Stefano Cattaneo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Stefano Cattaneo has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Bradley Petkus
Swiss Center for Electronics and Microtechnology (CSEM), 7302 Landquart, Switzerland
2 shared publications - Hui Chai-Gao
Swiss Center for Electronics and Microtechnology (CSEM), 7302 Landquart, Switzerland
2 shared publications - Loïc Burr
Swiss Center for Electronics and Microtechnology (CSEM), 7302 Landquart, Switzerland
2 shared publications - Martti Kauranen
Tampere Univ. (Finland)
2 shared publications - Nicola Hermann
Swiss Center for Electronics and Microtechnology (CSEM), 7302 Landquart, Switzerland
2 shared publications - Patricia-Daiana Boia
Swiss Center for Electronics and Microtechnology (CSEM), 7302 Landquart, Switzerland
2 shared publications
Latest Publications
- Open Access
Point-of-Care Fluorescence Biosensing System for Rapid Multi-Allergen Screening
With the steady increase in allergy prevalence worldwide, there is a strong need for novel diagnostic tools for precise, fast, and less invasive testing methods. Herein, a miniatured fluorescence-based biosensing system is developed for the rapid and quantitative detection of allergen-specific immunoglobulin-E. An antibody-based fluorescence assay in a microfluidic-patterned slide, combined with a custom-made portable fluorescence reader for image acquisition and user-friendly software for the data analysis, enables obtaining results for multiple allergens in just ~1 h with only 80 μL of blood serum. The multiplexed detection of common birch, timothy grass, cat epithelia, house dust mite, and dog epithelia shows quantitative IgE-mediated allergic responses to specific allergens in control serum samples with known total IgE concentration. The responses are verified with different control tests and measurements with a commercial fluorescence reader. These results open the door to point-of-care allergy screening for early diagnosis and broader access and for large-scale research in allergies.
Open AccessPoint-of-Care Fluorescence Biosensing System for Rapid Multi-Allergen Screening
With the steady increase in allergy prevalence worldwide, there is a strong need for novel diagnostic tools for precise, fast, and less invasive testing methods. Herein, a miniatured fluorescence-based biosensing system is developed for the rapid and quantitative detection of allergen-specific immunoglobulin-E. An antibody-based fluorescence assay in a microfluidic-patterned slide, combined with a custom-made portable fluorescence reader for image acquisition and user-friendly software for the data analysis, enables obtaining results for multiple allergens in just ~1 h with only 80 μL of blood serum. The multiplexed detection of common birch, timothy grass, cat epithelia, house dust mite, and dog epithelia shows quantitative IgE-mediated allergic responses to specific allergens in control serum samples with known total IgE concentration. The responses are verified with different control tests and measurements with a commercial fluorescence reader. These results open the door to point-of-care allergy screening for early diagnosis and broader access and for large-scale research in allergies.
- Open Access
- 10 April 2024
- Published by MDPI AG in Proceedings
- Vol. 97 (1) , 173
Portable Fluorescence Biosensing System for Low-Cost, Quantitative, and Multiplexed Allergen Screening
A miniaturized multi-array system is being developed for immune-signature testing. The presented system includes microfluidic chips functionalized with allergens for IgE detection and a custom-made portable reader for fast (~1 s), quantitative, and sensitive (500 dye molecules/μm2) detection, with a high spatial resolution (~50–100 μm). The developed solution enables the rapid sensing of allergic reactions at the point of care with a low-cost portable device.
- 10 April 2024
- Published by MDPI AG in Proceedings
- Vol. 97 (1) , 173
Open AccessPortable Fluorescence Biosensing System for Low-Cost, Quantitative, and Multiplexed Allergen Screening
A miniaturized multi-array system is being developed for immune-signature testing. The presented system includes microfluidic chips functionalized with allergens for IgE detection and a custom-made portable reader for fast (~1 s), quantitative, and sensitive (500 dye molecules/μm2) detection, with a high spatial resolution (~50–100 μm). The developed solution enables the rapid sensing of allergic reactions at the point of care with a low-cost portable device.
- Open Access
- 22 July 2015
- Published by Frontiers Media SA in Frontiers in Chemistry
- Vol. 3, 45
Nanoparticle separation with a miniaturized asymmetrical flow field-flow fractionation cartridge
Asymmetrical Flow Field-Flow Fractionation (AF4) is a separation technique applicable to particles over a wide size range. Despite the many advantages of AF4, its adoption in routine particle analysis is somewhat limited by the large footprint of currently available separation cartridges, extended analysis times and significant solvent consumption. To address these issues, we describe the fabrication and characterization of miniaturized AF4 cartridges. Key features of the scale-down platform include simplified cartridge and reagent handling, reduced analysis costs and higher throughput capacities. The separation performance of the miniaturized cartridge is assessed using certified gold and silver nanoparticle standards. Analysis of gold nanoparticle populations indicates shorter analysis times and increased sensitivity compared to conventional AF4 separation schemes. Moreover, nanoparticulate titanium dioxide populations exhibiting broad size distributions are analyzed in a rapid and efficient manner. Finally, the repeatability and reproducibility of the miniaturized platform are investigated with respect to analysis time and separation efficiency.
- 22 July 2015
- Published by Frontiers Media SA in Frontiers in Chemistry
- Vol. 3, 45
Open AccessNanoparticle separation with a miniaturized asymmetrical flow field-flow fractionation cartridge
Asymmetrical Flow Field-Flow Fractionation (AF4) is a separation technique applicable to particles over a wide size range. Despite the many advantages of AF4, its adoption in routine particle analysis is somewhat limited by the large footprint of currently available separation cartridges, extended analysis times and significant solvent consumption. To address these issues, we describe the fabrication and characterization of miniaturized AF4 cartridges. Key features of the scale-down platform include simplified cartridge and reagent handling, reduced analysis costs and higher throughput capacities. The separation performance of the miniaturized cartridge is assessed using certified gold and silver nanoparticle standards. Analysis of gold nanoparticle populations indicates shorter analysis times and increased sensitivity compared to conventional AF4 separation schemes. Moreover, nanoparticulate titanium dioxide populations exhibiting broad size distributions are analyzed in a rapid and efficient manner. Finally, the repeatability and reproducibility of the miniaturized platform are investigated with respect to analysis time and separation efficiency.
- 1 July 2004
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 121 (1) , 1-4
A regression technique to analyze the second-order nonlinear optical response of thin films
We present a new technique, based on regression analysis, to determine the second-order nonlinear optical susceptibilitytensor of thin films. The technique does not require the absolute levels or phases of measured signals to be mutually calibrated. In addition it yields indicators that address the quality of theoretical models describing the sample. We use the technique to determine the susceptibilitytensor of samples of a nonracemic chiral material which have very low symmetry (both chiral and anisotropic) and have many independent tensor components. The results show the importance of using detailed theoretical models that account for the linear optical properties of the sample.
- 1 July 2004
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 121 (1) , 1-4
A regression technique to analyze the second-order nonlinear optical response of thin films
We present a new technique, based on regression analysis, to determine the second-order nonlinear optical susceptibilitytensor of thin films. The technique does not require the absolute levels or phases of measured signals to be mutually calibrated. In addition it yields indicators that address the quality of theoretical models describing the sample. We use the technique to determine the susceptibilitytensor of samples of a nonracemic chiral material which have very low symmetry (both chiral and anisotropic) and have many independent tensor components. The results show the importance of using detailed theoretical models that account for the linear optical properties of the sample.
- 15 August 2003
- Published by Optica Publishing Group in Optics Letters
- Vol. 28 (16) , 1445-1447
Determination of second-order susceptibility components of thin films by two-beam second-harmonic generation
We measure the susceptibility components of a poled polymer film by second-harmonic generation with two beams at the fundamental frequency. The technique allows the consistency of experimental data and the validity of the theoretical model used to analyze the results to be addressed. Our results are in agreement with the expected values, provided that the linear optical properties of the sample are properly included.
- 15 August 2003
- Published by Optica Publishing Group in Optics Letters
- Vol. 28 (16) , 1445-1447
Determination of second-order susceptibility components of thin films by two-beam second-harmonic generation
We measure the susceptibility components of a poled polymer film by second-harmonic generation with two beams at the fundamental frequency. The technique allows the consistency of experimental data and the validity of the theoretical model used to analyze the results to be addressed. Our results are in agreement with the expected values, provided that the linear optical properties of the sample are properly included.