DKDieuwke Kornelis

Dieuwke Kornelis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dieuwke Kornelis has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Specificity of the Point-of-Care Urine Strip Test for Schistosoma Circulating Cathodic Antigen (POC-CCA) Tested in Non-Endemic Pregnant Women and Young Children

    by Miriam Casacuberta-Partal, Margreet Beenakker, Claudia J. de Dood, Pytsje T. Hoekstra, Lisa Kroon, Dieuwke Kornelis, Paul Corstjens, Cornelis H. Hokke, Govert J. van Dam, Meta Roestenberg, et al.

    The point-of-care urine based strip test for the detection of circulating cathodic antigen (POC-CCA) in schistosome infections is a frequently used tool for diagnosis and mapping of Schistosoma mansoni in school-aged children. Because of its ease of use, the test is increasingly applied to adults and preschool-aged children (PSAC), but its performance has not been specifically evaluated in these target groups. Recent observations have raised concerns about possible reduced specificity, in particular in pregnant women (PW) and PSAC. We thus explored specificity of the POC-CCA urine strip test (Rapid Medical Diagnostics, Pretoria, South Africa) in a non-endemic, nonexposed population of 47 healthy nonpregnant adults (NPAs), 52 PW, and 58 PSAC. A total of 157 urines were tested with POC-CCA, of which five (10.6%) NPAs, 17 (32.7%) PW, and 27 (46.5%) PSAC were positive. The highest scores were found in the youngest babies, with an infant of 9 months being the oldest positive case. On measuring pH, it appeared that all POC-CCA strongly positive urines were acidic (pH range 5–5.5), whereas addition of pH-neutral buffer to a subsample reversed the false positivity. We conclude that the POC-CCA test has reduced specificity in PW and infants younger than 9 months, but that the false positivity might be eliminated by modifications in the buffers used in the test.


  • Open Access

    Latent class analysis to evaluate performance of point-of-care CCA for low-intensity Schistosoma mansoni infections in Burundi

    by Michelle N. Clements, Paul L. A. M. Corstjens, Sue Binder, Carl H. Campbell, Claudia J. de Dood, Alan Fenwick, Wendy Harrison, Donatien Kayugi, Charles H. King, Dieuwke Kornelis, et al.

    Kato-Katz examination of stool smears is the field-standard method for detecting Schistosoma mansoni infection. However, Kato-Katz misses many active infections, especially of light intensity. Point-of-care circulating cathodic antigen (CCA) is an alternative field diagnostic that is more sensitive than Kato-Katz when intensity is low, but interpretation of CCA-trace results is unclear. To evaluate trace results, we tested urine and stool specimens from 398 pupils from eight schools in Burundi using four approaches: two in Burundi and two in a laboratory in Leiden, the Netherlands. In Burundi, we used Kato-Katz and point-of-care CCA (CCAB). In Leiden, we repeated the CCA (CCAL) and also used Up-Converting Phosphor Circulating Anodic Antigen (CAA). We applied Bayesian latent class analyses (LCA), first considering CCA traces as negative and then as positive. We used the LCA output to estimate validity of the prevalence estimates of each test in comparison to the population-level infection prevalence and estimated the proportion of trace results that were likely true positives. Kato-Katz yielded the lowest prevalence (6.8%), and CCAB with trace considered positive yielded the highest (53.5%). There were many more trace results recorded by CCA in Burundi (32.4%) than in Leiden (2.3%). Estimated prevalence with CAA was 46.5%. LCA indicated that Kato-Katz had the lowest sensitivity: 15.9% [Bayesian Credible Interval (BCI): 9.2–23.5%] with CCA-trace considered negative and 15.0% with trace as positive (BCI: 9.6–21.4%), implying that Kato-Katz missed approximately 85% of infections. CCAB underestimated disease prevalence when trace was considered negative and overestimated disease prevalence when trace was considered positive, by approximately 12 percentage points each way, and CAA overestimated prevalence in both models. Our results suggest that approximately 52.2% (BCI: 37.8–5.8%) of the CCAB trace readings were true infections. Whether measured in the laboratory or the field, CCA outperformed Kato-Katz at the low infection intensities in Burundi. CCA with trace as negative likely missed many infections, whereas CCA with trace as positive overestimated prevalence. In the absence of a field-friendly gold standard diagnostic, the use of a variety of diagnostics with differing properties will become increasingly important as programs move towards elimination of schistosomiasis. It is clear that CCA is a valuable tool for the detection and mapping of S. mansoni infection in the field and CAA may be a valuable field tool in the future.


  • Correlation of serum and dried blood spot results for quantitation of Schistosoma circulating anodic antigen: A proof of principle

    by Jennifer A. Downs, Paul L.A.M. Corstjens, Julius Mngara, Peter Lutonja, Raphael Isingo, Mark Urassa, Dieuwke Kornelis, Govert J. van Dam