Rui Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rui Wang has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Lei Xu
Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing 100029, China
4 shared publications - Christian W. Hamm
Department of Medicine I, Cardiology and Angiology, University Hospital Giessen and Marburg, 35392 Giessen, Germany
1 shared publication - Daniel H. Steinberg
Medical University of South Carolina
1 shared publication - Felix Gabriel Meinel
Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Center Rostock, 18057 Rostock, Germany
1 shared publication - Helge Möllmann
Department of Cardiology, Kerckhoff Heart Center, Bad Nauheim, Germany
1 shared publication - Hongkai Zhang
Department of Radiology, Beijing Anzhen Hospital, Beijing Institute of Heart, Lung, and Blood Vessel Diseases, Capital Medical University, China
1 shared publication
Latest Publications
- Open Access
- 21 May 2026
- Published by Springer Nature in Pediatric Radiology
- Vol. 56 (7) , 1505-1515
Validation of a novel three-dimensional ultrafast cardiac magnetic resonance imaging protocol in adolescents: a non-inferiority study compared with the two-dimensional gold standard
Cardiac magnetic resonance (CMR) is the gold standard for assessing cardiac anatomy and function. However, long acquisition times and multiple breath-holds pose significant challenges in pediatric imaging. To perform a non-inferiority analysis comparing a novel 3-dimensional (D) ultrafast CMR protocol against the conventional 2-dimensional (D) gold standard for evaluating cardiac function, strain, and tissue characterization in adolescents. Thirty-nine adolescents (mean age 12.2±2.6 years) underwent both a standard 2-D protocol and a 3-D ultrafast protocol at 3-T. The 3-D protocol comprised enhanced sensitivity encoding by static outer volume subtraction (ESSOS) cine and 3-D late gadolinium enhancement. Image quality and diagnostic confidence were compared. A pre-specified non-inferiority margin (Δ) was used to assess functional and strain parameters. Agreement was evaluated using Bland-Altman analysis and intraclass correlation coefficients (ICCs). The total scan time was significantly shorter for the 3-D protocol compared to the 2-D protocol (75.8±10.0 s vs. 734.4±19.6 s, P<0.05). Image quality scores were comparable between protocols (median score 4.0, P=0.74). The 3-D protocol demonstrated statistical non-inferiority for all functional and strain metrics. Bland-Altman analysis showed minimal bias for key parameters, and the 95% confidence intervals for differences met the pre-specified non-inferiority margins. Intraclass correlation coefficients (ICCs) indicated good to excellent agreement for all parameters (n=39). The novel 3-D ultrafast CMR protocol is non-inferior to the conventional 2-D gold standard for quantitative assessment of cardiac function and strain in adolescents. It offers comparable image quality with significantly reduced acquisition times, potentially improving clinical feasibility in pediatric populations.
- 21 May 2026
- Published by Springer Nature in Pediatric Radiology
- Vol. 56 (7) , 1505-1515
Open AccessValidation of a novel three-dimensional ultrafast cardiac magnetic resonance imaging protocol in adolescents: a non-inferiority study compared with the two-dimensional gold standard
Cardiac magnetic resonance (CMR) is the gold standard for assessing cardiac anatomy and function. However, long acquisition times and multiple breath-holds pose significant challenges in pediatric imaging. To perform a non-inferiority analysis comparing a novel 3-dimensional (D) ultrafast CMR protocol against the conventional 2-dimensional (D) gold standard for evaluating cardiac function, strain, and tissue characterization in adolescents. Thirty-nine adolescents (mean age 12.2±2.6 years) underwent both a standard 2-D protocol and a 3-D ultrafast protocol at 3-T. The 3-D protocol comprised enhanced sensitivity encoding by static outer volume subtraction (ESSOS) cine and 3-D late gadolinium enhancement. Image quality and diagnostic confidence were compared. A pre-specified non-inferiority margin (Δ) was used to assess functional and strain parameters. Agreement was evaluated using Bland-Altman analysis and intraclass correlation coefficients (ICCs). The total scan time was significantly shorter for the 3-D protocol compared to the 2-D protocol (75.8±10.0 s vs. 734.4±19.6 s, P<0.05). Image quality scores were comparable between protocols (median score 4.0, P=0.74). The 3-D protocol demonstrated statistical non-inferiority for all functional and strain metrics. Bland-Altman analysis showed minimal bias for key parameters, and the 95% confidence intervals for differences met the pre-specified non-inferiority margins. Intraclass correlation coefficients (ICCs) indicated good to excellent agreement for all parameters (n=39). The novel 3-D ultrafast CMR protocol is non-inferior to the conventional 2-D gold standard for quantitative assessment of cardiac function and strain in adolescents. It offers comparable image quality with significantly reduced acquisition times, potentially improving clinical feasibility in pediatric populations.
- Open Access
- 9 March 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (6) , 2154
A Novel CT Perfusion-Based Fractional Flow Reserve Algorithm for Detecting Coronary Artery Disease
Background: The diagnostic accuracy of fractional flow reserve (FFR) derived from coronary computed tomography angiography (CCTA) (FFR-CT) needs to be further improved despite promising results available in the literature. While an innovative myocardial computed tomographic perfusion (CTP)-derived fractional flow reserve (CTP-FFR) model has been initially established, the feasibility of CTP-FFR to detect coronary artery ischemia in patients with suspected coronary artery disease (CAD) has not been proven. Methods: This retrospective study included 93 patients (a total of 103 vessels) who received CCTA and CTP for suspected CAD. Invasive coronary angiography (ICA) was performed within 2 weeks after CCTA and CTP. CTP-FFR, CCTA (stenosis ≥ 50% and ≥70%), ICA, FFR-CT and CTP were assessed by independent laboratory experts. The diagnostic ability of the CTP-FFR grouped by quantitative coronary angiography (QCA) in mild (30–49%), moderate (50–69%) and severe stenosis (≥70%) was calculated. The effect of calcification of lesions, grouped by FFR on CTP-FFR measurements, was also assessed. Results: On the basis of per-vessel level, the AUCs for CTP-FFR, CTP, FFR-CT and CCTA were 0.953, 0.876, 0.873 and 0.830, respectively (all p < 0.001). The sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) of CTP-FFR for per-vessel level were 0.87, 0.88, 0.87, 0.85 and 0.89 respectively, compared with 0.87, 0.54, 0.69, 0.61, 0.83 and 0.75, 0.73, 0.74, 0.70, 0.77 for CCTA ≥ 50% and ≥70% stenosis, respectively. On the basis of per-vessel analysis, CTP-FFR had higher specificity, accuracy and AUC compared with CCTA and also higher AUC compared with FFR-CT or CTP (all p < 0.05). The sensitivity and accuracy of CTP-FFR + CTP + FFR-CT were also improved over FFR-CT alone (both p < 0.05). It also had improved specificity compared with FFR-CT or CTP alone (p < 0.01). A strong correlation between CTP-FFR and invasive FFR values was found on per-vessel analysis (Pearson’s correlation coefficient 0.89). The specificity of CTP-FFR was higher in the severe calcification group than in the low calcification group (p < 0.001). Conclusions: A novel CTP-FFR model has promising value to detect myocardial ischemia in CAD, particularly in mild-to-moderate stenotic lesions.
- 9 March 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (6) , 2154
Open AccessA Novel CT Perfusion-Based Fractional Flow Reserve Algorithm for Detecting Coronary Artery Disease
Background: The diagnostic accuracy of fractional flow reserve (FFR) derived from coronary computed tomography angiography (CCTA) (FFR-CT) needs to be further improved despite promising results available in the literature. While an innovative myocardial computed tomographic perfusion (CTP)-derived fractional flow reserve (CTP-FFR) model has been initially established, the feasibility of CTP-FFR to detect coronary artery ischemia in patients with suspected coronary artery disease (CAD) has not been proven. Methods: This retrospective study included 93 patients (a total of 103 vessels) who received CCTA and CTP for suspected CAD. Invasive coronary angiography (ICA) was performed within 2 weeks after CCTA and CTP. CTP-FFR, CCTA (stenosis ≥ 50% and ≥70%), ICA, FFR-CT and CTP were assessed by independent laboratory experts. The diagnostic ability of the CTP-FFR grouped by quantitative coronary angiography (QCA) in mild (30–49%), moderate (50–69%) and severe stenosis (≥70%) was calculated. The effect of calcification of lesions, grouped by FFR on CTP-FFR measurements, was also assessed. Results: On the basis of per-vessel level, the AUCs for CTP-FFR, CTP, FFR-CT and CCTA were 0.953, 0.876, 0.873 and 0.830, respectively (all p < 0.001). The sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) of CTP-FFR for per-vessel level were 0.87, 0.88, 0.87, 0.85 and 0.89 respectively, compared with 0.87, 0.54, 0.69, 0.61, 0.83 and 0.75, 0.73, 0.74, 0.70, 0.77 for CCTA ≥ 50% and ≥70% stenosis, respectively. On the basis of per-vessel analysis, CTP-FFR had higher specificity, accuracy and AUC compared with CCTA and also higher AUC compared with FFR-CT or CTP (all p < 0.05). The sensitivity and accuracy of CTP-FFR + CTP + FFR-CT were also improved over FFR-CT alone (both p < 0.05). It also had improved specificity compared with FFR-CT or CTP alone (p < 0.01). A strong correlation between CTP-FFR and invasive FFR values was found on per-vessel analysis (Pearson’s correlation coefficient 0.89). The specificity of CTP-FFR was higher in the severe calcification group than in the low calcification group (p < 0.001). Conclusions: A novel CTP-FFR model has promising value to detect myocardial ischemia in CAD, particularly in mild-to-moderate stenotic lesions.
- Open Access
- 5 October 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (10) , 524
Development of Digital Fetal Heart Models with Virtual Ultrasound Function Based on Cardiovascular Casting and Computed Tomography Scan
Despite recent breakthroughs in diagnosis and treatment, congenital heart defects (CHDs) continue to be the leading cause of death among newborns. Fetal echocardiography is the most effective and non-invasive method for the prenatal diagnosis of CHDs. However, the challenge of obtaining standard views can lead to a low diagnostic accuracy. To explore new methods for training, the combined use of cardiovascular casting, computed tomography (CT) scanning, and virtual ultrasound generation methods was studied to preserve the cardiac structures of a fetus in digital form. The feasibility of the proposed workflow was verified by testing three fetal heart specimens collected after the termination of pregnancy. As a result, the anatomical structures were imaged clearly by a CT scan after cardiovascular casting, and the virtually generated ultrasound images based on the use of the Public software Library for UltraSound imaging research (PLUS) toolkit successfully demonstrated both the standard views and the views with diagnostic values for the visualization of the cardiovascular structures. This solution provides great data extensibility while being simple and cost-effective for end users. Therefore, the proposed method could provide a promising educational system for trainees to understand standard views of fetal echocardiography and the corresponding anatomical correlations.
- 5 October 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (10) , 524
Open AccessDevelopment of Digital Fetal Heart Models with Virtual Ultrasound Function Based on Cardiovascular Casting and Computed Tomography Scan
Despite recent breakthroughs in diagnosis and treatment, congenital heart defects (CHDs) continue to be the leading cause of death among newborns. Fetal echocardiography is the most effective and non-invasive method for the prenatal diagnosis of CHDs. However, the challenge of obtaining standard views can lead to a low diagnostic accuracy. To explore new methods for training, the combined use of cardiovascular casting, computed tomography (CT) scanning, and virtual ultrasound generation methods was studied to preserve the cardiac structures of a fetus in digital form. The feasibility of the proposed workflow was verified by testing three fetal heart specimens collected after the termination of pregnancy. As a result, the anatomical structures were imaged clearly by a CT scan after cardiovascular casting, and the virtually generated ultrasound images based on the use of the Public software Library for UltraSound imaging research (PLUS) toolkit successfully demonstrated both the standard views and the views with diagnostic values for the visualization of the cardiovascular structures. This solution provides great data extensibility while being simple and cost-effective for end users. Therefore, the proposed method could provide a promising educational system for trainees to understand standard views of fetal echocardiography and the corresponding anatomical correlations.
- 3 June 2021
- Published by Elsevier in International Journal of Cardiology
- Vol. 338, 276-277
Coronary computed tomography angiography radiomics: A potential noninvasive tool for detecting myocardial fibrosis
- 3 June 2021
- Published by Elsevier in International Journal of Cardiology
- Vol. 338, 276-277
Coronary computed tomography angiography radiomics: A potential noninvasive tool for detecting myocardial fibrosis