Ankit Malhotra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ankit Malhotra has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Gunther Ardelt
Center of Excellence CoSA (Communications—Systems—Applications), Lübeck University of Applied Sciences, 23562 Lübeck, Germany
2 shared publications - Kerstin Lüdtke-Buzug
Universität zu Lübeck
2 shared publications - Steffen Kaufmann
Universität zu Lübeck
2 shared publications - Thorsten M. Buzug
Fraunhofer IMTE, Fraunhofer Research Institution for Individualized Medical Technology and Engineering, Lübeck, Germany
2 shared publications Alexander Neumann
Institute of Medical Engineering, University of Lübeck, Lubeck, Germany
1 shared publicationAndré Behrends
Institute of Medical Engineering, University of Lübeck, Lubeck, Germany
1 shared publication
Latest Publications
- Open Access
- 22 July 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-13
Tracking the Growth of Superparamagnetic Nanoparticles with an In-Situ Magnetic Particle Spectrometer (INSPECT)
Magnetic Particle Spectroscopy (MPS) is a measurement technique to determine the magnetic properties of superparamagnetic iron oxide nanoparticles (SPIONs) in an oscillating magnetic field as applied in Magnetic Particle Imaging (MPI). State of the art MPS devices are solely capable of measuring the magnetization response of the SPIONs to an oscillatory magnetic excitation retrospectively, i.e. after the synthesis process. In this contribution, a novel in-situ magnetic particle spectrometer (INSPECT) is presented, which can be used to monitor the entire synthesis process from particle genesis via growth to the stable colloidal suspension of the nanoparticles in real time. The device is suitable for the use in a biochemistry environment. It has a chamber size of 72 mm such that a 100 ml reaction flask can be used for synthesis. For an alkaline-based precipitation, the change of magnetic properties of SPIONs during the nucleation and growth phase of the synthesis is demonstrated. The device is able to record the changes in the amplitude and phase spectra, and, in turn, the hysteresis. Hence, it is a powerful tool for an in-depth understanding of the nanoparticle formation dynamics during the synthesis process.
- 22 July 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-13
Open AccessTracking the Growth of Superparamagnetic Nanoparticles with an In-Situ Magnetic Particle Spectrometer (INSPECT)
Magnetic Particle Spectroscopy (MPS) is a measurement technique to determine the magnetic properties of superparamagnetic iron oxide nanoparticles (SPIONs) in an oscillating magnetic field as applied in Magnetic Particle Imaging (MPI). State of the art MPS devices are solely capable of measuring the magnetization response of the SPIONs to an oscillatory magnetic excitation retrospectively, i.e. after the synthesis process. In this contribution, a novel in-situ magnetic particle spectrometer (INSPECT) is presented, which can be used to monitor the entire synthesis process from particle genesis via growth to the stable colloidal suspension of the nanoparticles in real time. The device is suitable for the use in a biochemistry environment. It has a chamber size of 72 mm such that a 100 ml reaction flask can be used for synthesis. For an alkaline-based precipitation, the change of magnetic properties of SPIONs during the nucleation and growth phase of the synthesis is demonstrated. The device is able to record the changes in the amplitude and phase spectra, and, in turn, the hysteresis. Hence, it is a powerful tool for an in-depth understanding of the nanoparticle formation dynamics during the synthesis process.
- Open Access
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 599-602
Op-amp based low noise amplifier for magnetic particle spectroscopy
Magnetic particle spectrometry (MPS) is a novel technique used to measure the magnetization response of superparamagnetic iron oxide nanoparticles (SPIONs). Therefore, it is one of the most important tools for the characterization of the SPIONs for imaging modalities such as magnetic particle imaging (MPI) and Magnetic Resonance Imaging (MRI). In MPS, change in the particle magnetization induces a voltage in a dedicated receive coil. The amplitude of the signal can be very low (ranging from a few nV to 100 μV) depending upon the concentration of the nanoparticles. Hence, the received signal needs to be amplified with a low noise amplifier (LNA). LNA’s paramount task is to amplify the received signal while keeping the noise induced by its own circuitry minimum. In the current research, we purpose modeling, design, and development of a prototyped LNA for MPS. The designed prototype LNA is based on the parallelization technique of Op-amps. The prototyped LNA consists of 16 Op-amps in parallel and is manufactured on a printed circuit board (PCB), with a size of 110.38 mm × 59.46 mm and 234 components. The input noise of the amplifier is approx. 546 pV/√Hz with a noise figure (NF) of approx. 1.4 dB with a receive coil termination. Furthermore, a comparison between the prototyped LNA and a commercially available amplifier is shown.
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 599-602
Open AccessOp-amp based low noise amplifier for magnetic particle spectroscopy
Magnetic particle spectrometry (MPS) is a novel technique used to measure the magnetization response of superparamagnetic iron oxide nanoparticles (SPIONs). Therefore, it is one of the most important tools for the characterization of the SPIONs for imaging modalities such as magnetic particle imaging (MPI) and Magnetic Resonance Imaging (MRI). In MPS, change in the particle magnetization induces a voltage in a dedicated receive coil. The amplitude of the signal can be very low (ranging from a few nV to 100 μV) depending upon the concentration of the nanoparticles. Hence, the received signal needs to be amplified with a low noise amplifier (LNA). LNA’s paramount task is to amplify the received signal while keeping the noise induced by its own circuitry minimum. In the current research, we purpose modeling, design, and development of a prototyped LNA for MPS. The designed prototype LNA is based on the parallelization technique of Op-amps. The prototyped LNA consists of 16 Op-amps in parallel and is manufactured on a printed circuit board (PCB), with a size of 110.38 mm × 59.46 mm and 234 components. The input noise of the amplifier is approx. 546 pV/√Hz with a noise figure (NF) of approx. 1.4 dB with a receive coil termination. Furthermore, a comparison between the prototyped LNA and a commercially available amplifier is shown.
- Open Access
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 529-532
Effect of key parameters on synthesis of superparamagnetic nanoparticles (SPIONs)
There are various methods to synthesize superparamagnetic nanoparticles (SPIONs) useful for MPI (magnetic particle imaging) and in therapy (Hypothermia) such as co-precipitation, hydrothermal reactions etc. In this research, the focus is to analyse the effects of crucial parameters such as effect of molecular mass of dextran and temperature of the co-precipitation. These parameters play a crucial role in the inherent magnetic properties of the resulting SPIONs. The amplitude spectrum and hysteresis curve of the SPIONs is analysed with MPS (magnetic particle spectrometer). PCCS (photon cross-correlation spectroscopy) measurements are done to analyse the size distribution of hydrodynamic diameter the resulting SPIONs.
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 529-532
Open AccessEffect of key parameters on synthesis of superparamagnetic nanoparticles (SPIONs)
There are various methods to synthesize superparamagnetic nanoparticles (SPIONs) useful for MPI (magnetic particle imaging) and in therapy (Hypothermia) such as co-precipitation, hydrothermal reactions etc. In this research, the focus is to analyse the effects of crucial parameters such as effect of molecular mass of dextran and temperature of the co-precipitation. These parameters play a crucial role in the inherent magnetic properties of the resulting SPIONs. The amplitude spectrum and hysteresis curve of the SPIONs is analysed with MPS (magnetic particle spectrometer). PCCS (photon cross-correlation spectroscopy) measurements are done to analyse the size distribution of hydrodynamic diameter the resulting SPIONs.
- Open Access
- 29 July 2015
- Published by MDPI AG in Electronics
- Vol. 4 (3) , 507-525
A FPGA-Based Broadband EIT System for Complex Bioimpedance Measurements—Design and Performance Estimation
Electrical impedance tomography (EIT) is an imaging method that is able to estimate the electrical conductivity distribution of living tissue. This work presents a field programmable gate array (FPGA)-based multi-frequency EIT system for complex, time-resolved bioimpedance measurements. The system has the capability to work with measurement setups with up to 16 current electrodes and 16 voltage electrodes. The excitation current has a range of about 10 µA to 5 mA, whereas the sinusoidal signal used for excitation can have a frequency of up to 500 kHz. Additionally, the usage of a chirp or rectangular signal excitation is possible. Furthermore, the described system has a sample rate of up to 3480 impedance spectra per second (ISPS). The performance of the EIT system is demonstrated with a resistor-based phantom and tank phantoms. Additionally, first measurements taken from the human thorax during a breathing cycle are presented.
- 29 July 2015
- Published by MDPI AG in Electronics
- Vol. 4 (3) , 507-525
Open AccessA FPGA-Based Broadband EIT System for Complex Bioimpedance Measurements—Design and Performance Estimation
Electrical impedance tomography (EIT) is an imaging method that is able to estimate the electrical conductivity distribution of living tissue. This work presents a field programmable gate array (FPGA)-based multi-frequency EIT system for complex, time-resolved bioimpedance measurements. The system has the capability to work with measurement setups with up to 16 current electrodes and 16 voltage electrodes. The excitation current has a range of about 10 µA to 5 mA, whereas the sinusoidal signal used for excitation can have a frequency of up to 500 kHz. Additionally, the usage of a chirp or rectangular signal excitation is possible. Furthermore, the described system has a sample rate of up to 3480 impedance spectra per second (ISPS). The performance of the EIT system is demonstrated with a resistor-based phantom and tank phantoms. Additionally, first measurements taken from the human thorax during a breathing cycle are presented.
- 7 January 2013
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
In-Ear Pulse Wave Measurements: A Pilot Study
- 7 January 2013
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
In-Ear Pulse Wave Measurements: A Pilot Study