Xi Xing
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xi Xing has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Herschel Rabitz
Department of Chemistry, Princeton University, Princeton, USA
4 shared publications - Anna M. Oschmann
Princeton University
2 shared publications - Caroline R. Bartman
Department of Chemistry, Princeton University, Princeton, NJ, USA; Lewis-Sigler Institute for Integrative Genomics, Princeton University, Princeton, NJ, USA; Ludwig Institute for Cancer Research, Princeton University, Princeton, NJ, USA; Department of Systems Pharmacology and Translational Therapeutics, University of Pennsylvania, Philadelphia, PA, USA
2 shared publications - Daoyi Dong
University of Technology Sydney
2 shared publications - Genyuan Li
Princeton University
2 shared publications - Joshua D. Rabinowitz
Department of Chemistry, Princeton University, Princeton, USA
2 shared publications
Latest Publications
- Open Access
- 25 March 2024
- Published by MDPI AG in Metabolites
- Vol. 14 (4) , 184
Selected Ion Monitoring for Orbitrap-Based Metabolomics
Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.
- 25 March 2024
- Published by MDPI AG in Metabolites
- Vol. 14 (4) , 184
Open AccessSelected Ion Monitoring for Orbitrap-Based Metabolomics
Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.
- Open Access
- 14 February 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Selected ion monitoring for orbitrap-based metabolomics
Orbitrap mass spectrometry in full scan mode enables simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet sensitivity remains limiting for many metabolites, including low concentration species, poor ionizers, and low fractional abundance isotope-labeled forms in isotope tracing studies. Here we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space charge effects, to decreased performance (signal loss, mass shift, ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using full scan to ensure broad metabolic coverage, in tandem with SIM for accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.
- 14 February 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessSelected ion monitoring for orbitrap-based metabolomics
Orbitrap mass spectrometry in full scan mode enables simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet sensitivity remains limiting for many metabolites, including low concentration species, poor ionizers, and low fractional abundance isotope-labeled forms in isotope tracing studies. Here we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space charge effects, to decreased performance (signal loss, mass shift, ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using full scan to ensure broad metabolic coverage, in tandem with SIM for accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.
- Open Access
Learning-based Quantum Robust Control: Algorithm, Applications and Experiments
Robust control design for quantum systems has been recognized as a key task in quantum information technology, molecular chemistry and atomic physics. In this paper, an improved differential evolution algorithm, referred to as \emph{msMS}\_DE, is proposed to search robust fields for various quantum control problems. In \emph{msMS}\_DE, multiple samples are used for fitness evaluation and a mixed strategy is employed for the mutation operation. In particular, the \emph{msMS}\_DE algorithm is applied to the control problems of (i) open inhomogeneous quantum ensembles and (ii) the consensus goal of a quantum network with uncertainties. Numerical results are presented to demonstrate the excellent performance of the improved machine learning algorithm for these two classes of quantum robust control problems. Furthermore, \emph{msMS}\_DE is experimentally implemented on femtosecond laser control applications to optimize two-photon absorption and control fragmentation of the molecule $\text{CH}_2\text{BrI}$. Experimental results demonstrate excellent performance of \emph{msMS}\_DE in searching for effective femtosecond laser pulses for various tasks.Open AccessLearning-based Quantum Robust Control: Algorithm, Applications and Experiments
Robust control design for quantum systems has been recognized as a key task in quantum information technology, molecular chemistry and atomic physics. In this paper, an improved differential evolution algorithm, referred to as \emph{msMS}\_DE, is proposed to search robust fields for various quantum control problems. In \emph{msMS}\_DE, multiple samples are used for fitness evaluation and a mixed strategy is employed for the mutation operation. In particular, the \emph{msMS}\_DE algorithm is applied to the control problems of (i) open inhomogeneous quantum ensembles and (ii) the consensus goal of a quantum network with uncertainties. Numerical results are presented to demonstrate the excellent performance of the improved machine learning algorithm for these two classes of quantum robust control problems. Furthermore, \emph{msMS}\_DE is experimentally implemented on femtosecond laser control applications to optimize two-photon absorption and control fragmentation of the molecule $\text{CH}_2\text{BrI}$. Experimental results demonstrate excellent performance of \emph{msMS}\_DE in searching for effective femtosecond laser pulses for various tasks. - Open Access
Learning control of quantum systems using frequency-domain optimization algorithms
We investigate two classes of quantum control problems by using frequency-domain optimization algorithms in the context of ultrafast laser control of quantum systems. In the first class, the system model is known and a frequency-domain gradient-based optimization algorithm is applied to searching for an optimal control field to selectively and robustly manipulate the population transfer in atomic Rubidium. The other class of quantum control problems involves an experimental system with an unknown model. In the case, we introduce a differential evolution algorithm with a mixed strategy to search for optimal control fields and demonstrate the capability in an ultrafast laser control experiment for the fragmentation of Pr(hfac)$_3$ molecules.
Open AccessLearning control of quantum systems using frequency-domain optimization algorithms
We investigate two classes of quantum control problems by using frequency-domain optimization algorithms in the context of ultrafast laser control of quantum systems. In the first class, the system model is known and a frequency-domain gradient-based optimization algorithm is applied to searching for an optimal control field to selectively and robustly manipulate the population transfer in atomic Rubidium. The other class of quantum control problems involves an experimental system with an unknown model. In the case, we introduce a differential evolution algorithm with a mixed strategy to search for optimal control fields and demonstrate the capability in an ultrafast laser control experiment for the fragmentation of Pr(hfac)$_3$ molecules.
- 22 September 2016
- Published by Springer Nature in Journal of Mathematical Chemistry
- Vol. 55 (1) , 278-303
High dimensional model representation constructed by support vector regression. I. Independent variables with known probability distributions
- 22 September 2016
- Published by Springer Nature in Journal of Mathematical Chemistry
- Vol. 55 (1) , 278-303
High dimensional model representation constructed by support vector regression. I. Independent variables with known probability distributions
- 4 July 2015
- Published by Springer Nature in Journal of Mathematical Chemistry
- Vol. 53 (8) , 1885-1914
Sparse and nonnegative sparse D-MORPH regression
- 4 July 2015
- Published by Springer Nature in Journal of Mathematical Chemistry
- Vol. 53 (8) , 1885-1914
Sparse and nonnegative sparse D-MORPH regression