Thomas Gessner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Thomas Gessner has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Thomas Otto
Fraunhofer Institute for Electronic Nano Systems ENAS, Chemnitz, Germany
8 shared publications Volker Stock
TQ Systems GmbH (Germany)
4 shared publicationsRay Saupe
Fraunhofer-Institut für Elektronische Nanosysteme (Germany)
3 shared publications- Stefan E. Schulz
Center for Microtechnologies, Chemnitz University of Technology, 09107 Chemnitz, Germany
3 shared publications Uwe Fritzsch
COLOUR CONTROL Farbmesstechnik GmbH (Germany)
3 shared publications- Bernhard Wunderle
Faculty of Electrical Engineering and Information Technology, Chemnitz University of Technology, Reichenhainer Str. 70, 09126 Chemnitz, Germany
2 shared publications
Latest Publications
- Open Access
- 13 September 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (9) , 153
Integration of an Optical Ring Resonator Biosensor into a Self-Contained Microfluidic Cartridge with Active, Single-Shot Micropumps
While there have been huge advances in the field of biosensors during the last decade, their integration into a microfluidic environment avoiding external tubing and pumping is still neglected. Herein, we show a new microfluidic design that integrates multiple reservoirs for reagent storage and single-use electrochemical pumps for time-controlled delivery of the liquids. The cartridge has been tested and validated with a silicon nitride-based photonic biosensor incorporating multiple optical ring resonators as sensing elements and an immunoassay as a potential target application. Based on experimental results obtained with a demonstration model, subcomponents were designed and existing protocols were adapted. The newly-designed microfluidic cartridges and photonic sensors were separately characterized on a technical basis and performed well. Afterwards, the sensor was functionalized for a protein detection. The microfluidic cartridge was loaded with the necessary assay reagents. The integrated pumps were programmed to drive the single process steps of an immunoassay. The prototype worked selectively, but only with a low sensitivity. Further work must be carried out to optimize biofunctionalization of the optical ring resonators and to have a more suitable flow velocity progression to enhance the system’s reproducibility.
- 13 September 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (9) , 153
Open AccessIntegration of an Optical Ring Resonator Biosensor into a Self-Contained Microfluidic Cartridge with Active, Single-Shot Micropumps
While there have been huge advances in the field of biosensors during the last decade, their integration into a microfluidic environment avoiding external tubing and pumping is still neglected. Herein, we show a new microfluidic design that integrates multiple reservoirs for reagent storage and single-use electrochemical pumps for time-controlled delivery of the liquids. The cartridge has been tested and validated with a silicon nitride-based photonic biosensor incorporating multiple optical ring resonators as sensing elements and an immunoassay as a potential target application. Based on experimental results obtained with a demonstration model, subcomponents were designed and existing protocols were adapted. The newly-designed microfluidic cartridges and photonic sensors were separately characterized on a technical basis and performed well. Afterwards, the sensor was functionalized for a protein detection. The microfluidic cartridge was loaded with the necessary assay reagents. The integrated pumps were programmed to drive the single process steps of an immunoassay. The prototype worked selectively, but only with a low sensitivity. Further work must be carried out to optimize biofunctionalization of the optical ring resonators and to have a more suitable flow velocity progression to enhance the system’s reproducibility.
- 7 March 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8977
A new generation of MEMS middle-infrared spectrometers
Mid infrared spectroscopy has been developed to a powerful and essential method of material analysis, with a steadily increasing number of industrial and scientific application fields. The so called spectral fingerprint range enables identification of chemical compounds by their unique spectral pattern. To provide a suitable miniaturized and portable MIR spectrometer solution at an affordable price, an existing MEMS NIR spectrometer module which already bases on micro system technology has been expanded in its wavelength range. The developed spectrometer belongs to the category of scanning grating spectrometers. Main component is a fast oscillating micro-mirror which moves sinusoidal with high mechanical precision enabling a high stability of according wavelength axis. This is supported by a highly precise optical tracking of the actual motion. Mono-crystalline silicon guarantees a long-life operation with no wear even under harsh environmental conditions. Spectral signal acquisition is realized by using a TE-cooled MCT single element detector assisted by low noise trans-impedance amplifier. With the help of integrated logic components a data pre-processing takes place, such as averaging, offset subtraction, detector transfer characteristic correction and noise shaping. Due the compact and flexible setup, the spectrometer is suitable for the use in various applications, such as process control in chemical industry, gas mixture analysis or liquid verification. The portability of the device opens up new application possibilities in mobile environment. The advances of the promising technology and its specific applications will be described in this paper. Advanced performance issues of the device be reviewed in detail.
- 7 March 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8977
A new generation of MEMS middle-infrared spectrometers
Mid infrared spectroscopy has been developed to a powerful and essential method of material analysis, with a steadily increasing number of industrial and scientific application fields. The so called spectral fingerprint range enables identification of chemical compounds by their unique spectral pattern. To provide a suitable miniaturized and portable MIR spectrometer solution at an affordable price, an existing MEMS NIR spectrometer module which already bases on micro system technology has been expanded in its wavelength range. The developed spectrometer belongs to the category of scanning grating spectrometers. Main component is a fast oscillating micro-mirror which moves sinusoidal with high mechanical precision enabling a high stability of according wavelength axis. This is supported by a highly precise optical tracking of the actual motion. Mono-crystalline silicon guarantees a long-life operation with no wear even under harsh environmental conditions. Spectral signal acquisition is realized by using a TE-cooled MCT single element detector assisted by low noise trans-impedance amplifier. With the help of integrated logic components a data pre-processing takes place, such as averaging, offset subtraction, detector transfer characteristic correction and noise shaping. Due the compact and flexible setup, the spectrometer is suitable for the use in various applications, such as process control in chemical industry, gas mixture analysis or liquid verification. The portability of the device opens up new application possibilities in mobile environment. The advances of the promising technology and its specific applications will be described in this paper. Advanced performance issues of the device be reviewed in detail.
- 1 January 2014
- Published by Laser Institute of America
Laser based dry integration of rolled-up nanomembranes into polymer substrates
- 1 January 2014
- Published by Laser Institute of America
Laser based dry integration of rolled-up nanomembranes into polymer substrates
- Open Access
- 11 January 2013
- Published by Springer Nature in Discover Nano
- Vol. 8 (1) , 24
Conductive AFM for CNT characterization
We report on and emphasize the versatility of conductive atomic force microscopy in characterizing vertically aligned carbon nanotubes (CNTs) aimed to be used in via interconnect technology. The study is conducted on multi-walled CNT arrays vertically grown on a copper-based metal line. Voltage-dependent current mapping and current–voltage characteristics recorded down to single CNT allow for a comprehensive insight into the electric behaviour of the hybrid structure.
- 11 January 2013
- Published by Springer Nature in Discover Nano
- Vol. 8 (1) , 24
Open AccessConductive AFM for CNT characterization
We report on and emphasize the versatility of conductive atomic force microscopy in characterizing vertically aligned carbon nanotubes (CNTs) aimed to be used in via interconnect technology. The study is conducted on multi-walled CNT arrays vertically grown on a copper-based metal line. Voltage-dependent current mapping and current–voltage characteristics recorded down to single CNT allow for a comprehensive insight into the electric behaviour of the hybrid structure.
- 9 February 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8264
Nanosensor technology based on semiconductor nanocrystals
We present a new concept of material integrated sensor technology for detection, storage and visualization of mechanical stress and load conditions. Key feature is a double layer consisting of a piezoelectric layer and a semiconductor nanocrystal polymer composite film. Electrical charges are generated within the piezo layer by application of a mechanical load to the structure. The charges are transferred to the composite film and injected into the nanocrystals, causing non-radiative exciton recombination. This results in photoluminescence quenching, which can be detected as local optical contrast. The photoluminescence of CdSe/ZnS core/shell quantum dots has been switched off by application of external voltages smaller than 20 V. It was possible to store the charges in the QDs, and hence the off-state, for several hours. Optical contrast ratios up to 1:125 have been detected so far.
- 9 February 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8264
Nanosensor technology based on semiconductor nanocrystals
We present a new concept of material integrated sensor technology for detection, storage and visualization of mechanical stress and load conditions. Key feature is a double layer consisting of a piezoelectric layer and a semiconductor nanocrystal polymer composite film. Electrical charges are generated within the piezo layer by application of a mechanical load to the structure. The charges are transferred to the composite film and injected into the nanocrystals, causing non-radiative exciton recombination. This results in photoluminescence quenching, which can be detected as local optical contrast. The photoluminescence of CdSe/ZnS core/shell quantum dots has been switched off by application of external voltages smaller than 20 V. It was possible to store the charges in the QDs, and hence the off-state, for several hours. Optical contrast ratios up to 1:125 have been detected so far.
- 31 August 2011
- Published by Elsevier in Microelectronic Engineering
- Vol. 88 (8) , 1978-1981
Variable-shaped e-beam lithography enabling process development for future copper damascene technology
- 31 August 2011
- Published by Elsevier in Microelectronic Engineering
- Vol. 88 (8) , 1978-1981
Variable-shaped e-beam lithography enabling process development for future copper damascene technology
- 1 January 2011
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 158 (12) , H1228-H1232
The Inhibition of Enhanced Cu Oxidation on Ruthenium∕Diffusion Barrier Layers for Cu Interconnects by Carbon Alloying into Ru
The inhibition of Cu oxidation by alloying C into the Ru/TaN barrier stack is investigated. By using in-situ XRD measurement, severe copper oxide formation was observed for the Cu/Ru/barrier system during annealing process in He atmosphere. This phenomenon is explained using thermodynamics from the viewpoint of Gibbs free energy of oxide formation. The Cu oxidation can be inhibited by alloying C into the Ru layer, and the more C content in the RuC layer, the more evident the inhibition effect. The RuC/TaN stack also shows better diffusion barrier properties than the Ru/TaN bi-layer. Atomic layer deposition of Cu2O on the RuC substrate was carried out and reduction of the Cu2O to Cu was observed. The mechanism of inhibition of Cu oxidation on C alloyed Ru was investigated by a first principles calculation based on the density functional theory.
- 1 January 2011
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 158 (12) , H1228-H1232
The Inhibition of Enhanced Cu Oxidation on Ruthenium∕Diffusion Barrier Layers for Cu Interconnects by Carbon Alloying into Ru
The inhibition of Cu oxidation by alloying C into the Ru/TaN barrier stack is investigated. By using in-situ XRD measurement, severe copper oxide formation was observed for the Cu/Ru/barrier system during annealing process in He atmosphere. This phenomenon is explained using thermodynamics from the viewpoint of Gibbs free energy of oxide formation. The Cu oxidation can be inhibited by alloying C into the Ru layer, and the more C content in the RuC layer, the more evident the inhibition effect. The RuC/TaN stack also shows better diffusion barrier properties than the Ru/TaN bi-layer. Atomic layer deposition of Cu2O on the RuC substrate was carried out and reduction of the Cu2O to Cu was observed. The mechanism of inhibition of Cu oxidation on C alloyed Ru was investigated by a first principles calculation based on the density functional theory.
- 6 June 2009
- Published by Springer Nature
- p. 33-62
Smart Integrated Systems: From Components to Products
- 6 June 2009
- Published by Springer Nature
- p. 33-62
Smart Integrated Systems: From Components to Products