Jeffrey S. A. Stringer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jeffrey S. A. Stringer has a total of 504 co-authors. Here are the top co-authors by number of shared publications:
Bellington Vwalika
Division of Global Women's Health, Department of Obstetrics and Gynecology, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
16 shared publications- Joan T. Price
Department of Obstetrics and Gynecology, University of North Carolina School of Medicine, Chapel Hill, North Carolina, 27599, USA
14 shared publications - Benjamin H. Chi
Affiliation Department of Obstetrics and Gynecology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, United States of America
12 shared publications - Margaret Phiri Kasaro
UNC Global Projects Zambia, Lusaka, Zambia
12 shared publications - Bethany L. Freeman
Department of Obstetrics and Gynecology, University of North Carolina School of Medicine, Chapel Hill, North Carolina, 27599, USA
10 shared publications - Bellington Vwalika
University of Zambia, School of Medicine, Lusaka, Zambia
9 shared publications
Latest Publications
- Open Access
Sphingosine-1-Phosphate Receptor and Kinase Expression in the Reproductive Tract Is Associated with HIV Infection and Preterm Birth in a Cohort of Pregnant Women in Zambia
Women living with HIV face an increased burden of spontaneous preterm birth (sPTB); however, the underlying immunological mechanisms of sPTB and its association with HIV infection are poorly understood. Although the limited earlier literature implicates sphingosine-1-phosphate (S1P), a lysosphingolipid signaling molecule, in reproductive biology, the association of S1P signaling with HIV and sPTB has not been investigated. We examined whether two S1P signaling components, S1P receptors and sphingosine kinases, are expressed in the female reproductive tract and whether levels are associated with HIV status or spontaneous preterm birth. We quantified the mRNA expression of sphingosine-1-phosphate receptors 1 and 3 (S1PR1/S1PR3) and sphingosine kinases 1 and 2 (SPHK1/SPHK2) in 167 banked vaginal swab specimens collected between 14 and 26 weeks of gestation in a longitudinal pregnancy cohort in Lusaka, Zambia. We evaluated the expression of S1PR1, S1PR3, SPHK1, and SPHK2 by real-time quantitative reverse transcription PCR (RT-qPCR) in four groups (n = 41–42 each): women without HIV (WWoH) with term birth (≥37 weeks of gestation; TB), WWoH with spontaneous preterm birth (SPHK1 and SPHK2 mRNA expression were generally comparable among women independent of HIV status or birth outcome, though SPHK2 trended toward higher expression in women with HIV and women with sPTB. In contrast, S1PR1 mRNA trended toward higher expression in WWH vs. WWoH overall, as well as in WWH vs. WWoH among women with sPTB. Similarly, S1PR3 mRNA expression was greater in women with HIV than in women without HIV, and WWH, both with TB and sPTB, had higher S1PR3 mRNA expression than WWoH with TB. Perturbations in S1PR1 and S1PR3 mRNA expression may be associated with inflammation related to HIV infection and spontaneous preterm birth, suggesting that further studies of S1P signaling in pregnancy, especially among women with HIV, are warranted.
Open AccessSphingosine-1-Phosphate Receptor and Kinase Expression in the Reproductive Tract Is Associated with HIV Infection and Preterm Birth in a Cohort of Pregnant Women in Zambia
Women living with HIV face an increased burden of spontaneous preterm birth (sPTB); however, the underlying immunological mechanisms of sPTB and its association with HIV infection are poorly understood. Although the limited earlier literature implicates sphingosine-1-phosphate (S1P), a lysosphingolipid signaling molecule, in reproductive biology, the association of S1P signaling with HIV and sPTB has not been investigated. We examined whether two S1P signaling components, S1P receptors and sphingosine kinases, are expressed in the female reproductive tract and whether levels are associated with HIV status or spontaneous preterm birth. We quantified the mRNA expression of sphingosine-1-phosphate receptors 1 and 3 (S1PR1/S1PR3) and sphingosine kinases 1 and 2 (SPHK1/SPHK2) in 167 banked vaginal swab specimens collected between 14 and 26 weeks of gestation in a longitudinal pregnancy cohort in Lusaka, Zambia. We evaluated the expression of S1PR1, S1PR3, SPHK1, and SPHK2 by real-time quantitative reverse transcription PCR (RT-qPCR) in four groups (n = 41–42 each): women without HIV (WWoH) with term birth (≥37 weeks of gestation; TB), WWoH with spontaneous preterm birth (SPHK1 and SPHK2 mRNA expression were generally comparable among women independent of HIV status or birth outcome, though SPHK2 trended toward higher expression in women with HIV and women with sPTB. In contrast, S1PR1 mRNA trended toward higher expression in WWH vs. WWoH overall, as well as in WWH vs. WWoH among women with sPTB. Similarly, S1PR3 mRNA expression was greater in women with HIV than in women without HIV, and WWH, both with TB and sPTB, had higher S1PR3 mRNA expression than WWoH with TB. Perturbations in S1PR1 and S1PR3 mRNA expression may be associated with inflammation related to HIV infection and spontaneous preterm birth, suggesting that further studies of S1P signaling in pregnancy, especially among women with HIV, are warranted.
- Open Access
- 3 April 2026
- Published by International Society of Global Health in Journal of Global Health
- Vol. 16, 05002
Multi-Omics for Mothers and Infants (MOMI) Consortium: a global initiative to study adverse pregnancy outcomes
Pregnancy complications such as preeclampsia (PE) and adverse pregnancy outcomes (APOs) such as preterm birth (PTB), small for gestational age (SGA), and stillbirth (SB) pose a serious global health challenge and collectively contribute to high rates of maternal and infant mortality and morbidity. Close to 2 million stillbirths were reported in 2020 [1,2] while […]
- 3 April 2026
- Published by International Society of Global Health in Journal of Global Health
- Vol. 16, 05002
Open AccessMulti-Omics for Mothers and Infants (MOMI) Consortium: a global initiative to study adverse pregnancy outcomes
Pregnancy complications such as preeclampsia (PE) and adverse pregnancy outcomes (APOs) such as preterm birth (PTB), small for gestational age (SGA), and stillbirth (SB) pose a serious global health challenge and collectively contribute to high rates of maternal and infant mortality and morbidity. Close to 2 million stillbirths were reported in 2020 [1,2] while […]
- Open Access
Assessment of Maternal Hematological Parameters and Kidney and Liver Injury Markers Across Adverse Pregnancy Outcomes: A Cross Sectional Study
Adverse pregnancy outcomes (APOs) such as prematurity, low birth weight, stillbirth, and birth defects remain significant global health challenges. While many risk factors are known, APOs encompass a wide range of outcomes with diverse, sometimes poorly understood etiologies. Pregnancy-related acute kidney injury (PR-AKI) and liver injury are particularly associated with increased maternal and fetal mortality. This study investigated the association between hematological parameters, kidney and liver injury markers and adverse pregnancy outcomes. This cross-sectional study involved 714 pregnant women aged 18–40 years, conducted between August 2021 and August 2022. Maternal blood samples were collected before and after delivery to compare hematological parameters. Kidney and liver injury markers were measured using standard methods. The study analysed the association of these parameters with adverse pregnancy outcomes. The median age of participants was 24 years (Q1, Q3: 21, 26). Women with adverse pregnancy outcomes had statistically significant serum creatinine levels [0.52 mg/dL (0.45, 0.58)] compared to those without [0.50 mg/dL (0.44, 0.56)], although the difference was not clinically significant. Elevated Aspartate Transaminase (AST) levels (>90th percentile) were statistically associated with adverse pregnancy outcomes. Pairwise comparisons with Bonferroni corrections revealed significant differences in Hemoglobin (Hb), White Blood Cell (WBC), Red Blood Cell (RBC), platelet, and Packed Cell Volume (PCV) levels before and after delivery (p < 0.05) in both groups. Elevated AST levels, but not other hematological or biochemical parameters, were independently associated with adverse pregnancy outcomes, whereas creatinine differences lacked clinical impact.
Open AccessAssessment of Maternal Hematological Parameters and Kidney and Liver Injury Markers Across Adverse Pregnancy Outcomes: A Cross Sectional Study
Adverse pregnancy outcomes (APOs) such as prematurity, low birth weight, stillbirth, and birth defects remain significant global health challenges. While many risk factors are known, APOs encompass a wide range of outcomes with diverse, sometimes poorly understood etiologies. Pregnancy-related acute kidney injury (PR-AKI) and liver injury are particularly associated with increased maternal and fetal mortality. This study investigated the association between hematological parameters, kidney and liver injury markers and adverse pregnancy outcomes. This cross-sectional study involved 714 pregnant women aged 18–40 years, conducted between August 2021 and August 2022. Maternal blood samples were collected before and after delivery to compare hematological parameters. Kidney and liver injury markers were measured using standard methods. The study analysed the association of these parameters with adverse pregnancy outcomes. The median age of participants was 24 years (Q1, Q3: 21, 26). Women with adverse pregnancy outcomes had statistically significant serum creatinine levels [0.52 mg/dL (0.45, 0.58)] compared to those without [0.50 mg/dL (0.44, 0.56)], although the difference was not clinically significant. Elevated Aspartate Transaminase (AST) levels (>90th percentile) were statistically associated with adverse pregnancy outcomes. Pairwise comparisons with Bonferroni corrections revealed significant differences in Hemoglobin (Hb), White Blood Cell (WBC), Red Blood Cell (RBC), platelet, and Packed Cell Volume (PCV) levels before and after delivery (p < 0.05) in both groups. Elevated AST levels, but not other hematological or biochemical parameters, were independently associated with adverse pregnancy outcomes, whereas creatinine differences lacked clinical impact.
- Open Access
- 30 October 2025
- Published by MDPI AG in Preprints.org
Assessment of Maternal Hematological Parameters, Kidney and Liver Injury Markers across Adverse Pregnancy Outcomes: A Cross Sectional Study
Background and Aim: Adverse pregnancy outcomes (APOs) such as prematurity, low birth weight, stillbirth, and birth defects remain significant global health challenges. While many risk factors are known, APOs encompass a wide range of outcomes with di-verse, sometimes poorly understood etiologies. Pregnancy-related acute kidney injury (PR-AKI) and liver injury are particularly associated with increased maternal and fetal mortality. This study investigated the association between hematological parameters, kidney and liver injury markers and adverse pregnancy outcomes. Materials and Meth-ods: This cross-sectional study involved 714 pregnant women aged 18-40 years, conduct-ed between August 2021 and August 2022. Maternal blood samples were collected before and after delivery to compare hematological parameters. Kidney and liver injury markers were measured using standard methods. The study analysed the association of these pa-rameters with adverse pregnancy outcomes. Results: The median age of participants was 24 years (Q1, Q3: 21, 26). Women with adverse pregnancy outcomes had statistically sig-nificant serum creatinine levels [0.52 mg/dL (0.45, 0.58)] compared to those without [0.50 mg/dL (0.44, 0.56)], although the difference was not clinically significant. Elevated AST levels (>90th percentile) were statistically associated with adverse pregnancy outcomes. Pairwise comparisons with Bonferroni corrections revealed significant differences in Hb, WBC, RBC, platelet, and PCV levels before and after delivery (p< 0.05) in both groups. Con-clusion: The study revealed a statistically significant yet clinically negligible difference in creatinine levels between women with and without adverse pregnancy outcomes. Elevat-ed AST levels showed an associated with APOs, whereas other biochemical markers showed no association.
- 30 October 2025
- Published by MDPI AG in Preprints.org
Open AccessAssessment of Maternal Hematological Parameters, Kidney and Liver Injury Markers across Adverse Pregnancy Outcomes: A Cross Sectional Study
Background and Aim: Adverse pregnancy outcomes (APOs) such as prematurity, low birth weight, stillbirth, and birth defects remain significant global health challenges. While many risk factors are known, APOs encompass a wide range of outcomes with di-verse, sometimes poorly understood etiologies. Pregnancy-related acute kidney injury (PR-AKI) and liver injury are particularly associated with increased maternal and fetal mortality. This study investigated the association between hematological parameters, kidney and liver injury markers and adverse pregnancy outcomes. Materials and Meth-ods: This cross-sectional study involved 714 pregnant women aged 18-40 years, conduct-ed between August 2021 and August 2022. Maternal blood samples were collected before and after delivery to compare hematological parameters. Kidney and liver injury markers were measured using standard methods. The study analysed the association of these pa-rameters with adverse pregnancy outcomes. Results: The median age of participants was 24 years (Q1, Q3: 21, 26). Women with adverse pregnancy outcomes had statistically sig-nificant serum creatinine levels [0.52 mg/dL (0.45, 0.58)] compared to those without [0.50 mg/dL (0.44, 0.56)], although the difference was not clinically significant. Elevated AST levels (>90th percentile) were statistically associated with adverse pregnancy outcomes. Pairwise comparisons with Bonferroni corrections revealed significant differences in Hb, WBC, RBC, platelet, and PCV levels before and after delivery (p< 0.05) in both groups. Con-clusion: The study revealed a statistically significant yet clinically negligible difference in creatinine levels between women with and without adverse pregnancy outcomes. Elevat-ed AST levels showed an associated with APOs, whereas other biochemical markers showed no association.
- Open Access
- 29 July 2025
- Published by MDPI AG in Preprints.org
Assessment of Maternal Hematological Parameters, Kidney and Liver Injury Markers Across Adverse Pregnancy Outcomes: A Cross Sectional Study
Background/Objectives: Adverse pregnancy outcomes (APOs) such as prematurity, low birth weight, stillbirth, and birth defects remain significant global health challenges. While many risk factors are known, APOs encompass a wide range of outcomes with diverse, sometimes poorly understood etiologies. Pregnancy-related acute kidney injury (PR-AKI) and liver injury are particularly associated with increased maternal and fetal mortality. This study investigated the association between hematological parameters, kidney and liver injury markers and adverse pregnancy outcomes. Methods: This cross-sectional study involved 714 pregnant women aged 18-40 years, conducted between March 2021 and August 2022. Maternal blood samples were collected before and after delivery to compare hematological parameters. Kidney and liver injury markers were measured using standard methods. The study analyzed the association of these parameters with adverse pregnancy outcomes. Results: The median age of participants was 24 years (Q1, Q3: 21, 26). Women with adverse pregnancy outcomes had statistically significant serum creatinine levels [0.52 mg/dL (0.45, 0.58)] compared to those without [0.50 mg/dL (0.44, 0.56)], although the difference was not clinically significant. Elevated AST levels (>90th percentile) were statistically associated with adverse pregnancy outcomes. Pairwise comparisons with Bonferroni corrections revealed significant differences in Hb, WBC, RBC, platelet, and PCV levels before and after delivery (p<0.05) in both groups. Conclusions: This study highlights a small but significant association of elevated serum creatinine and AST levels with adverse pregnancy outcomes, suggesting their potential role as accessible biomarkers for early risk identification in clinical settings.
- 29 July 2025
- Published by MDPI AG in Preprints.org
Open AccessAssessment of Maternal Hematological Parameters, Kidney and Liver Injury Markers Across Adverse Pregnancy Outcomes: A Cross Sectional Study
Background/Objectives: Adverse pregnancy outcomes (APOs) such as prematurity, low birth weight, stillbirth, and birth defects remain significant global health challenges. While many risk factors are known, APOs encompass a wide range of outcomes with diverse, sometimes poorly understood etiologies. Pregnancy-related acute kidney injury (PR-AKI) and liver injury are particularly associated with increased maternal and fetal mortality. This study investigated the association between hematological parameters, kidney and liver injury markers and adverse pregnancy outcomes. Methods: This cross-sectional study involved 714 pregnant women aged 18-40 years, conducted between March 2021 and August 2022. Maternal blood samples were collected before and after delivery to compare hematological parameters. Kidney and liver injury markers were measured using standard methods. The study analyzed the association of these parameters with adverse pregnancy outcomes. Results: The median age of participants was 24 years (Q1, Q3: 21, 26). Women with adverse pregnancy outcomes had statistically significant serum creatinine levels [0.52 mg/dL (0.45, 0.58)] compared to those without [0.50 mg/dL (0.44, 0.56)], although the difference was not clinically significant. Elevated AST levels (>90th percentile) were statistically associated with adverse pregnancy outcomes. Pairwise comparisons with Bonferroni corrections revealed significant differences in Hb, WBC, RBC, platelet, and PCV levels before and after delivery (p<0.05) in both groups. Conclusions: This study highlights a small but significant association of elevated serum creatinine and AST levels with adverse pregnancy outcomes, suggesting their potential role as accessible biomarkers for early risk identification in clinical settings.
- Open Access
- 4 February 2025
- Published by BMJ in BMJ Public Health
- Vol. 3 (1) , e000900
Association between gestational weight gain and adverse pregnancy outcomes: cohort analysis from South Asia and Sub-Saharan Africa
Introduction: Studies of gestational weight gain (GWG) and adverse pregnancy outcomes seldom focus on low-to-middle-income countries (LMICs), despite their high burden of morbidity and mortality. We examined GWG patterns and adverse pregnancy outcomes in a consortium of pregnancy cohorts from LMICs. Methods: We analysed data from five observational pregnancy cohorts in Bangladesh (two cohorts), India, Pakistan and Zambia. The study population comprised 15 286 singleton pregnancies with two or more maternal antenatal weight measurements. We estimated reference values for GWG using longitudinal models and calculated weight gain for gestational age Z-scores. We then estimated the associated risks of preterm birth, low birth weight, and small for gestational age, stratified by maternal body mass index (BMI), using marginal generalised linear models and plotted non-linear trends in the associations. Results: The median baseline maternal and gestational age were 24 years (IQR, 21–28) and 13 weeks (IQR 11–16), respectively, with 23% of participants having underweight BMI. The median GWG was 6.8 kg (4.2–9.4) and varied across cohorts from 6.1 kg (3.7–8.5; Bangladesh) to 7.0 kg (4.0–10.0; Zambia). The risk of preterm birth (13%) increased with lower GWG Z-scores among underweight (adjusted risk ratio (ARR), 1.4; 95% CI, 1.1 to 1.9 for lowest Z-score group) and normal BMI participants (ARR, 1.1; 95% CI, 1.0 to 1.2). The risk of low birth weight (25%) increased with lower GWG Z-scores in all BMI strata except obese participants (ARR, 1.7; 95% CI 1.5 to 1.9 among underweight). The risk of small for gestational age (36%) increased with lower GWG Z-scores in all BMI strata (ARR, 1.3; 95% CI 1.2 to 1.4 among underweight). In secondary analyses, alternative measures of GWG (adequacy ratio; INTERGROWTH-21st) had associations that were consistent with those from our study-specific Z-scores, except for a less clear association between preterm birth and INTERGROWTH-21st Z-score. Conclusion: GWG was associated with preterm birth, low birth weight and small for gestational age. Early pregnancy BMI modified the association between GWG and outcomes in the study setting.
- 4 February 2025
- Published by BMJ in BMJ Public Health
- Vol. 3 (1) , e000900
Open AccessAssociation between gestational weight gain and adverse pregnancy outcomes: cohort analysis from South Asia and Sub-Saharan Africa
Introduction: Studies of gestational weight gain (GWG) and adverse pregnancy outcomes seldom focus on low-to-middle-income countries (LMICs), despite their high burden of morbidity and mortality. We examined GWG patterns and adverse pregnancy outcomes in a consortium of pregnancy cohorts from LMICs. Methods: We analysed data from five observational pregnancy cohorts in Bangladesh (two cohorts), India, Pakistan and Zambia. The study population comprised 15 286 singleton pregnancies with two or more maternal antenatal weight measurements. We estimated reference values for GWG using longitudinal models and calculated weight gain for gestational age Z-scores. We then estimated the associated risks of preterm birth, low birth weight, and small for gestational age, stratified by maternal body mass index (BMI), using marginal generalised linear models and plotted non-linear trends in the associations. Results: The median baseline maternal and gestational age were 24 years (IQR, 21–28) and 13 weeks (IQR 11–16), respectively, with 23% of participants having underweight BMI. The median GWG was 6.8 kg (4.2–9.4) and varied across cohorts from 6.1 kg (3.7–8.5; Bangladesh) to 7.0 kg (4.0–10.0; Zambia). The risk of preterm birth (13%) increased with lower GWG Z-scores among underweight (adjusted risk ratio (ARR), 1.4; 95% CI, 1.1 to 1.9 for lowest Z-score group) and normal BMI participants (ARR, 1.1; 95% CI, 1.0 to 1.2). The risk of low birth weight (25%) increased with lower GWG Z-scores in all BMI strata except obese participants (ARR, 1.7; 95% CI 1.5 to 1.9 among underweight). The risk of small for gestational age (36%) increased with lower GWG Z-scores in all BMI strata (ARR, 1.3; 95% CI 1.2 to 1.4 among underweight). In secondary analyses, alternative measures of GWG (adequacy ratio; INTERGROWTH-21st) had associations that were consistent with those from our study-specific Z-scores, except for a less clear association between preterm birth and INTERGROWTH-21st Z-score. Conclusion: GWG was associated with preterm birth, low birth weight and small for gestational age. Early pregnancy BMI modified the association between GWG and outcomes in the study setting.
- Open Access
- 1 December 2024
- Published by Wolters Kluwer Health in JAIDS Journal of Acquired Immune Deficiency Syndromes
- Vol. 97 (4) , 364-370
True and False Positive HIV Point of Care Test Results in a Prospective Multinational Study of At-Risk African Women: Implications for Large-Scale Repeat HIV Testing in HIV Prevention Programs
Background: Accurate HIV point of care testing is the cornerstone of prevention and treatment efforts globally, although false (both negative and positive) results are expected to occur. Setting: We assessed the spectrum of true and false positive HIV results in a large prospective study of HIV incidence in African women using 3 contraceptive methods tested longitudinally in Eswatini, Kenya, South Africa, and Zambia. Methods: HIV serologic testing was conducted quarterly using 2 parallel rapid HIV tests. When one or both tests were positive, additional confirmatory testing was conducted, including HIV enzyme immunoassay (EIA) and RNA. Results: A total of 7730 women contributed 48,234 visits: true positive results occurred at 412 visits (0.9%) and false positives at 96 visits (0.2%). Of 412 women with HIV seroconversion, 10 had discordant (ie, 1 negative and 1 positive) rapid tests and 13 had undetectable HIV RNA levels. Of 62 women with false positive rapid HIV results, most had discordant rapid testing, but 6 (9.7%) had dually positive rapid results, and 4 (6.5%) had false positive or indeterminate EIA results. The positive predictive value of dual positive rapid results was 98.3%. Conclusions: Although most rapid test results were accurate, false positive results were expected and occurred in this population of initially HIV seronegative individuals tested repeatedly and prospectively. When HIV infection occurred, not all cases had textbook laboratory results. Our findings highlight the importance of confirmatory testing, particularly for individuals undergoing repeat testing and in settings where the point prevalence is expected to be low. Trial registration: ClinicalTrials.gov number NCT02550067.
- 1 December 2024
- Published by Wolters Kluwer Health in JAIDS Journal of Acquired Immune Deficiency Syndromes
- Vol. 97 (4) , 364-370
Open AccessTrue and False Positive HIV Point of Care Test Results in a Prospective Multinational Study of At-Risk African Women: Implications for Large-Scale Repeat HIV Testing in HIV Prevention Programs
Background: Accurate HIV point of care testing is the cornerstone of prevention and treatment efforts globally, although false (both negative and positive) results are expected to occur. Setting: We assessed the spectrum of true and false positive HIV results in a large prospective study of HIV incidence in African women using 3 contraceptive methods tested longitudinally in Eswatini, Kenya, South Africa, and Zambia. Methods: HIV serologic testing was conducted quarterly using 2 parallel rapid HIV tests. When one or both tests were positive, additional confirmatory testing was conducted, including HIV enzyme immunoassay (EIA) and RNA. Results: A total of 7730 women contributed 48,234 visits: true positive results occurred at 412 visits (0.9%) and false positives at 96 visits (0.2%). Of 412 women with HIV seroconversion, 10 had discordant (ie, 1 negative and 1 positive) rapid tests and 13 had undetectable HIV RNA levels. Of 62 women with false positive rapid HIV results, most had discordant rapid testing, but 6 (9.7%) had dually positive rapid results, and 4 (6.5%) had false positive or indeterminate EIA results. The positive predictive value of dual positive rapid results was 98.3%. Conclusions: Although most rapid test results were accurate, false positive results were expected and occurred in this population of initially HIV seronegative individuals tested repeatedly and prospectively. When HIV infection occurred, not all cases had textbook laboratory results. Our findings highlight the importance of confirmatory testing, particularly for individuals undergoing repeat testing and in settings where the point prevalence is expected to be low. Trial registration: ClinicalTrials.gov number NCT02550067.
- Top Cited Papers
- 27 August 2024
- Published by American Medical Association (AMA) in JAMA
- Vol. 332 (8) , 649-657
Diagnostic Accuracy of an Integrated AI Tool to Estimate Gestational Age From Blind Ultrasound Sweeps
Importance: Accurate assessment of gestational age (GA) is essential to good pregnancy care but often requires ultrasonography, which may not be available in low-resource settings. This study developed a deep learning artificial intelligence (AI) model to estimate GA from blind ultrasonography sweeps and incorporated it into the software of a low-cost, battery-powered device.Objective: To evaluate GA estimation accuracy of an AI-enabled ultrasonography tool when used by novice users with no prior training in sonography.Design, Setting, and Participants: This prospective diagnostic accuracy study enrolled 400 individuals with viable, single, nonanomalous, first-trimester pregnancies in Lusaka, Zambia, and Chapel Hill, North Carolina. Credentialed sonographers established the “ground truth” GA via transvaginal crown-rump length measurement. At random follow-up visits throughout gestation, including a primary evaluation window from 14 0/7 weeks’ to 27 6/7 weeks’ gestation, novice users obtained blind sweeps of the maternal abdomen using the AI-enabled device (index test) and credentialed sonographers performed fetal biometry with a high-specification machine (study standard).Main Outcomes and Measures: The primary outcome was the mean absolute error (MAE) of the index test and study standard, which was calculated by comparing each method’s estimate to the previously established GA and considered equivalent if the difference fell within a prespecified margin of ±2 days.Results: In the primary evaluation window, the AI-enabled device met criteria for equivalence to the study standard, with an MAE (SE) of 3.2 (0.1) days vs 3.0 (0.1) days (difference, 0.2 days [95% CI, −0.1 to 0.5]). Additionally, the percentage of assessments within 7 days of the ground truth GA was comparable (90.7% for the index test vs 92.5% for the study standard). Performance was consistent in prespecified subgroups, including the Zambia and North Carolina cohorts and those with high body mass index.Conclusions and Relevance: Between 14 and 27 weeks’ gestation, novice users with no prior training in ultrasonography estimated GA as accurately with the low-cost, point-of-care AI tool as credentialed sonographers performing standard biometry on high-specification machines. These findings have immediate implications for obstetrical care in low-resource settings, advancing the World Health Organization goal of ultrasonography estimation of GA for all pregnant people.Trial Registration: ClinicalTrials.gov Identifier: NCT05433519
- 27 August 2024
- Published by American Medical Association (AMA) in JAMA
- Vol. 332 (8) , 649-657
Top Cited PapersDiagnostic Accuracy of an Integrated AI Tool to Estimate Gestational Age From Blind Ultrasound Sweeps
Importance: Accurate assessment of gestational age (GA) is essential to good pregnancy care but often requires ultrasonography, which may not be available in low-resource settings. This study developed a deep learning artificial intelligence (AI) model to estimate GA from blind ultrasonography sweeps and incorporated it into the software of a low-cost, battery-powered device.Objective: To evaluate GA estimation accuracy of an AI-enabled ultrasonography tool when used by novice users with no prior training in sonography.Design, Setting, and Participants: This prospective diagnostic accuracy study enrolled 400 individuals with viable, single, nonanomalous, first-trimester pregnancies in Lusaka, Zambia, and Chapel Hill, North Carolina. Credentialed sonographers established the “ground truth” GA via transvaginal crown-rump length measurement. At random follow-up visits throughout gestation, including a primary evaluation window from 14 0/7 weeks’ to 27 6/7 weeks’ gestation, novice users obtained blind sweeps of the maternal abdomen using the AI-enabled device (index test) and credentialed sonographers performed fetal biometry with a high-specification machine (study standard).Main Outcomes and Measures: The primary outcome was the mean absolute error (MAE) of the index test and study standard, which was calculated by comparing each method’s estimate to the previously established GA and considered equivalent if the difference fell within a prespecified margin of ±2 days.Results: In the primary evaluation window, the AI-enabled device met criteria for equivalence to the study standard, with an MAE (SE) of 3.2 (0.1) days vs 3.0 (0.1) days (difference, 0.2 days [95% CI, −0.1 to 0.5]). Additionally, the percentage of assessments within 7 days of the ground truth GA was comparable (90.7% for the index test vs 92.5% for the study standard). Performance was consistent in prespecified subgroups, including the Zambia and North Carolina cohorts and those with high body mass index.Conclusions and Relevance: Between 14 and 27 weeks’ gestation, novice users with no prior training in ultrasonography estimated GA as accurately with the low-cost, point-of-care AI tool as credentialed sonographers performing standard biometry on high-specification machines. These findings have immediate implications for obstetrical care in low-resource settings, advancing the World Health Organization goal of ultrasonography estimation of GA for all pregnant people.Trial Registration: ClinicalTrials.gov Identifier: NCT05433519
- Open Access
- 27 January 2024
- Published by Springer Nature in npj Precision Oncology
- Vol. 8 (1) , 1-13
Diagnostic performance of deep learning in ultrasound diagnosis of breast cancer: a systematic review
Deep learning (DL) has been widely investigated in breast ultrasound (US) for distinguishing between benign and malignant breast masses. This systematic review of test diagnosis aims to examine the accuracy of DL, compared to human readers, for the diagnosis of breast cancer in the US under clinical settings. Our literature search included records from databases including PubMed, Embase, Scopus, and Cochrane Library. Test accuracy outcomes were synthesized to compare the diagnostic performance of DL and human readers as well as to evaluate the assistive role of DL to human readers. A total of 16 studies involving 9238 female participants were included. There were no prospective studies comparing the test accuracy of DL versus human readers in clinical workflows. Diagnostic test results varied across the included studies. In 14 studies employing standalone DL systems, DL showed significantly lower sensitivities in 5 studies with comparable specificities and outperformed human readers at higher specificities in another 4 studies; in the remaining studies, DL models and human readers showed equivalent test outcomes. In 12 studies that assessed assistive DL systems, no studies proved the assistive role of DL in the overall diagnostic performance of human readers. Current evidence is insufficient to conclude that DL outperforms human readers or enhances the accuracy of diagnostic breast US in a clinical setting. Standardization of study methodologies is required to improve the reproducibility and generalizability of DL research, which will aid in clinical translation and application.
- 27 January 2024
- Published by Springer Nature in npj Precision Oncology
- Vol. 8 (1) , 1-13
Open AccessDiagnostic performance of deep learning in ultrasound diagnosis of breast cancer: a systematic review
Deep learning (DL) has been widely investigated in breast ultrasound (US) for distinguishing between benign and malignant breast masses. This systematic review of test diagnosis aims to examine the accuracy of DL, compared to human readers, for the diagnosis of breast cancer in the US under clinical settings. Our literature search included records from databases including PubMed, Embase, Scopus, and Cochrane Library. Test accuracy outcomes were synthesized to compare the diagnostic performance of DL and human readers as well as to evaluate the assistive role of DL to human readers. A total of 16 studies involving 9238 female participants were included. There were no prospective studies comparing the test accuracy of DL versus human readers in clinical workflows. Diagnostic test results varied across the included studies. In 14 studies employing standalone DL systems, DL showed significantly lower sensitivities in 5 studies with comparable specificities and outperformed human readers at higher specificities in another 4 studies; in the remaining studies, DL models and human readers showed equivalent test outcomes. In 12 studies that assessed assistive DL systems, no studies proved the assistive role of DL in the overall diagnostic performance of human readers. Current evidence is insufficient to conclude that DL outperforms human readers or enhances the accuracy of diagnostic breast US in a clinical setting. Standardization of study methodologies is required to improve the reproducibility and generalizability of DL research, which will aid in clinical translation and application.
- Open Access
- 8 January 2024
- Published by Wiley in International Journal of Gynecology & Obstetrics
- Vol. 165 (3) , 1013-1021
Deep learning to estimate gestational age from fly‐to cineloop videos: A novel approach to ultrasound quality control
Objective: Low‐cost devices have made obstetric sonography possible in settings where it was previously unfeasible, but ensuring quality and consistency at scale remains a challenge. In the present study, we sought to create a tool to reduce substandard fetal biometry measurement while minimizing care disruption.Methods: We developed a deep learning artificial intelligence (AI) model to estimate gestational age (GA) in the second and third trimester from fly‐to cineloops—brief videos acquired during routine ultrasound biometry—and evaluated its performance in comparison to expert sonographer measurement. We then introduced random error into fetal biometry measurements and analyzed the ability of the AI model to flag grossly inaccurate measurements such as those that might be obtained by a novice.Results: The mean absolute error (MAE) of our model (±standard error) was 3.87 ± 0.07 days, compared to 4.80 ± 0.10 days for expert biometry (difference −0.92 days; 95% CI: −1.10 to −0.76). Based on simulated novice biometry with average absolute error of 7.5%, our model reliably detected cases where novice biometry differed from expert biometry by 10 days or more, with an area under the receiver operating characteristics curve of 0.93 (95% CI: 0.92, 0.95), sensitivity of 81.0% (95% CI: 77.9, 83.8), and specificity of 89.9% (95% CI: 88.1, 91.5). These results held across a range of sensitivity analyses, including where the model was provided suboptimal truncated fly‐to cineloops.Conclusions: Our AI model estimated GA more accurately than expert biometry. Because fly‐to cineloop videos can be obtained without any change to sonographer workflow, the model represents a no‐cost guardrail that could be incorporated into both low‐cost and commercial ultrasound devices to prevent reporting of most gross GA estimation errors.
- 8 January 2024
- Published by Wiley in International Journal of Gynecology & Obstetrics
- Vol. 165 (3) , 1013-1021
Open AccessDeep learning to estimate gestational age from fly‐to cineloop videos: A novel approach to ultrasound quality control
Objective: Low‐cost devices have made obstetric sonography possible in settings where it was previously unfeasible, but ensuring quality and consistency at scale remains a challenge. In the present study, we sought to create a tool to reduce substandard fetal biometry measurement while minimizing care disruption.Methods: We developed a deep learning artificial intelligence (AI) model to estimate gestational age (GA) in the second and third trimester from fly‐to cineloops—brief videos acquired during routine ultrasound biometry—and evaluated its performance in comparison to expert sonographer measurement. We then introduced random error into fetal biometry measurements and analyzed the ability of the AI model to flag grossly inaccurate measurements such as those that might be obtained by a novice.Results: The mean absolute error (MAE) of our model (±standard error) was 3.87 ± 0.07 days, compared to 4.80 ± 0.10 days for expert biometry (difference −0.92 days; 95% CI: −1.10 to −0.76). Based on simulated novice biometry with average absolute error of 7.5%, our model reliably detected cases where novice biometry differed from expert biometry by 10 days or more, with an area under the receiver operating characteristics curve of 0.93 (95% CI: 0.92, 0.95), sensitivity of 81.0% (95% CI: 77.9, 83.8), and specificity of 89.9% (95% CI: 88.1, 91.5). These results held across a range of sensitivity analyses, including where the model was provided suboptimal truncated fly‐to cineloops.Conclusions: Our AI model estimated GA more accurately than expert biometry. Because fly‐to cineloop videos can be obtained without any change to sonographer workflow, the model represents a no‐cost guardrail that could be incorporated into both low‐cost and commercial ultrasound devices to prevent reporting of most gross GA estimation errors.