SSSteven Struhl

Steven Struhl

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Steven Struhl has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Needle Arthroscopy Demonstrates High Sensitivity and Specificity for Diagnosing Intra-Articular Shoulder and Knee Pathology

    by Brittany DeClouette, Amy Birnbaum, Hilary Campbell, Andrew S. Bi, Charles C. Lin, Steven Struhl

    Introduction: Needle arthroscopy has been introduced in recent years as an alternative to magnetic resonance imaging (MRI) for the evaluation of knee and shoulder conditions. It has continued to evolve at a rapid rate with newer generation models making in-office integration simple. As MRI can sometimes prove inconclusive, it is worthwhile to consider these alternative options for evaluating musculoskeletal pathology as a primary diagnostic tool. Purpose: The purpose of this study is to evaluate the specificity and sensitivity of needle arthroscopy in diagnosing intra-articular shoulder and knee pathology in a small case series of patients who ultimately underwent surgical arthroscopy. Methods: A retrospective, single-centre, single-surgeon, cohort study was performed over a three-year period from August 2018 to June 2021. During this time, diagnostic needle arthroscopy was performed on patients with suspected shoulder or knee pathology based on MRI findings and clinical exams. These patients subsequently underwent standard surgical arthroscopy. Results: Thirty-four patients were included in the study. There were 35 joints included, 25 shoulders and 10 knees, with a mean age of 41.88 +/- 11.32 years and BMI of 29.33 +/- 6.27 in the shoulder group and a mean age of 45.5 +/- 14.54 and BMI of 31.5 +/- 4.94 in the knee group. When evaluating shoulder pathologies, needle arthroscopy showed a sensitivity of 0.93 for rotator cuff tears, 1.00 for labral tears and 1.00 for loose bodies. Needle arthroscopy for the shoulder was found to be 100% specific for all shoulder pathologies. Needle arthroscopy for the knee was found to have a 1.00 sensitivity for detecting chondral defects and 0.80 sensitivity for meniscal tears. There were once again no false positive needle arthroscopy findings amongst the knee group. Conclusion: Needle arthroscopy is an accurate diagnostic tool for the evaluation of intra-articular knee and shoulder musculoskeletal pathology. It can provide a potential solution for MRI-derived diagnostic inaccuracies that can lead to missed pathologies or unindicated procedures. It is less invasive than surgical arthroscopy and should be considered a useful tool in the armamentarium of orthopedic surgeons.


  • Open Access

    Axial-Plane Biomechanical Evaluation of 2 Suspensory Cortical Button Fixation Constructs for Acromioclavicular Joint Reconstruction

    by Steven Struhl, Theodore S. Wolfson, Frederick Kummer

    Although numerous suture-button fixation techniques for acromioclavicular (AC) joint reconstruction have been validated with biomechanical testing in the superior direction, clinical reports continue to demonstrate high rates of construct slippage and breakage. To compare the stability of a novel closed-loop double Endobutton construct with a commercially available cortical button system in both the axial and superior directions. Controlled laboratory study. Six matched pairs of fresh-frozen cadaveric upper extremities were anatomically dissected and prepared to simulate a complete AC joint dislocation. One side of each pair was reconstructed with the double Endobutton (DE) construct and other side with the dog bone button (DB) construct. The specimens were then tested using a materials testing machine, determining initial superior and axial displacements with a preload, and then cyclically loaded in the axial direction with 70 N for 5000 cycles. Displacement was again measured with the same preloads at fixed cycle intervals. The specimens were then loaded superiorly to failure. At 5000 cycles, the mean axial displacement was 1.7 mm for the DB group and 1.2 mm for the DE group (P = .19), and the mean superior displacement was 1.1 mm for the DB group and 0.7 mm for the DE group (P = .32). Load at failure was similar (558 N for DE, 552 N for DB; P = .96). There was no statistically significant difference in the modes of failure. Biomechanical testing of both constructs showed similar fixation stability after cyclical axial loading and similar loads to failure. The strength of both constructs after cyclical loading in the axial plane and load-to-failure testing in the superior plane validate their continued clinical use for achieving stability in AC joint reconstruction procedures.


  • Open Access

    Closed-Loop Double Endobutton Technique for Repair of Unstable Distal Clavicle Fractures

    by Steven Struhl, Theodore S. Wolfson

    Background: Displaced fractures of the distal clavicle are inherently unstable and lead to nonunion in a high percentage of cases. The optimal surgical management remains controversial. Hypothesis: Indirect osteosynthesis with a closed-loop double endobutton construct would result in reliable fracture union and obviate the need for additional surgery. Study Design: Case series; Level of evidence, 4. Methods: Eight patients with an acute unstable Neer type IIB distal clavicle fracture were treated with a closed-loop double endobutton implant. Mean follow-up averaged 3.4 years (range, 1-9 years). Two patients were lost to follow-up. The remaining 6 patients underwent a detailed functional and radiologic evaluation. Results: Definitive fracture healing was achieved in all patients. There were no complications, and no patients required additional surgery related to the index procedure. The mean Constant score was 97 at final follow-up. Conclusion: The closed-loop double endobutton technique was reliable and effective in achieving fracture union in all patients with unstable Neer type IIB fractures of the distal clavicle. This technique obviates the need for late hardware removal that is often necessary when direct osteosynthesis is used and avoids potential complications associated with coracoclavicular cerclage constructs that require knot fixation.


  • Continuous Loop Double Endobutton Reconstruction for Acromioclavicular Joint Dislocation

    by Steven Struhl, Theodore S. Wolfson

    Background: Current anatomic methods for reconstruction of the dislocated acromioclavicular (AC) joint show improved clinical results but continue to be associated with significant rates of fixation loss and complications, limiting more widespread use. Purpose: To determine the long-term clinical and radiologic outcomes of a novel surgical technique using a closed-loop double Endobutton device to reconstruct both acute and chronic dislocations. Study Design: Case series; Level of evidence, 4. Methods: Between 2003 and 2012, a total of 35 patients (31 men, 4 women) at a mean age of 42 years (range, 25-70 years) were surgically treated for a Rockwood type III or greater AC joint dislocation with the described technique (26 chronic, 9 acute). Imbrication of the AC joint capsule and deltotrapezial fascia was performed in all patients. Biological bridging across the coracoclavicular (CC) interval was performed in all patients by use of coracoacromial (CA) ligament transfer in 28 patients and primary repair of the CC ligament in 7 patients. Complete follow-up information was obtained for 31 of 35 patients. Results: At a mean follow-up of 5.2 years (range, 27-144 months), the construct remained stable in all but 1 patient. The mean CC interval difference was 1.1 mm (range, –2.5 to 4.0 mm) and was Conclusion: Excellent results were obtained and maintained over long-term follow-up. The continuous loop device eliminated the possibility of knot slippage or breakage. MRI confirmed a robust healing response. The described technique resulted in outcomes that were significantly superior to historical reports of nonsurgical outcomes, and the technique can be recommended both for acute and chronic dislocations.