Antonino Santi Delia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Antonino Santi Delia has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Pasqualina Laganà
Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, 98122 Messina, Italy
9 shared publications - Gabriella Caruso
Institute of Polar Sciences, National Research Council (CNR-ISP), Spianata S. Raineri 86, 98122 Messina, Italy
4 shared publications - Giorgia Caruso
Industrial Consultant
4 shared publications - Salvatore Parisi
Lourdes Matha Institute of Hotel Management and Catering Technology
4 shared publications - Alessio Facciolà
Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, Via C. Valeria, I-98100 Messina, Italy
3 shared publications - Osvalda De Giglio
Interdisciplinary Department of Medicine, Hygiene Section, University of Bari Aldo Moro, 70124 Bari, Italy
3 shared publications
Latest Publications
- Open Access
- 15 December 2023
- Published by MDPI AG in Microorganisms
- Vol. 11 (12) , 2992
The Presence of Legionella in Water Used for Car Washing: Implications for Public Health
Although today all of the aspects of Legionella are better understood than in the past, in many countries the interest is still mainly focused on healthcare and tourism facilities. Other at-risk areas are less explored, such as those where workers are often in contact with water during their activities. In reality, any water system capable of producing aerosols can be considered a potential source of Legionella transmission, including car washes, where a large number of users work and flow through annually. From January to May 2022, 120 samples were carried out in 30 car washes located in Messina (Italy): 60 samples of water and 60 of aerosols. The aim of this investigation was to evaluate the risk of legionellosis in car washing workers exposed to potentially contaminated aerosols. To increase the probability of finding Legionella, the sample collections were organized on different days of the week. Of the total samples taken, 10 (8.3%) were positive for Legionella: seven (11.7%) water (range 100–1000 CFU) and three (5%) aerosol (range 10–150 CFU) samples. Detected serogroups were L. pneumophila sgr 1, 7, 10 and Legionella gormanii. Given the results obtained, preventative measures should be implemented in such facilities in order to protect the health of users and car wash operators.
- 15 December 2023
- Published by MDPI AG in Microorganisms
- Vol. 11 (12) , 2992
Open AccessThe Presence of Legionella in Water Used for Car Washing: Implications for Public Health
Although today all of the aspects of Legionella are better understood than in the past, in many countries the interest is still mainly focused on healthcare and tourism facilities. Other at-risk areas are less explored, such as those where workers are often in contact with water during their activities. In reality, any water system capable of producing aerosols can be considered a potential source of Legionella transmission, including car washes, where a large number of users work and flow through annually. From January to May 2022, 120 samples were carried out in 30 car washes located in Messina (Italy): 60 samples of water and 60 of aerosols. The aim of this investigation was to evaluate the risk of legionellosis in car washing workers exposed to potentially contaminated aerosols. To increase the probability of finding Legionella, the sample collections were organized on different days of the week. Of the total samples taken, 10 (8.3%) were positive for Legionella: seven (11.7%) water (range 100–1000 CFU) and three (5%) aerosol (range 10–150 CFU) samples. Detected serogroups were L. pneumophila sgr 1, 7, 10 and Legionella gormanii. Given the results obtained, preventative measures should be implemented in such facilities in order to protect the health of users and car wash operators.
- Open Access
Legionella spp. in Thermal Facilities: A Public Health Issue in the One Health Vision
Thermal facilities comprise a wide spectrum of recreational and therapeutic activities with the number of customers increasing over time despite the break that occurred during the first phases of the COVID-19 pandemic. In order to evaluate the potential role played by this setting in the risk of contracting legionellosis, we conducted a cross-sectional study to evaluate the presence of Legionella spp. in some Italian thermal facilities. Specifically, we retrospectively analyzed the results of a 16-year surveillance carried out before the COVID-19 pandemic. Of 409 samples, 70 (17.1%) were positive with Legionella spp. but there was an overall decrease over time. L. pneumophila 2–14 were by far the most common detected serotypes, while L. pneumophila 1 accounted for only 8.8%. Of all the different kind of samples, swabs and municipal water samples were the most contaminated. Moreover, in the positive samples, bacterial load was often at intermediate values. In only a small percentage of samples was load high and, in this case, L. pneumophila 1 was often the most common strain. Our results show the importance of a continuous monitoring of Legionella risk in these settings, even more so now after the COVID-19 pandemic and the prolonged break in activities. Water is the natural environment of Legionella spp. and environment in general plays a crucial role in the transmission of these bacteria; therefore, it would be useful to frame this infection in a “One Health” key.
Open AccessLegionella spp. in Thermal Facilities: A Public Health Issue in the One Health Vision
Thermal facilities comprise a wide spectrum of recreational and therapeutic activities with the number of customers increasing over time despite the break that occurred during the first phases of the COVID-19 pandemic. In order to evaluate the potential role played by this setting in the risk of contracting legionellosis, we conducted a cross-sectional study to evaluate the presence of Legionella spp. in some Italian thermal facilities. Specifically, we retrospectively analyzed the results of a 16-year surveillance carried out before the COVID-19 pandemic. Of 409 samples, 70 (17.1%) were positive with Legionella spp. but there was an overall decrease over time. L. pneumophila 2–14 were by far the most common detected serotypes, while L. pneumophila 1 accounted for only 8.8%. Of all the different kind of samples, swabs and municipal water samples were the most contaminated. Moreover, in the positive samples, bacterial load was often at intermediate values. In only a small percentage of samples was load high and, in this case, L. pneumophila 1 was often the most common strain. Our results show the importance of a continuous monitoring of Legionella risk in these settings, even more so now after the COVID-19 pandemic and the prolonged break in activities. Water is the natural environment of Legionella spp. and environment in general plays a crucial role in the transmission of these bacteria; therefore, it would be useful to frame this infection in a “One Health” key.
- Open Access
- 28 March 2019
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 16 (7) , 1103
Environmental Surveillance of Legionellosis within an Italian University Hospital—Results of 15 Years of Analysis
Legionnaires’ disease is normally acquired by inhalation of legionellae from a contaminated environmental source. Water systems of large and old buildings, such as hospitals, can be contaminated with legionellae and therefore represent a potential risk for the hospital population. In this study, we demonstrated the constant presence of Legionella in water samples from the water system of a large university hospital in Messina (Sicily, Italy) consisting of 11 separate pavilions during a period of 15 years (2004–2018). In total, 1346 hot water samples were collected between January 2004 and December 2018. During this period, to recover Legionella spp. from water samples, the standard procedures reported by the 2000 Italian Guidelines were adopted; from May 2015 to 2018 Italian Guidelines revised in 2015 (ISS, 2015) were used. Most water samples (72%) were positive to L. pneumophila serogroups 2–14, whereas L. pneumophila serogroup 1 accounted for 18% and non-Legionella pneumophila spp. Accounted for 15%. Most of the positive samples were found in the buildings where the following critical wards are situated: (Intensive Care Unit) ICU, Neurosurgery, Surgeries, Pneumology, and Neonatal Intensive Unit Care. This study highlights the importance of the continuous monitoring of hospital water samples to prevent the potential risk of nosocomial legionellosis.
- 28 March 2019
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 16 (7) , 1103
Open AccessEnvironmental Surveillance of Legionellosis within an Italian University Hospital—Results of 15 Years of Analysis
Legionnaires’ disease is normally acquired by inhalation of legionellae from a contaminated environmental source. Water systems of large and old buildings, such as hospitals, can be contaminated with legionellae and therefore represent a potential risk for the hospital population. In this study, we demonstrated the constant presence of Legionella in water samples from the water system of a large university hospital in Messina (Sicily, Italy) consisting of 11 separate pavilions during a period of 15 years (2004–2018). In total, 1346 hot water samples were collected between January 2004 and December 2018. During this period, to recover Legionella spp. from water samples, the standard procedures reported by the 2000 Italian Guidelines were adopted; from May 2015 to 2018 Italian Guidelines revised in 2015 (ISS, 2015) were used. Most water samples (72%) were positive to L. pneumophila serogroups 2–14, whereas L. pneumophila serogroup 1 accounted for 18% and non-Legionella pneumophila spp. Accounted for 15%. Most of the positive samples were found in the buildings where the following critical wards are situated: (Intensive Care Unit) ICU, Neurosurgery, Surgeries, Pneumology, and Neonatal Intensive Unit Care. This study highlights the importance of the continuous monitoring of hospital water samples to prevent the potential risk of nosocomial legionellosis.
- 1 September 2017
- Vol. 168 (5) , E338-E339
Because legionella is one of the most fearsome ICAs
La Legionellosi è una polmonite che può presentare un decorso variabile a seconda se i soggetti colpiti risiedono nel loro domicilio, sono ospiti di strutture recettive o sono ospedalizzati. In ambito ospedaliero, che annovera questa patologia tra le più pericolose Infezioni Correlate all'Assistenza (ICA), si registrano decisamente i casi più gravi e assai spesso letali. Gli errori nella Valutazione del Rischio e negli interventi di risanamento contribuiscono alla proliferazione all'interno delle condutture idriche di un temibile microrganismo che può essere eliminato o ridotto solo con un approccio multidisciplinare.
- 1 September 2017
- Vol. 168 (5) , E338-E339
Because legionella is one of the most fearsome ICAs
La Legionellosi è una polmonite che può presentare un decorso variabile a seconda se i soggetti colpiti risiedono nel loro domicilio, sono ospiti di strutture recettive o sono ospedalizzati. In ambito ospedaliero, che annovera questa patologia tra le più pericolose Infezioni Correlate all'Assistenza (ICA), si registrano decisamente i casi più gravi e assai spesso letali. Gli errori nella Valutazione del Rischio e negli interventi di risanamento contribuiscono alla proliferazione all'interno delle condutture idriche di un temibile microrganismo che può essere eliminato o ridotto solo con un approccio multidisciplinare.
- Open Access
- 22 June 2017
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 14 (7) , 670
Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study
Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis®μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis®μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis®μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis®μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.
- 22 June 2017
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 14 (7) , 670
Open AccessEvaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study
Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis®μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis®μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis®μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis®μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.
- 30 June 2015
- Published by Springer Nature
- p. 79-101
Microbial Toxins in Foods: The Importance of Escherichia coli, a Versatile Enemy
- 30 June 2015
- Published by Springer Nature
- p. 79-101
Microbial Toxins in Foods: The Importance of Escherichia coli, a Versatile Enemy
- 30 June 2015
- Published by Springer Nature
- p. 13-55
Biological Toxins from Marine and Freshwater Microalgae
- 30 June 2015
- Published by Springer Nature
- p. 13-55
Biological Toxins from Marine and Freshwater Microalgae
- 12 March 2015
- Vol. 38, 62-5
[Legionella spp. contamination in indoor air: preliminary results of an Italian multicenter study].
To propose a standardized protocol for the evaluation of Legionella contamination in air. A bathroom having a Legionella contamination in water >1,000 cfu/l was selected in 10 different healthcare facilities. Air contamination was assessed by active (Surface Air System, SAS) and passive (Index of Microbial Air, IMA) sampling for 8 hours, about 1 m away from the floor and 50 cm from the tap water. Two hundred liters of air were sampled by SAS every 12 min, after flushing water for 2 min. The IMA value was calculated as the mean value of colony forming units/16 plates exposed during sampling (2 plates/hour). Water contamination was evaluated at T0, after 4 and 8 hours, according to the standard methods. Air contamination by Legionella was found in three healthcare facilities (one with active and two with passive sampling), showing a concomitant tap water contamination (median=40,000; range 1,100-43,000 cfu/l). The remaining seven hospitals isolated Legionella spp. exclusively from water samples (median=8,000; range 1,200-70,000 cfu/l). Our data suggest that environmental Legionella contamination cannot be assessed only through the air sampling, even in the presence of an important water contamination.
- 12 March 2015
- Vol. 38, 62-5
[Legionella spp. contamination in indoor air: preliminary results of an Italian multicenter study].
To propose a standardized protocol for the evaluation of Legionella contamination in air. A bathroom having a Legionella contamination in water >1,000 cfu/l was selected in 10 different healthcare facilities. Air contamination was assessed by active (Surface Air System, SAS) and passive (Index of Microbial Air, IMA) sampling for 8 hours, about 1 m away from the floor and 50 cm from the tap water. Two hundred liters of air were sampled by SAS every 12 min, after flushing water for 2 min. The IMA value was calculated as the mean value of colony forming units/16 plates exposed during sampling (2 plates/hour). Water contamination was evaluated at T0, after 4 and 8 hours, according to the standard methods. Air contamination by Legionella was found in three healthcare facilities (one with active and two with passive sampling), showing a concomitant tap water contamination (median=40,000; range 1,100-43,000 cfu/l). The remaining seven hospitals isolated Legionella spp. exclusively from water samples (median=8,000; range 1,200-70,000 cfu/l). Our data suggest that environmental Legionella contamination cannot be assessed only through the air sampling, even in the presence of an important water contamination.