Xingguo Feng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xingguo Feng has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Xiangyu Lu
Jiangsu University of Science and Technology
10 shared publications Da Chen
3 shared publicationsNing Zhuang
Key Laboratory of Coastal Disaster and Defence, Ministry of Education, College of Harbour, Coastal and Offshore Engineering , 12462 Hohai University , Nanjing , 210024 , Jiangsu , China
3 shared publications- Yu Zuo
Key Laboratory of Carbon Fiber and Functional Polymer, Ministry of Education, Beijing University of Chemical Technology, Beijing 100029, China
3 shared publications Xiangyu Lu
Key Laboratory of Coastal Disaster and Defence, Ministry of Education, College of Harbour, Coastal and Offshore Engineering , 12462 Hohai University , Nanjing , 210024 , Jiangsu , China
2 shared publicationsYang Zhao
Key Laboratory of Coastal Disaster and Defence, Ministry of Education, Hohai University, Nanjing 210024 Jiangsu, People’s Republic of China
2 shared publications
Latest Publications
- Open Access
Long-Lifetime Ag/AgCl Electrodes Prepared by Pulse Current Electrodeposition for Chloride Monitoring in the Concrete Environment
Lifetimes of Ag/AgCl electrodes determine whether it is possible to monitor the concentration of chloride ions in marine concrete structures. A novel manufacturing method, pulse current electrodeposition at a low current density, was proposed to prepare the long-lifetime Ag/AgCl electrode. Influences of electrodeposition duration were investigated on the Nernst response, exchange current density, and lifetime of Ag/AgCl electrodes, and the properties were also compared to those of the ones electrodeposited by applying constant currents. Ag/AgCl electrodes prepared with the pulse current exhibited a wider potential response, a higher exchange current density, and a longer lifetime than those prepared by the constant current under the same equivalent charge transfer conditions. AgCl film on the electrode prepared with the pulse current displayed a thicker layer, a lower density of micropores, a higher Cl/O ratio, and a lower Ag/Cl ratio than those of its counterpart electrodeposited by applying the constant current. The lifetime of the Ag/AgCl electrode was mainly determined by the thickness of AgCl films in the concrete environment. The lifetimes of the Ag/AgCl electrode, which was prepared with a 0.1 mA cm−2 pulse current for 15 h, were 420 h in pore solution and more than 3500 h in mortar, respectively. In addition, the potential of this Ag/AgCl electrode did not show any significant decrease after 3500 h in the mortar without Cl−. The results suggest that pulse current electrodeposition is an effective method to improve the lifetimes of Ag/AgCl electrodes in concrete.
Open AccessLong-Lifetime Ag/AgCl Electrodes Prepared by Pulse Current Electrodeposition for Chloride Monitoring in the Concrete Environment
Lifetimes of Ag/AgCl electrodes determine whether it is possible to monitor the concentration of chloride ions in marine concrete structures. A novel manufacturing method, pulse current electrodeposition at a low current density, was proposed to prepare the long-lifetime Ag/AgCl electrode. Influences of electrodeposition duration were investigated on the Nernst response, exchange current density, and lifetime of Ag/AgCl electrodes, and the properties were also compared to those of the ones electrodeposited by applying constant currents. Ag/AgCl electrodes prepared with the pulse current exhibited a wider potential response, a higher exchange current density, and a longer lifetime than those prepared by the constant current under the same equivalent charge transfer conditions. AgCl film on the electrode prepared with the pulse current displayed a thicker layer, a lower density of micropores, a higher Cl/O ratio, and a lower Ag/Cl ratio than those of its counterpart electrodeposited by applying the constant current. The lifetime of the Ag/AgCl electrode was mainly determined by the thickness of AgCl films in the concrete environment. The lifetimes of the Ag/AgCl electrode, which was prepared with a 0.1 mA cm−2 pulse current for 15 h, were 420 h in pore solution and more than 3500 h in mortar, respectively. In addition, the potential of this Ag/AgCl electrode did not show any significant decrease after 3500 h in the mortar without Cl−. The results suggest that pulse current electrodeposition is an effective method to improve the lifetimes of Ag/AgCl electrodes in concrete.
- 1 October 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (10) , 100506
Investigation of SDS on Corrosion Behavior and Discharge Performance of AZ31B Magnesium Alloys in Aqueous Magnesium Air Batteries
To address the issue of high self-corrosion rate of Mg anodes in seawater batteries leading to low discharge efficiency, the green inhibitor, sodium dodecyl sulfate (SDS), was utilized to enhance the discharging performance of AZ31B alloy. The addition of SDS in a 3.5% NaCl solution led to a reduction in the corrosion rate of AZ31B alloy due to the formation of S-containing compounds. During the continuous-discharging period, the addition of 0.05 M SDS increased the anodic utilization efficiency from 64% to 81% and the specific energy density of the entire battery elevated from 1280 to 1912 mAh g−1 (an increase of 49%). The enhancement of the discharge performance of AZ31B Mg alloy in a 3.5% NaCl solution by SDS can be attributed to three aspects: reducing the negative difference effect of the Mg alloy, decreasing the accumulation of corrosion products on the surface of the Mg alloy, and promoting a more uniform dissolution of the Mg alloy.
- 1 October 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (10) , 100506
Investigation of SDS on Corrosion Behavior and Discharge Performance of AZ31B Magnesium Alloys in Aqueous Magnesium Air Batteries
To address the issue of high self-corrosion rate of Mg anodes in seawater batteries leading to low discharge efficiency, the green inhibitor, sodium dodecyl sulfate (SDS), was utilized to enhance the discharging performance of AZ31B alloy. The addition of SDS in a 3.5% NaCl solution led to a reduction in the corrosion rate of AZ31B alloy due to the formation of S-containing compounds. During the continuous-discharging period, the addition of 0.05 M SDS increased the anodic utilization efficiency from 64% to 81% and the specific energy density of the entire battery elevated from 1280 to 1912 mAh g−1 (an increase of 49%). The enhancement of the discharge performance of AZ31B Mg alloy in a 3.5% NaCl solution by SDS can be attributed to three aspects: reducing the negative difference effect of the Mg alloy, decreasing the accumulation of corrosion products on the surface of the Mg alloy, and promoting a more uniform dissolution of the Mg alloy.
- 11 March 2024
- Published by Walter de Gruyter GmbH in Corrosion Reviews
- Vol. 42 (3) , 355-369
Repassivation characteristics of carbon steel in chloride-free pore solution after thermal cycles of simulated tropical marine environments
Repassivation characteristics of carbon steel experienced thermal cycles in tropical marine environments were investigated in a simulated concrete pore solution (SCPS). The results suggested that the damage of passive films on the carbon steel mainly occurred during the cooling process in thermal cycles. The damaged passive films gradually recovered in the SCPS, and the duration of repassivation extended with the amplitude of thermal cycles and cyclic number in the high-amplitude thermal cycles (20–60 °C and 20–70 °C), while it was not significantly affected by the cyclic number in the low-amplitude thermal cycles (20–40 °C and 20–50 °C).
- 11 March 2024
- Published by Walter de Gruyter GmbH in Corrosion Reviews
- Vol. 42 (3) , 355-369
Repassivation characteristics of carbon steel in chloride-free pore solution after thermal cycles of simulated tropical marine environments
Repassivation characteristics of carbon steel experienced thermal cycles in tropical marine environments were investigated in a simulated concrete pore solution (SCPS). The results suggested that the damage of passive films on the carbon steel mainly occurred during the cooling process in thermal cycles. The damaged passive films gradually recovered in the SCPS, and the duration of repassivation extended with the amplitude of thermal cycles and cyclic number in the high-amplitude thermal cycles (20–60 °C and 20–70 °C), while it was not significantly affected by the cyclic number in the low-amplitude thermal cycles (20–40 °C and 20–50 °C).
- 24 March 2022
- Published by Walter de Gruyter GmbH in Corrosion Reviews
- Vol. 40 (3) , 247-262
Pitting initiation on 304 stainless steel in a chloride-contaminated pore solution under alternating temperature conditions
Pitting initiation on 304 stainless steel grades was investigated in alternating temperature pore solutions to simulate pitting on stainless steel rebar in a tropical marine environment. The results suggested that a larger amplitude of alternating temperature heavily doped the passive film, reduced the film’s thickness and increased the (Fe 3+ ox + Fe 3+ hy)/Fe 2+ ox and Cr 3+ hy/Cr 3+ ox ratios in the film. Alternating temperatures more significantly degraded the passive film and intensified the pitting sensitivity on the stainless steel when compared with the average temperatures of the alternating temperature cycles. More pitting initiation sites were observed on the samples that experienced the 22–60 °C and 22–70 °C alternating temperature cycles than their counterparts in 50 °C and 60 °C solutions, respectively.
- 24 March 2022
- Published by Walter de Gruyter GmbH in Corrosion Reviews
- Vol. 40 (3) , 247-262
Pitting initiation on 304 stainless steel in a chloride-contaminated pore solution under alternating temperature conditions
Pitting initiation on 304 stainless steel grades was investigated in alternating temperature pore solutions to simulate pitting on stainless steel rebar in a tropical marine environment. The results suggested that a larger amplitude of alternating temperature heavily doped the passive film, reduced the film’s thickness and increased the (Fe 3+ ox + Fe 3+ hy)/Fe 2+ ox and Cr 3+ hy/Cr 3+ ox ratios in the film. Alternating temperatures more significantly degraded the passive film and intensified the pitting sensitivity on the stainless steel when compared with the average temperatures of the alternating temperature cycles. More pitting initiation sites were observed on the samples that experienced the 22–60 °C and 22–70 °C alternating temperature cycles than their counterparts in 50 °C and 60 °C solutions, respectively.
- 1 February 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (2) , 021507
Corrosion Performance of 201 low-Nickel Stainless Steel Anchor in Cl – Contaminated Underground Water with Various Concentrations of SO 4 2− and HCO 3 −
Corrosion behavior of 201 low-nickel stainless steel was studied in Cl − -contaminated underground water with various concentrations of HCO 3 − and SO 4 2− at different pHs to investigate the durability of stainless-steel anchors. The charge-transfer resistance increased, whereas the carrier densities and corrosion current density decreased with an increase in concentration of HCO 3 − and SO 4 2− , and solution pH. A parameter that was termed the composite corrosiveness index ( CCI ) was proposed to assess the corrosivity of underground waters to stainless steels. The CCI exhibited a monotonic relationship with charge-transfer resistance, carrier density, and corrosion current density, and it was more suitable for stainless steels compared with previous corrosiveness indexes in underground waters.
- 1 February 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (2) , 021507
Corrosion Performance of 201 low-Nickel Stainless Steel Anchor in Cl – Contaminated Underground Water with Various Concentrations of SO 4 2− and HCO 3 −
Corrosion behavior of 201 low-nickel stainless steel was studied in Cl − -contaminated underground water with various concentrations of HCO 3 − and SO 4 2− at different pHs to investigate the durability of stainless-steel anchors. The charge-transfer resistance increased, whereas the carrier densities and corrosion current density decreased with an increase in concentration of HCO 3 − and SO 4 2− , and solution pH. A parameter that was termed the composite corrosiveness index ( CCI ) was proposed to assess the corrosivity of underground waters to stainless steels. The CCI exhibited a monotonic relationship with charge-transfer resistance, carrier density, and corrosion current density, and it was more suitable for stainless steels compared with previous corrosiveness indexes in underground waters.
- Open Access
Electrochemical Study of Stainless Steel Anchor Bolt Corrosion Initiation in Corrosive Underground Water
Application of low-nickel stainless steel anchor was one of the economical and effective methods to solve the durability problem of slope engineering. At present, there are scarce reports about corrosion characteristics of low-nickel stainless steel in various underground waters. For investigating the corrosion initiation of stainless steel anchor bolt in corrosive underground water, the effect of SO42−, HCO3− and pH value on the corrosion behavior of 201 low-nickel stainless steel was studied via electrochemical methods. As the SO42− concentration, HCO3− concentration or pH value increase, the open circuit potential and polarization resistance increase, while the double-layer capacitance, donor density and passive current density decrease. The results indicate that corrosion is inhibited by SO42−, HCO3− and OH− in underground water. In addition, the inhibitive efficiency of SO42− and HCO3− increases with the SO42− and HCO3− concentration.
Open AccessElectrochemical Study of Stainless Steel Anchor Bolt Corrosion Initiation in Corrosive Underground Water
Application of low-nickel stainless steel anchor was one of the economical and effective methods to solve the durability problem of slope engineering. At present, there are scarce reports about corrosion characteristics of low-nickel stainless steel in various underground waters. For investigating the corrosion initiation of stainless steel anchor bolt in corrosive underground water, the effect of SO42−, HCO3− and pH value on the corrosion behavior of 201 low-nickel stainless steel was studied via electrochemical methods. As the SO42− concentration, HCO3− concentration or pH value increase, the open circuit potential and polarization resistance increase, while the double-layer capacitance, donor density and passive current density decrease. The results indicate that corrosion is inhibited by SO42−, HCO3− and OH− in underground water. In addition, the inhibitive efficiency of SO42− and HCO3− increases with the SO42− and HCO3− concentration.
- 10 February 2021
- Published by Walter de Gruyter GmbH in Corrosion Reviews
- Vol. 39 (2) , 149-164
Effect of interaction between two single-particle-impingements on the repassivation behavior of 304 stainless steel in a simulated groundwater
To investigate the effect of interaction between two single-Si 3 N 4 particle-impingements on the repassivation of 304 stainless steel in a simulated groundwater, the corrosion current peaks of the samples during the impingement were recorded, and the micro-hardness of the substrate around the crater was tested. The results indicated that significant interactions between the two impingements were observed only when the value of distance-diameter ratio ( L/d ) was less than 1.5. With L/d being less than 1.5, the corrosion current peaks and mass losses due to the second impingements were higher than those of the first ones, and the re-passivation rates of samples during the second impingements were lower than those of the first impingements. Simultaneously, the microhardness of the substrate between the two craters was higher than that of the surface around one single crater with the same distance-diameter ratio. The mechanisms of how the L/d ratio influenced the interaction between the two impingements are also discussed.
- 10 February 2021
- Published by Walter de Gruyter GmbH in Corrosion Reviews
- Vol. 39 (2) , 149-164
Effect of interaction between two single-particle-impingements on the repassivation behavior of 304 stainless steel in a simulated groundwater
To investigate the effect of interaction between two single-Si 3 N 4 particle-impingements on the repassivation of 304 stainless steel in a simulated groundwater, the corrosion current peaks of the samples during the impingement were recorded, and the micro-hardness of the substrate around the crater was tested. The results indicated that significant interactions between the two impingements were observed only when the value of distance-diameter ratio ( L/d ) was less than 1.5. With L/d being less than 1.5, the corrosion current peaks and mass losses due to the second impingements were higher than those of the first ones, and the re-passivation rates of samples during the second impingements were lower than those of the first impingements. Simultaneously, the microhardness of the substrate between the two craters was higher than that of the surface around one single crater with the same distance-diameter ratio. The mechanisms of how the L/d ratio influenced the interaction between the two impingements are also discussed.
- Open Access
Investigation of Protective Performance of a Mg-Rich Primer Containing Aluminum Tri-Polyphosphate on AZ91D Magnesium Alloy in Simulated Acid Rain
Mg-rich primer (MRP) containing aluminum tri-polyphosphate functions via a galvanic mechanism to protect AZ91D alloy from corrosion in the 3 wt % NaCl solution. However, its protective performance can be strongly affected by the testing environment. Therefore, it is important to investigate the performance of the primer on magnesium alloys in an acid rain environment. In the present study, the protective performance of MRP with or without aluminum tri-polyphosphate was investigated via open circuit potential (OCP), electrochemical impedance spectroscopy (EIS), scanning electronic microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) in the simulated acid rain. Compared to the primer without aluminum tri-polyphosphate, the MRP containing aluminum tri-polyphosphate pigments exhibited better protective performance in the simulated acid rain condition. In the initial stage, the acidic condition prompted the aluminum tri-polyphosphate pigments to release phosphates and H+ to form magnesium phosphates on Mg particles, retarding their consumption rate. The Mg-rich primer with aluminum tri-polyphosphate can provide cathodic protection to AZ91D alloy for about 49 days in the simulated acid rain solution. Simultaneously, the corrosion products of Mg particles, magnesium oxides and phosphates, precipitated on the Mg particles and improved the stability of the primer. In addition, a protective film, consisting of magnesium oxides and phosphates, formed on the AZ91D substrate. Consequently, all these factors contributed to the long cathodic protection and improved corrosion resistance of MRP containing aluminum tri-polyphosphate in the simulated acid rain.
Open AccessInvestigation of Protective Performance of a Mg-Rich Primer Containing Aluminum Tri-Polyphosphate on AZ91D Magnesium Alloy in Simulated Acid Rain
Mg-rich primer (MRP) containing aluminum tri-polyphosphate functions via a galvanic mechanism to protect AZ91D alloy from corrosion in the 3 wt % NaCl solution. However, its protective performance can be strongly affected by the testing environment. Therefore, it is important to investigate the performance of the primer on magnesium alloys in an acid rain environment. In the present study, the protective performance of MRP with or without aluminum tri-polyphosphate was investigated via open circuit potential (OCP), electrochemical impedance spectroscopy (EIS), scanning electronic microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) in the simulated acid rain. Compared to the primer without aluminum tri-polyphosphate, the MRP containing aluminum tri-polyphosphate pigments exhibited better protective performance in the simulated acid rain condition. In the initial stage, the acidic condition prompted the aluminum tri-polyphosphate pigments to release phosphates and H+ to form magnesium phosphates on Mg particles, retarding their consumption rate. The Mg-rich primer with aluminum tri-polyphosphate can provide cathodic protection to AZ91D alloy for about 49 days in the simulated acid rain solution. Simultaneously, the corrosion products of Mg particles, magnesium oxides and phosphates, precipitated on the Mg particles and improved the stability of the primer. In addition, a protective film, consisting of magnesium oxides and phosphates, formed on the AZ91D substrate. Consequently, all these factors contributed to the long cathodic protection and improved corrosion resistance of MRP containing aluminum tri-polyphosphate in the simulated acid rain.
- 1 August 2019
- Published by Springer Nature in Journal of Wuhan University of Technology-Mater. Sci. Ed.
- Vol. 34 (4) , 906-913
Effect of Aluminum Tri-polyphosphate on Corrosion Behavior of Reinforcing Steel in Seawater Prepared Coral Concrete
- 1 August 2019
- Published by Springer Nature in Journal of Wuhan University of Technology-Mater. Sci. Ed.
- Vol. 34 (4) , 906-913
Effect of Aluminum Tri-polyphosphate on Corrosion Behavior of Reinforcing Steel in Seawater Prepared Coral Concrete
- 1 February 2016
- Published by Elsevier in Corrosion Science
- Vol. 103, 223-229
The effect of deformation on metastable pitting of 304 stainless steel in chloride contaminated concrete pore solution
- 1 February 2016
- Published by Elsevier in Corrosion Science
- Vol. 103, 223-229
The effect of deformation on metastable pitting of 304 stainless steel in chloride contaminated concrete pore solution