C. Figueira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
C. Figueira has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Pedro Vaz
Instituto Superior Técnico, 1049-001 Lisbon, Portugal
3 shared publications - Mariana Baptista
Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, Estrada Nacional 10, km 139,7, Bobadela LRS 2695-066, Portugal
2 shared publications - Mónica Mendes
CEFITEC, Departamento de Física, NOVA School of Science and Technology, Universidade Nova de Lisboa, 2829-516 Caparica, Portugal
2 shared publications P. Madeira
Área de Diagnóstico por Imagem, Serviço de Radiologia do Hospital de São José, Centro Hospitalar de Lisboa Central, Lisbon, Portugal
2 shared publications- Pedro Teles
Departamento de Física e Astronomia da Faculdade de Ciências Universidade do Porto Porto Portugal
2 shared publications - Salvatore Di Maria
Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, Campus Tecnológico e Nuclear, Estrada Nacional 10, Km 139.7, 2695-066 Bobadela LRS, Portugal; Departamento de Engenharia e Ciências Nucleares, Instituto Superior Técnico, Universidade de Lisboa, Estrada Nacional 10, Km 139.7, 2695-066 Bobadela LRS, Portugal
2 shared publications
Latest Publications
- 16 April 2015
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 165 (1-4) , 210-215
Paediatric CT exposures: comparison between CTDIvoland SSDE methods using measurements and Monte Carlo simulations
Computed tomography (CT) is one of the most used techniques in medical diagnosis, and its use has become one of the main sources of exposure of the population to ionising radiation. This work concentrates on the paediatric patients, since children exhibit higher radiosensitivity than adults. Nowadays, patient doses are estimated through two standard CT dose index (CTDI) phantoms as a reference to calculate CTDI volume (CTDIvol) values. This study aims at improving the knowledge about the radiation exposure to children and to better assess the accuracy of the CTDIvol method. The effectiveness of the CTDIvol method for patient dose estimation was then investigated through a sensitive study, taking into account the doses obtained by three methods: CTDIvol measured, CTDIvol values simulated with Monte Carlo (MC) code MCNPX and the recent proposed method Size-Specific Dose Estimate (SSDE). In order to assess organ doses, MC simulations were executed with paediatric voxel phantoms.
- 16 April 2015
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 165 (1-4) , 210-215
Paediatric CT exposures: comparison between CTDIvoland SSDE methods using measurements and Monte Carlo simulations
Computed tomography (CT) is one of the most used techniques in medical diagnosis, and its use has become one of the main sources of exposure of the population to ionising radiation. This work concentrates on the paediatric patients, since children exhibit higher radiosensitivity than adults. Nowadays, patient doses are estimated through two standard CT dose index (CTDI) phantoms as a reference to calculate CTDI volume (CTDIvol) values. This study aims at improving the knowledge about the radiation exposure to children and to better assess the accuracy of the CTDIvol method. The effectiveness of the CTDIvol method for patient dose estimation was then investigated through a sensitive study, taking into account the doses obtained by three methods: CTDIvol measured, CTDIvol values simulated with Monte Carlo (MC) code MCNPX and the recent proposed method Size-Specific Dose Estimate (SSDE). In order to assess organ doses, MC simulations were executed with paediatric voxel phantoms.
- 25 March 2015
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 165 (1) , 175-181
Assessment of patient dose reduction by bismuth shielding in CT using measurements, GEANT4 and MCNPX simulations
This work reports on the use of two different Monte Carlo codes (GEANT4 and MCNPX) for assessing the dose reduction using bismuth shields in computer tomography (CT) procedures in order to protect radiosensitive organs such as eye lens, thyroid and breast. Measurements were performed using head and body PMMA phantoms and an ionisation chamber placed in five different positions of the phantom. Simulations were performed to estimate Computed Tomography Dose Index values using GEANT4 and MCNPX. The relative differences between measurements and simulations were <10 %. The dose reduction arising from the use of bismuth shielding ranges from 2 to 45 %, depending on the position of the bismuth shield. The percentage of dose reduction was more significant for the area covered by the bismuth shielding (36 % for eye lens, 39 % for thyroid and 45 % for breast shields).
- 25 March 2015
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 165 (1) , 175-181
Assessment of patient dose reduction by bismuth shielding in CT using measurements, GEANT4 and MCNPX simulations
This work reports on the use of two different Monte Carlo codes (GEANT4 and MCNPX) for assessing the dose reduction using bismuth shields in computer tomography (CT) procedures in order to protect radiosensitive organs such as eye lens, thyroid and breast. Measurements were performed using head and body PMMA phantoms and an ionisation chamber placed in five different positions of the phantom. Simulations were performed to estimate Computed Tomography Dose Index values using GEANT4 and MCNPX. The relative differences between measurements and simulations were <10 %. The dose reduction arising from the use of bismuth shielding ranges from 2 to 45 %, depending on the position of the bismuth shield. The percentage of dose reduction was more significant for the area covered by the bismuth shielding (36 % for eye lens, 39 % for thyroid and 45 % for breast shields).
- 23 July 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (16) , 5433-5448
Medical staff extremity dosimetry in CT fluoroscopy: an anthropomorphic hand voxel phantom study
This work aims to contribute to the study of the radiation dose distribution delivered to the hands of medical staff members during a general computed tomographic (CT) fluoroscopic guided procedure. In this study, both Monte Carlo simulations and measurements were performed. For free-in-air and computed tomography dose index (CTDI) body phantom measurements, a standard pencil ionization chamber (IC) 100 mm long was used. The CT scanner model was implemented using MCNPX (Monte Carlo N-Particle eXtended) and was successfully validated by comparing the simulated results with measurements. Subsequently, CT images of a hand, together with an anthropomorphic phantom, were voxelized and used with the MCNPX code for dose calculations. The hand dose distribution study was performed both by using thermo-luminescent detector measurements and Monte Carlo simulations. The validated simulation tool provides a new perspective for detailed investigations of CT-irradiation scenarios. Simulations show that there is a strong dose gradient, namely the even zones of the hand that are in precise vicinity to the x-ray beam only receive about 4% of the maximum dose delivered to adjacent areas which are directly exposed to the primary x-ray beam. Finally, the scatter contribution of the patient was also studied through MC simulations. The results show that for directly exposed parts of the hand surface, the dose is reduced by the body of the patient (due to the shielding), whereas the dose is increased by scattered radiation from the patient for parts of the skin that receive scattered radiation only.
- 23 July 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (16) , 5433-5448
Medical staff extremity dosimetry in CT fluoroscopy: an anthropomorphic hand voxel phantom study
This work aims to contribute to the study of the radiation dose distribution delivered to the hands of medical staff members during a general computed tomographic (CT) fluoroscopic guided procedure. In this study, both Monte Carlo simulations and measurements were performed. For free-in-air and computed tomography dose index (CTDI) body phantom measurements, a standard pencil ionization chamber (IC) 100 mm long was used. The CT scanner model was implemented using MCNPX (Monte Carlo N-Particle eXtended) and was successfully validated by comparing the simulated results with measurements. Subsequently, CT images of a hand, together with an anthropomorphic phantom, were voxelized and used with the MCNPX code for dose calculations. The hand dose distribution study was performed both by using thermo-luminescent detector measurements and Monte Carlo simulations. The validated simulation tool provides a new perspective for detailed investigations of CT-irradiation scenarios. Simulations show that there is a strong dose gradient, namely the even zones of the hand that are in precise vicinity to the x-ray beam only receive about 4% of the maximum dose delivered to adjacent areas which are directly exposed to the primary x-ray beam. Finally, the scatter contribution of the patient was also studied through MC simulations. The results show that for directly exposed parts of the hand surface, the dose is reduced by the body of the patient (due to the shielding), whereas the dose is increased by scattered radiation from the patient for parts of the skin that receive scattered radiation only.