IPIii Edward Padewski

Iii Edward Padewski

*This is an algorithmically generated author record based on publicly available information.

Iii Edward Padewski has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Sayreville Relief Force Main: 10 Years of Monitoring and Proactive Management

    by Edward A. Padewski, Donato J. Tanzi, Geanine Castaldi

    Proactive management, monitoring, and rehabilitation of pipelines are common phrases used in the water and wastewater industry today. Over the last 10 years, tools and techniques have rapidly evolved, providing utilities with a plethora of options for pipeline assessment and management. Because proactive management and monitoring are only recently being widely implemented across the industry, few long-term case studies documenting the success of these practices are available. This paper will discuss the monitoring and proactive management of the 102-inch Sayreville Relief Force Main, which has been actively monitored and routinely inspected for the last 10 years. When the Sayreville Relief Force Main experienced its second failure in March of 2003, many of the common techniques for condition assessment and asset management were just being introduced to the industry. Due to known deficiencies associated with Interpace PCCP manufactured in the 1970s, aggressive soils, and an environmentally sensitive surrounding area, the force main’s owner and operator, Middlesex County Utilities Authority (MCUA), began a program of inspection, assessment, and active monitoring. Over the 10-year management period, monitoring evolved from a surface-mounted sensor (SMS) system to an acoustic fiber optic (AFO) monitoring system, and the assessment techniques grew from visual and sounding inspections and electromagnetics to include sonic/ultrasonic testing, and advanced structural analysis. Through this program, MCUA has proactively rehabilitated deteriorating pipes, preventing catastrophic failures. A study of the evolution of the program for the Sayreville Relief Force Main can serve as a resource for other water and wastewater utilities, who will benefit from the lessons learned and the advantages gained over 10 years of proactive management.

  • Effects of the Location of Broken Prestressing Wire Wraps in Structural Integrity of a Damaged PCCP

    by Ali Alavinasab, Iii Edward Padewski, Mike Higgins

    Breakage of prestressing wire wraps is an indication of damage in Prestressed Concrete Cylinder Pipe (PCCP) due to corrosion, hydrogen embrittlement, overloading, and manufacturing defects. The strength of the damaged pipe is not only related to the number of broken prestressing wire wraps, but also to the location of the break regions along the length of the pipe. In this paper, a nonlinear Finite Element Method (FEM) was used to compare the structural integrity of a PCCP when wire wrap breaks occur at the spigot joint, the bell ring joint, and in the middle of the pipe section. For the structural evaluation, stresses and strains developed in the damaged PCCP were recorded and compared using the FEM computer modeling software, Abaqus. The Cracking and Ultimate Strength Limits, as defined in the American Water Works Association (AWWA) C304 Standard for Design of Prestressed Concrete Cylinder Pipe, of a damaged PCCP were investigated by increasing the internal pressure of the pipe while the severity of damage was manipulated by increasing the number of broken prestressing wire wraps. The results were obtained for a 60-inch embedded cylinder pipe (ECP) with 5, 35, 70, and 100 wire wrap breaks. The proposed model was applied to evaluate the effects of wire wrap breaks at the joints and in the middle of a pipe section. Based upon the obtained results, a comparison between wire break wrap in the middle of the pipe and the joint are presented and discussed.


  • Failure Risk of Bar-Wrapped Pipe with Broken Bars and Corroded Cylinder

    by Ali Alavinasab, Muthu Chandrasekaran, Iii Edward Padewski

    Bar-wrapped pipe ("BWP") commonly used in pressure pipelines due to its reliability, cost effectiveness and durability. Failure of BWP can occur as a result of long term leakage and subsequent corrosion or as a result of leakage and deterioration of the reinforcing bars over time. The failure can also be the direct result of a transient pressure or other sudden catastrophic events. The consequence of failure may result in a significant disruption of operation and service for a water utility without any warning. This is a concern because assessing the condition of a damaged BWP is very challenging. In this paper, a nonlinear finite element analysis was used to evaluate the performance of a damaged BWP. For the structural evaluation, stresses and strains developed in the damaged BWP were evaluated. Cracking and spalling of the mortar lining will eventually lead to the corrosion of the steel components. In an effort to account for the steel deterioration, the model was adjusted by reducing the thickness of the steel cylinder. This study investigates the behavior of a deteriorating BWP under various levels of distress and various internal pressures. The results based on a 24-inch pipe transmission main, are used to define criteria to evaluate the performance of a damaged BWP. Based upon the finite element results obtained in this study, suggestions for future work are presented and discussed.