Magdy T. Zaky
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Magdy T. Zaky has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Nermen H. Mohamed
Petroleum Refining Division, Egyptian Petroleum Research Institute (EPRI), Nasr City, Egypt
9 shared publications- Amal S. Farag
Petroleum Refining Division, Egyptian Petroleum Research Institute (EPRI), Nasr City, Egypt
8 shared publications - Fathi Samir Soliman
Egyptian Petroleum Research Institute
5 shared publications - Mohamed Abdel Moneim Deyab
Egyptian Petroleum Research Institute (EPRI), Nasr City, Cairo 11727, Egypt
3 shared publications - Ahmed M. A. El Naggar
Egyptian Petroleum Research Institute (EPRI), Nasr city, Egypt
2 shared publications Fathi S. Soliman
Petroleum Refining Division, Egyptian Petroleum Research Institute (EPRI), Nasr City, Egypt
2 shared publications
Latest Publications
- Open Access
- 1 April 2022
- Published by Egyptian Knowledge Bank in Arab Journal of Nuclear Sciences and Applications
- Vol. 55 (2) , 125-134
An Evaluation of the ETRR2’s Electrical Power System Short Circuit Study Using ETAP Software
Today, after more than twenty years of operation, the Egypt second research reactor (ETRR2’s) electrical power system needs to be re-evaluated in order to be sure that the system is still adequate for present situation of continuous operation under different circumstances, which may be severe in someinstances. In the process of revaluation of the ETRR2’s electrical power system, it is important to calculate the short circuit currents at several locationsin the system. For any electrical system, it is well known that determination of the short circuit current at different locations of the system is very important for two main reasons: first, selection of the short circuit rating for each equipment or switchboard and second, selection of the rating and setting for protective devices in the protection scheme. This work presents an analytical short circuit study of the ETRR2’s electrical power system by building its model using Electrical Transient and Analysis Program (ETAP software), which was not available during the ETRR2 design stage at the time. The built model was validated by comparing its simulation results with the designer calculation that was performed on limited points of the system. The authors take the advantages of this new advanced software to evaluate the system in every point we need in the system. Depending on the results of this study, it is feasible to decide which protective device or equipment that needs upgrading to be adequately rated for present operating circumstances. Also, the verified model can be used in future expansion,
- 1 April 2022
- Published by Egyptian Knowledge Bank in Arab Journal of Nuclear Sciences and Applications
- Vol. 55 (2) , 125-134
Open AccessAn Evaluation of the ETRR2’s Electrical Power System Short Circuit Study Using ETAP Software
Today, after more than twenty years of operation, the Egypt second research reactor (ETRR2’s) electrical power system needs to be re-evaluated in order to be sure that the system is still adequate for present situation of continuous operation under different circumstances, which may be severe in someinstances. In the process of revaluation of the ETRR2’s electrical power system, it is important to calculate the short circuit currents at several locationsin the system. For any electrical system, it is well known that determination of the short circuit current at different locations of the system is very important for two main reasons: first, selection of the short circuit rating for each equipment or switchboard and second, selection of the rating and setting for protective devices in the protection scheme. This work presents an analytical short circuit study of the ETRR2’s electrical power system by building its model using Electrical Transient and Analysis Program (ETAP software), which was not available during the ETRR2 design stage at the time. The built model was validated by comparing its simulation results with the designer calculation that was performed on limited points of the system. The authors take the advantages of this new advanced software to evaluate the system in every point we need in the system. Depending on the results of this study, it is feasible to decide which protective device or equipment that needs upgrading to be adequately rated for present operating circumstances. Also, the verified model can be used in future expansion,
- Open Access
- 16 November 2021
- Published by Egyptian Knowledge Bank in Arab Journal of Nuclear Sciences and Applications
- Vol. 55 (1) , 70-76
Calculation of dose rates in loss of coolant accident due to double ended rupture of the experimental tangential irradiation beam tube of MTR reactor.
A MTR reactor is an open water pool reactor type. The water pool serves as a shield from radioactive radiations. The most serious accident in this type of reactor is the Loss of Coolant Accident (LOCA) due to rupture either of a primary coolant pipe or of any experimental beam tube. In the present work it has been assumed that pool water drains out due to double ended rupture of the tangential irradiation beam tube (TIC) which has a diameter 150 mm. For an operating power level of 22 MW, the equilibrium core would enter into melting conditions if the pool drain time is less than one hour. It was also assumed that Emergency Core Cooling System (chimney water injection system and siphon effect breaker were not working. The reactor interiors have been modeled using the Monte Carlo N-Particle Transport code MCNPX 2.7.0. The source term has been determined using the ORIGEN-2 code. The doses and dose rates calculations in different places of operator (as phantom of Tissue-Equivalent Material) inside of the reactor building were determined by using Monte Carlo N-Particle Transport (MCNPX).The results show that the dose rate in the control room would be 5.24557 SV/h, the dose rate in the reactor hall above the pools on the gate would be7.20137 SV/h and the dose rate in the Emergency control room would be 2.68239 SV/h. Those dose rates are extremely high and would lead to fatal doses in short time.
- 16 November 2021
- Published by Egyptian Knowledge Bank in Arab Journal of Nuclear Sciences and Applications
- Vol. 55 (1) , 70-76
Open AccessCalculation of dose rates in loss of coolant accident due to double ended rupture of the experimental tangential irradiation beam tube of MTR reactor.
A MTR reactor is an open water pool reactor type. The water pool serves as a shield from radioactive radiations. The most serious accident in this type of reactor is the Loss of Coolant Accident (LOCA) due to rupture either of a primary coolant pipe or of any experimental beam tube. In the present work it has been assumed that pool water drains out due to double ended rupture of the tangential irradiation beam tube (TIC) which has a diameter 150 mm. For an operating power level of 22 MW, the equilibrium core would enter into melting conditions if the pool drain time is less than one hour. It was also assumed that Emergency Core Cooling System (chimney water injection system and siphon effect breaker were not working. The reactor interiors have been modeled using the Monte Carlo N-Particle Transport code MCNPX 2.7.0. The source term has been determined using the ORIGEN-2 code. The doses and dose rates calculations in different places of operator (as phantom of Tissue-Equivalent Material) inside of the reactor building were determined by using Monte Carlo N-Particle Transport (MCNPX).The results show that the dose rate in the control room would be 5.24557 SV/h, the dose rate in the reactor hall above the pools on the gate would be7.20137 SV/h and the dose rate in the Emergency control room would be 2.68239 SV/h. Those dose rates are extremely high and would lead to fatal doses in short time.
- 1 July 2020
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 310
Efficient pyridinium-based ionic liquid for deep oxidative desulfurization of model oil
- 1 July 2020
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 310
Efficient pyridinium-based ionic liquid for deep oxidative desulfurization of model oil
- 1 September 2019
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 290
Synthesis of new ionic liquids based on dicationic imidazolium and their anti-corrosion performances
- 1 September 2019
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 290
Synthesis of new ionic liquids based on dicationic imidazolium and their anti-corrosion performances
- 25 April 2019
- Published by Springer Nature in Catalysis Letters
- Vol. 149 (8) , 2119-2131
Pt/SAPO-11 Catalysts: Effect of Platinum Loading Method on the Hydroisomerization of n-Hexadecane
- 25 April 2019
- Published by Springer Nature in Catalysis Letters
- Vol. 149 (8) , 2119-2131
Pt/SAPO-11 Catalysts: Effect of Platinum Loading Method on the Hydroisomerization of n-Hexadecane
- 1 September 2018
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 266, 703-710
Three new gemini ionic liquids: Synthesis, characterizations and anticorrosion applications
- 1 September 2018
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 266, 703-710
Three new gemini ionic liquids: Synthesis, characterizations and anticorrosion applications
- 1 December 2017
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 248, 549-555
A coupled extractive-oxidative process for desulfurization of gasoline and diesel fuels using a bifunctional ionic liquid
- 1 December 2017
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 248, 549-555
A coupled extractive-oxidative process for desulfurization of gasoline and diesel fuels using a bifunctional ionic liquid
- 1 March 2017
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 229, 396-404
Inhibition of acid corrosion of carbon steel using four imidazolium tetrafluoroborates ionic liquids
- 1 March 2017
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 229, 396-404
Inhibition of acid corrosion of carbon steel using four imidazolium tetrafluoroborates ionic liquids