Aggelos Zacharopoulos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aggelos Zacharopoulos has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Jayanta Deb Mondol
Ulster University
3 shared publications - Adrian Pugsley
Belfast School of Architecture and the Built Environment, CST, Ulster University, Coleraine, Northern Ireland, UK
2 shared publications - Mervyn Smyth
University of Ulster
2 shared publications - Caterina Brandoni
Centre for Sustainable Technologies, School of Architecture and the Built Environment, Ulster University, Belfast BT15 1ED, UK
1 shared publication - Corentin Jankowiak
Centre for Sustainable Technologies (CST), University of Ulster, Shore Rd, Newtownabbey BT37 0ZQ, UK
1 shared publication - Dan Nchelatebe Nkwetta
Sustainable Building Envelope Centre, Corus Colors; Tata Steel, Shotton Works; Flintshire; Northern Wales; UK
1 shared publication
Latest Publications
- Open Access
Experimental Characterization of the Optical Performance of Concentrating Photovoltaic Glazing (CoPVG) Systems
An experiment was conducted to test the optical efficiency of the lenses of the Concentrating Photovoltaic Glazing (CoPVG) concept. The CoPVG is a seasonal glazing system consisting of longitudinal prismatic lenses. The lenses concentrate sunlight onto the focus where Photovoltaic (PV) cells are bonded, generating electricity while simultaneously preventing excessive glare indoors during summer. The system transmits sunlight for daylight purposes in winter. The experimental results were compared with an analytical model developed at Ulster University. Although there were discrepancies between the model and the experimental results, the model can still predict the optical performance of the lenses reliably, and can therefore still provide an overview of the concept’s optical performance. The model was then used to create a visual representation of the glazing’s annual optical performance, demonstrating how the glazing responds to changes in the sun’s position in the sky throughout the year. This analysis allows for balancing the need for natural lighting and energy generation, and so enables designers to evaluate annual optical performance of the CoPVG lens quickly and accurately. A case study of a building in Belfast is presented to demonstrate the application of the model. As an example, the results indicate that utilizing the lenses in glazing towards the south leads to a shift in its performance from room lighting to shading on 1st April, and vice versa on 15 September. The analyses also show that utilizing the CoPVG lenses can potentially enhance the electrical output power of the glazing ranging between 5% and 8% and from 46% up to 52% during winter and summer, respectively, compared with traditional Semi-Transparent Photovoltaic (STPV) glazing with the same opaque area percentage.
Open AccessExperimental Characterization of the Optical Performance of Concentrating Photovoltaic Glazing (CoPVG) Systems
An experiment was conducted to test the optical efficiency of the lenses of the Concentrating Photovoltaic Glazing (CoPVG) concept. The CoPVG is a seasonal glazing system consisting of longitudinal prismatic lenses. The lenses concentrate sunlight onto the focus where Photovoltaic (PV) cells are bonded, generating electricity while simultaneously preventing excessive glare indoors during summer. The system transmits sunlight for daylight purposes in winter. The experimental results were compared with an analytical model developed at Ulster University. Although there were discrepancies between the model and the experimental results, the model can still predict the optical performance of the lenses reliably, and can therefore still provide an overview of the concept’s optical performance. The model was then used to create a visual representation of the glazing’s annual optical performance, demonstrating how the glazing responds to changes in the sun’s position in the sky throughout the year. This analysis allows for balancing the need for natural lighting and energy generation, and so enables designers to evaluate annual optical performance of the CoPVG lens quickly and accurately. A case study of a building in Belfast is presented to demonstrate the application of the model. As an example, the results indicate that utilizing the lenses in glazing towards the south leads to a shift in its performance from room lighting to shading on 1st April, and vice versa on 15 September. The analyses also show that utilizing the CoPVG lenses can potentially enhance the electrical output power of the glazing ranging between 5% and 8% and from 46% up to 52% during winter and summer, respectively, compared with traditional Semi-Transparent Photovoltaic (STPV) glazing with the same opaque area percentage.
- 1 March 2020
- Published by Elsevier in Solar Energy
- Vol. 198, 36-52
Simulation and experimental validation of solar radiation distribution on the absorber of a line-axis asymmetric compound parabolic concentrator
- 1 March 2020
- Published by Elsevier in Solar Energy
- Vol. 198, 36-52
Simulation and experimental validation of solar radiation distribution on the absorber of a line-axis asymmetric compound parabolic concentrator
- Open Access
The Role of Domestic Integrated Battery Energy Storage Systems for Electricity Network Performance Enhancement
Low carbon technologies are necessary to address global warming issues through electricity decabonisation, but their large-scale integration challenges the stability and security of electricity supply. Energy storage can support this transition by bringing flexibility to the grid but since it represents high capital investments, the right choices must be made in terms of the technology and the location point in the network. Most of the potential for storage is achieved when connected further from the load, and Battery Energy Storage Systems (BESS) are a strong candidate for behind-the-meter integration. This work reviews and evaluates the state-of-the-art development of BESS, analysing the benefits and barriers to a wider range of applications in the domestic sector. Existing modelling tools that are key for a better assessment of the impacts of BESS to the grid are also reviewed. It is shown that the technology exists and has potential for including Electric Vehicle battery reuse, however it is still mostly applied to optimise domestic photovoltaic electricity utilisation. The barriers to a wider integration are financial, economic, technical, as well as market and regulation. Increased field trials and robust numerical modelling should be the next step to gain investment confidence and allow BESS to reach their potential.
Open AccessThe Role of Domestic Integrated Battery Energy Storage Systems for Electricity Network Performance Enhancement
Low carbon technologies are necessary to address global warming issues through electricity decabonisation, but their large-scale integration challenges the stability and security of electricity supply. Energy storage can support this transition by bringing flexibility to the grid but since it represents high capital investments, the right choices must be made in terms of the technology and the location point in the network. Most of the potential for storage is achieved when connected further from the load, and Battery Energy Storage Systems (BESS) are a strong candidate for behind-the-meter integration. This work reviews and evaluates the state-of-the-art development of BESS, analysing the benefits and barriers to a wider range of applications in the domestic sector. Existing modelling tools that are key for a better assessment of the impacts of BESS to the grid are also reviewed. It is shown that the technology exists and has potential for including Electric Vehicle battery reuse, however it is still mostly applied to optimise domestic photovoltaic electricity utilisation. The barriers to a wider integration are financial, economic, technical, as well as market and regulation. Increased field trials and robust numerical modelling should be the next step to gain investment confidence and allow BESS to reach their potential.
- 5 August 2015
- Published by Springer Nature
- p. 353-376
Building-Integration of High-Concentration Photovoltaic Systems
- 5 August 2015
- Published by Springer Nature
- p. 353-376
Building-Integration of High-Concentration Photovoltaic Systems
- Open Access
- 27 November 2011
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 37 (6) , 570-581
Experimental performance analysis and optimisation of medium temperature solar thermal collectors with silicon oil as a heat transfer fluid
Heat transfer fluids (HTFs) play an essential role in solar water heating systems by transferring collected energy from the collector, perhaps via a heat exchanger to the store. If the store is at a much higher temperature than the fluid, the store acts as a heat source, whereas the fluid acts as a coolant, thus reversing the collection process. This action must be avoided through good controls. Experimental performance analysis and comparison of three different types of solar collectors; a non-concentrating evacuated tube heat pipe and two concentrating single-sided and double-sided coated evacuated tube heat pipes collectors are installed and tested using Dow-corning 550® silicon oil as an HTF under the same operating in-door control conditions, and results are presented in this paper. The performance of these solar collectors was determined from the overall increase in inlet and outlet fluid temperatures, overall fluid temperature differential, energy collection rate, optical efficiencies, and thermal performances. Temperature differential, energy, and collection efficiency diagrams plotted against time were used to represent and compare the solar collectors. Finally, a comparative analysis of these solar collectors using either pressurised water or Dow-corning 550 silicon oil as HTF is presented. Copyright © 2011 John Wiley & Sons, Ltd.
- 27 November 2011
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 37 (6) , 570-581
Open AccessExperimental performance analysis and optimisation of medium temperature solar thermal collectors with silicon oil as a heat transfer fluid
Heat transfer fluids (HTFs) play an essential role in solar water heating systems by transferring collected energy from the collector, perhaps via a heat exchanger to the store. If the store is at a much higher temperature than the fluid, the store acts as a heat source, whereas the fluid acts as a coolant, thus reversing the collection process. This action must be avoided through good controls. Experimental performance analysis and comparison of three different types of solar collectors; a non-concentrating evacuated tube heat pipe and two concentrating single-sided and double-sided coated evacuated tube heat pipes collectors are installed and tested using Dow-corning 550® silicon oil as an HTF under the same operating in-door control conditions, and results are presented in this paper. The performance of these solar collectors was determined from the overall increase in inlet and outlet fluid temperatures, overall fluid temperature differential, energy collection rate, optical efficiencies, and thermal performances. Temperature differential, energy, and collection efficiency diagrams plotted against time were used to represent and compare the solar collectors. Finally, a comparative analysis of these solar collectors using either pressurised water or Dow-corning 550 silicon oil as HTF is presented. Copyright © 2011 John Wiley & Sons, Ltd.
- 1 June 2011
- Published by Elsevier in Renewable Energy
- Vol. 36 (6) , 1766-1779
Experimental characterisation of a novel heat exchanger for a solar hot water application under indoor and outdoor conditions
- 1 June 2011
- Published by Elsevier in Renewable Energy
- Vol. 36 (6) , 1766-1779
Experimental characterisation of a novel heat exchanger for a solar hot water application under indoor and outdoor conditions