Elsevier in Oral and Maxillofacial Surgery Cases
- Vol. 9 (2)
Maxillomandibular fixation miniplate, alternative management for condylar fractures in complete/partial edentulous mandible
- 29 March 2023
- Published by Elsevier in Oral and Maxillofacial Surgery Cases
- Vol. 9 (2)
Open AccessMaxillomandibular fixation miniplate, alternative management for condylar fractures in complete/partial edentulous mandible
- 1 March 2023
- Published by Quintessence Publishing in The International Journal of Oral and Maxillofacial Implants
- Vol. 38 (2) , 303-312
Less Invasive Window Repositioning Technique for Sinus Floor Elevation: A Clinical and Radiographic Study
Kazem Khiabani, DMD, OMFS/Mohammad Hosein Amirzade-Iranaq, DDS/Ehsan Mostajeran, DMD, OMFS: Purpose: To determine whether a less invasive window repositioning technique could provide a feasible, safe, and reliable lateral sinus augmentation. Materials and Methods: The less-invasive window repositioning technique using a piezoelectric saw was performed on adult patient candidates for lateral sinus floor elevation. The augmented bone height (primary outcome variable), bone length, and posthealing outcome variables were evaluated to determine the augmentation adequacy, safety, and reliability of this technique overall and in one- and two-implant groups with different window dimensions. Data were analyzed using descriptive statistics, chi-square test, and Pearson correlation analysis. P < .05 was considered significant. Results: A total of 50 consecutive sinus floor elevations with simultaneous placement of 66 implants (one-implant: 34, two-implant: 16) were performed on 44 subjects (72% men) with a mean age of 46.7 ± 10.3 years and followed for a mean of 13.28 ± 3.5 months. The overall, one-implant, and two-implant group mean window sizes were 31.38 ± 6.78 mm2, 28.38 ± 4.2 mm2, and 37.75 ± 6.88 mm2, respectively. The mean overall augmented bone height and length were 12.3 ± 1.04 mm and 19.67 ± 2.01 mm, respectively. The mean window size was significantly smaller in the one-implant group versus the two-implant group (P < .001). However, there was no correlation between window size and augmented bone height (r = ?0.9, P = .54) and length (r = 0.05, P = .68). The posthealing outcome variables showed perfect window integration without soft tissue ingrowth. Six sinus perforations (12%) during membrane elevation that were not related to window osteotomy were observed and were appropriately managed. Conclusion: The less-invasive window repositioning technique is feasible, safe, and reliable for appropriate sinus augmentation in height and length. The reduction of window dimension does not influence the feasibility, augmentation adequacy, and surgical safety and does not increase surgical risks or membrane perforation. The repositioned window showed proper integration. Also, sinus floor elevation through this technique is an experience-based surgery that requires delicate instruments.
- 1 March 2023
- Published by Quintessence Publishing in The International Journal of Oral and Maxillofacial Implants
- Vol. 38 (2) , 303-312
Less Invasive Window Repositioning Technique for Sinus Floor Elevation: A Clinical and Radiographic Study
Kazem Khiabani, DMD, OMFS/Mohammad Hosein Amirzade-Iranaq, DDS/Ehsan Mostajeran, DMD, OMFS: Purpose: To determine whether a less invasive window repositioning technique could provide a feasible, safe, and reliable lateral sinus augmentation. Materials and Methods: The less-invasive window repositioning technique using a piezoelectric saw was performed on adult patient candidates for lateral sinus floor elevation. The augmented bone height (primary outcome variable), bone length, and posthealing outcome variables were evaluated to determine the augmentation adequacy, safety, and reliability of this technique overall and in one- and two-implant groups with different window dimensions. Data were analyzed using descriptive statistics, chi-square test, and Pearson correlation analysis. P < .05 was considered significant. Results: A total of 50 consecutive sinus floor elevations with simultaneous placement of 66 implants (one-implant: 34, two-implant: 16) were performed on 44 subjects (72% men) with a mean age of 46.7 ± 10.3 years and followed for a mean of 13.28 ± 3.5 months. The overall, one-implant, and two-implant group mean window sizes were 31.38 ± 6.78 mm2, 28.38 ± 4.2 mm2, and 37.75 ± 6.88 mm2, respectively. The mean overall augmented bone height and length were 12.3 ± 1.04 mm and 19.67 ± 2.01 mm, respectively. The mean window size was significantly smaller in the one-implant group versus the two-implant group (P < .001). However, there was no correlation between window size and augmented bone height (r = ?0.9, P = .54) and length (r = 0.05, P = .68). The posthealing outcome variables showed perfect window integration without soft tissue ingrowth. Six sinus perforations (12%) during membrane elevation that were not related to window osteotomy were observed and were appropriately managed. Conclusion: The less-invasive window repositioning technique is feasible, safe, and reliable for appropriate sinus augmentation in height and length. The reduction of window dimension does not influence the feasibility, augmentation adequacy, and surgical safety and does not increase surgical risks or membrane perforation. The repositioned window showed proper integration. Also, sinus floor elevation through this technique is an experience-based surgery that requires delicate instruments.
- 1 December 2021
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 79 (12) , 2411-2420
Does Minimal-Invasive Envelope Flap Reduce Side Effects Compared to Conventional Envelope Flap Following Impacted Third Molar Surgery? A Split-Mouth Randomized Clinical Trial
- 1 December 2021
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 79 (12) , 2411-2420
Does Minimal-Invasive Envelope Flap Reduce Side Effects Compared to Conventional Envelope Flap Following Impacted Third Molar Surgery? A Split-Mouth Randomized Clinical Trial
- 1 September 2021
- Published by Elsevier in American Journal of Infection Control
- Vol. 49 (9) , 1165-1176
Are saliva and deep throat sputum as reliable as common respiratory specimens for SARS-CoV-2 detection? A systematic review and meta-analysis
- 1 September 2021
- Published by Elsevier in American Journal of Infection Control
- Vol. 49 (9) , 1165-1176
Are saliva and deep throat sputum as reliable as common respiratory specimens for SARS-CoV-2 detection? A systematic review and meta-analysis
- 8 November 2017
- Published by Bentham Science Publishers Ltd. in Reviews on Recent Clinical Trials
- Vol. 12 (3) , 154-158
Customized Titanium Mesh Based on the 3D Printed Model vs. Manual Intraoperative Bending of Titanium Mesh for Reconstructing of Orbital Bone Fracture: A Randomized Clinical Trial
Background: This study was aimed to compare the efficacy of customized patient-specific titanium mesh based on 3D printed model with intra-operative bending of titanium mesh for reconstructing of orbital floor fracture. Methods: This study was prospectively conducted on 10 patients with unilateral orbital floor fractures caused by accident or falls. In intervention group (n=5), the CT-scan slices were used for generating 3D reconstruction of both affected and unaffected orbits. Then, a 3D printed template of mirrored unaffected orbit was produced to mold the titanium mesh. The titanium mesh in conventional group (n=5) was bended only manually and intraoperatively by surgeon and positioned over the bony defect. All patients were followed-up within 1 week, 1 month and 4 months after surgery for assessing enophthalmos, diplopia and other complications. Results: Of 10 patients of the study only two patients in intervention group had preoperative vertical dystopia or diplopia which had been resolved after intervention. The mean enophthalmos at baseline and 1 week, 1 month and 4 months after surgery in control group were 3.8±0.7, 2.4±0.8, 2.4±0.8, and 2.4±0.8 mm, respectively, and in intervention group were 2.6±0.8, 0.35 ± 0.4, 0.35 ± 0.4 and 0.35 ± 0.4 mm, respectively. The mean enophthalmos did not differ significantly at baseline between two groups, while two groups showed significant difference after surgery. Conclusion: Finally, we concluded that the placement of patient-specific titanium implant for reconstructing of orbital bone fracture led to better outcomes when compared to manual bending in terms of enophthalmos and other complications.
- 8 November 2017
- Published by Bentham Science Publishers Ltd. in Reviews on Recent Clinical Trials
- Vol. 12 (3) , 154-158
Customized Titanium Mesh Based on the 3D Printed Model vs. Manual Intraoperative Bending of Titanium Mesh for Reconstructing of Orbital Bone Fracture: A Randomized Clinical Trial
Background: This study was aimed to compare the efficacy of customized patient-specific titanium mesh based on 3D printed model with intra-operative bending of titanium mesh for reconstructing of orbital floor fracture. Methods: This study was prospectively conducted on 10 patients with unilateral orbital floor fractures caused by accident or falls. In intervention group (n=5), the CT-scan slices were used for generating 3D reconstruction of both affected and unaffected orbits. Then, a 3D printed template of mirrored unaffected orbit was produced to mold the titanium mesh. The titanium mesh in conventional group (n=5) was bended only manually and intraoperatively by surgeon and positioned over the bony defect. All patients were followed-up within 1 week, 1 month and 4 months after surgery for assessing enophthalmos, diplopia and other complications. Results: Of 10 patients of the study only two patients in intervention group had preoperative vertical dystopia or diplopia which had been resolved after intervention. The mean enophthalmos at baseline and 1 week, 1 month and 4 months after surgery in control group were 3.8±0.7, 2.4±0.8, 2.4±0.8, and 2.4±0.8 mm, respectively, and in intervention group were 2.6±0.8, 0.35 ± 0.4, 0.35 ± 0.4 and 0.35 ± 0.4 mm, respectively. The mean enophthalmos did not differ significantly at baseline between two groups, while two groups showed significant difference after surgery. Conclusion: Finally, we concluded that the placement of patient-specific titanium implant for reconstructing of orbital bone fracture led to better outcomes when compared to manual bending in terms of enophthalmos and other complications.
- Open Access
- 8 January 2017
- Published by Maad Rayan Publishing Company in Journal of lasers in medical sciences
- Vol. 8 (1) , 42-45
Assessment of Low-Level Laser Therapy Effects After Extraction of Impacted Lower Third Molar Surgery
Assessment of Low-Level Laser Therapy Effects After Extraction of Impacted Lower Third Molar Surgery
- 8 January 2017
- Published by Maad Rayan Publishing Company in Journal of lasers in medical sciences
- Vol. 8 (1) , 42-45
Open AccessAssessment of Low-Level Laser Therapy Effects After Extraction of Impacted Lower Third Molar Surgery
Assessment of Low-Level Laser Therapy Effects After Extraction of Impacted Lower Third Molar Surgery