AMAndres Müller

Andres Müller

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andres Müller has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Investigation of the Time Resolution Set Up Used to Compute the Full Load Vortex Rope in a Francis Turbine

    by Jean Decaix, Andres Müller, Arthur Favrel, François Avellan, Cécile Münch-Alligné

    The flow in a Francis turbine at full load is characterised by the development of an axial vortex rope in the draft tube. The vortex rope often promotes cavitation if the turbine is operated at a sufficiently low Thoma number. Furthermore, the vortex rope can evolve from a stable to an unstable behaviour. For CFD, such a flow is a challenge since it requires solving an unsteady cavitating flow including rotor/stator interfaces. Usually, the numerical investigations focus on the cavitation model or the turbulence model. In the present works, attention is paid to the strategy used for the time integration. The vortex rope considered is an unstable cavitating one that develops downstream the runner. The vortex rope shows a periodic behaviour characterized by the development of the vortex rope followed by a strong collapse leading to the shedding of bubbles from the runner area. Three unsteady RANS simulations are performed using the ANSYS CFX 17.2 software. The turbulence and cavitation models are, respectively, the SST and Zwart models. Regarding the time integration, a second order backward scheme is used excepted for the transport equation for the liquid volume fraction, for which a first order backward scheme is used. The simulations differ by the time step and the number of internal loops per time step. One simulation is carried out with a time step equal to one degree of revolution per time step and five internal loops. A second simulation used the same time step but 15 internal loops. The third simulations used three internal loops and an adaptive time step computed based on a maximum CFL lower than 2. The results show an influence of the time integration strategy on the cavitation volume time history both in the runner and in the draft tube with a risk of divergence of the solution if a standard set up is used.


  • Evaluation of a Dynamic Transfer Matrix for a Hydraulic Turbine

    by Keita Yamamoto, Koichi Yonezawa, Andres Müller, François Avellan, Yoshinobu Tsujimoto

    It is well known that hydraulic machines experience various types of flow instabilities causing a negative influence on the system under off-design operations. The transfer matrix method correlating the flow properties in upstream and downstream of hydraulic machines is widely adopted as a first step to investigate dynamical characteristics of flow. Transfer matrix elements are the key to understand hydraulic system stability. This study focuses on measurements of transfer matrix elements for a hydraulic turbine. The oscillations of the flowrate are produced by two flow exciters located in upstream and downstream of the turbine, and evaluated from the fluctuations of the pressure difference across two streamwise locations. It is shown that the transfer matrices are successfully evaluated at part load and full load operations in the presence and absence of cavitation. In particular, cavitation compliance and mass flow gain factor, which determine the dynamical response of cavitation to the change of pressure and flowrate, are calculated from the measured transfer matrix elements. The absolute value of both cavitation compliance and mass flow gain factor is found to increase with respect to the decrease of the cavitation number. The phase of the mass flow gain factor is delayed as the excitation frequency increases. This suggests that hydraulic systems may be stabilized when the oscillation frequency increases. As a result of stability analyses, it is demonstrated that the mass flow gain factor plays a crucial role, especially in the full load cavitation surge.


  • Physical Mechanism of Interblade Vortex Development at Deep Part Load Operation of a Francis Turbine

    by Keita Yamamoto, Andres Müller, Arthur Favrel, François Avellan

    For seamless integration of growing electricity production from intermittent renewable energy sources, Francis turbines are under increasing demand to extend their operating range. This requires Francis turbines to operate under off-design conditions, where various types of cavitation are induced. At deep part load condition, an interblade cavitation vortex observed in a runner blade channel is a typical cavitation phenomenon causing pressure fluctuations and erosion, which prevent a reliable operation of Francis turbines at deep part load. The underlying mechanisms of its development are, however, yet to be understood. In an objective of revealing its developing mechanisms, the present study is aimed at investigating flow structures inside runner blade channels by comparison of three different operating conditions at deep part load using numerical simulation results. After demonstrating interblade vortex structures are successfully simulated by performed computations, it is shown that flow inside the runner at deep part load operation is characterized by a remarkable development of recirculating flow on the hub near the runner outlet. This recirculating flow is concluded to be closely associated with interblade vortex development. The skin-friction analyses applied to the hub identify the flow separation caused by a nonuniform distribution of flow, which describes the underlying physical mechanism of interblade vortex development. Investigations are further extended to include a quantitative evaluation of the specific energy loss induced by interblade vortex development. The integration of energy flux defined by rothalpy evidences the energy loss due to the presence of strong interblade vortex structures.


  • URANS Models for the Simulation of Full Load Pressure Surge in Francis Turbines Validated by Particle Image Velocimetry

    by J. Decaix, A. Müller, A. Favrel, F. Avellan, C. Münch

    Due to the penetration of alternative renewable energies, the stabilization of the electrical power network relies on the off-design operation of turbines and pump-turbines in hydro-power plants. The occurrence of cavitation is however a common phenomenon at such operating conditions, often leading to critical flow instabilities which undercut the grid stabilizing capacity of the power plant. In order to predict and extend the stable operating range of hydraulic machines, a better understanding of the cavitating flows and mainly of the transition between stable and unstable flow regimes is required. In the case of Francis turbines operating at full load, an axisymmetric cavitation vortex rope develops at the runner outlet. The cavity may enter self-oscillation, with violent periodic pressure pulsations. The flow fluctuations lead to dangerous electrical power swings and mechanical vibrations, dictating an inconvenient and costly restriction of the operating range. The present paper reports an extensive numerical and experimental investigation on a reduced scale model of a Francis turbine at full load. For a given operating point, three pressure levels in the draft tube are considered, two of them featuring a stable flow configuration and one of them displaying a self-excited oscillation of the cavitation vortex rope. The velocity field is measured by two-dimensional (2D) particle image velocimetry (PIV) and systematically compared to the results of a simulation based on a homogeneous unsteady Reynolds-averaged Navier–Stokes (URANS) model. The validation of the numerical approach enables a first comprehensive analysis of the flow transition as well as an attempt to explain the onset mechanism.


  • New insight in Francis turbine cavitation vortex rope: role of the runner outlet flow swirl number

    by Arthur Favrel, Joao Gomes Pereira Junior, Christian Landry, Andres Müller, Christophe Nicolet, François Avellan

    At part load operation, Francis turbines experience the development of a cavitation vortex rope in the draft tube, whose precession acts as a pressure excitation source. In case of resonance, the resulting pressure pulsations lead to unacceptable torque and power fluctuations on the prototype machine, putting at risk the system stability. However, the accurate prediction of resonance conditions at the prototype scale remains challenging since it requires a proper hydro-acoustic modelling of the draft tube cavitation flow. Furthermore, both the head and discharge values have an impact on the precession frequency of the vortex and the natural frequency of the system. The present paper demonstrates for the first time that the influence of both parameters on the frequencies of interest can be represented by a single parameter, the swirl number. Its analytical expression is derived as a function of the operating parameters of the machine. It is used to establish empirical laws enabling the determination of both frequencies and finally the operating parameters in resonance conditions on the complete part load operating range at the model scale. The methodology presented in this paper represents a decisive step towards the prediction of resonances on the complete part load operating range of the prototype.


  • Local wave speed and bulk flow viscosity in Francis turbines at part load operation

    by Christian Landry, Arthur Favrel, Andres Müller, Christophe Nicolet, François Avellan

    The operation of Francis turbines at off-design conditions may cause the development of a cavitation vortex rope in the draft tube cone, acting as a pressure excitation source. The interactions between this excitation source and the hydraulic system at the natural frequency may result in resonance phenomena, causing serious hydro-mechanical oscillations. One-dimensional draft tube models for the simulation and prediction of part load resonances require an accurate modelling of the wave speed and the bulk viscosity for the draft tube flow. This paper introduces a new methodology for determining these two hydroacoustic parameters in the draft tube of a reduced scale physical model of a Francis turbine, based on experimental identification of the hydraulic natural frequency of the test rig. Finally, dimensionless numbers are derived to define both the wave speed and bulk viscosity for different operating points of the turbine.


  • Measurement of the Self-Oscillating Vortex Rope Dynamics for Hydroacoustic Stability Analysis

    by Andres Müller, Keita Yamamoto, Sébastien Alligné, Koichi Yonezawa, Yoshinobu Tsujimoto, François Avellan

    Flow instabilities in hydraulic machines often feature oscillating cavitation volumes, which locally introduce compliance and mass flow gain effects. These unsteady characteristics play a crucial role in one-dimensional stability models and can be determined through the definition of transfer functions for the state variables, where the cavitation volume is commonly estimated from the discharge difference between two points located upstream and downstream of the cavity. This approach is demonstrated on a test rig with a microturbine, featuring a self-oscillating vortex rope in its conical draft tube. The fluctuating discharges at the turbine inlet and the draft tube outlet are determined with the pressure–time method using differential pressure transducers. The cavitation volume is then calculated by integrating the corresponding discharge difference over time. In order to validate the results, an alternative volume approximation method is presented, based on the image processing of a high-speed flow visualization. In this procedure, the edges of the vortex rope are detected to calculate the local cross section areas of the cavity. It is shown that the cavitation volumes obtained by the two methods are in good agreement. Thus, the fluctuating part of the cavitation volume oscillation can be accurately estimated by integrating the difference between the volumetric upstream and downstream discharges. Finally, the volume and discharge fluctuations from the pressure–time method are averaged over one mean period of the pressure oscillation. This enables an analysis of the key physical flow parameters’ behavior over one characteristic period of the instability and a discussion of its sustaining mechanisms.


  • Experimental method for the evaluation of the dynamic transfer matrix using pressure transducers

    by Keita Yamamoto, Andres Müller, Takuya Ashida, Koichi Yonezawa, François Avellan, Yoshinobu Tsujimoto

    This paper introduces an experimental method for the evaluation of dynamic transfer matrices using only pressure transducers. The discharge fluctuations are evaluated from the fluctuation of the pressure difference at different streamwise locations. The transfer matrices of the resistance, the inertance and the compliance elements are determined by using simple flow configurations. This method is then validated by comparing the transfer matrix components to theoretical values. The results show that the direct measurement of the transfer matrices produces good results below the first structural eigenfrequency of the system. Furthermore, a deviation from the mass continuity in the amplitude ratio of the fluctuating upstream and downstream discharges is investigated. This behaviour can be explained with a simple model taking into account the compliance in the system.