Julie N. Stewart
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Julie N. Stewart has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Rose Khavari
Department of Urology Houston Methodist Hospital Houston Texas USA
3 shared publications Danielle D. Antosh
1 shared publication- Ellen Fremion
Department of Internal Medicine, Baylor College of Medicine, Houston, TX, USA
1 shared publication - Jonathan Tolentino
University of Miami Miller School of Medicine
1 shared publication Julian Pacheco
1 shared publicationLia Miceli
1 shared publication
Latest Publications
- Open Access
- 5 November 2024
- Published by Elsevier in Continence
- Vol. 12
Intradetrusor OnabotulinumtoxinA outcomes for overactive bladder in older adults
- 5 November 2024
- Published by Elsevier in Continence
- Vol. 12
Open AccessIntradetrusor OnabotulinumtoxinA outcomes for overactive bladder in older adults
- 19 July 2024
- Published by Springer Nature
- p. 575-593
Spina Bifida
- 1 September 2015
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 137 (9) , 091007-0910077
The Single-Incision Sling to Treat Female Stress Urinary Incontinence: A Dynamic Computational Study of Outcomes and Risk Factors
Dynamic behaviors of the single-incision sling (SIS) to correct urethral hypermobility are investigated via dynamic biomechanical analysis using a computational model of the female pelvis, developed from a female subject's high-resolution magnetic resonance (MR) images. The urethral hypermobility is simulated by weakening the levator ani muscle in the pelvic model. Four positions along the posterior urethra (proximal, midproximal, middle, and mid-distal) were considered for sling implantation. The α-angle, urethral excursion angle, and sling–urethra interaction force generated during Valsalva maneuver were quantitatively characterized to evaluate the effect of the sling implantation position on treatment outcomes and potential complications. Results show concern for overcorrection with a sling implanted at the bladder neck, based on a relatively larger sling–urethra interaction force of 1.77 N at the proximal implantation position (compared with 0.25 N at mid-distal implantation position). A sling implanted at the mid-distal urethral location provided sufficient correction (urethral excursion angle of 23.8 deg after mid-distal sling implantation versus 24.4 deg in the intact case) with minimal risk of overtightening and represents the optimal choice for sling surgery. This study represents the first effort utilizing a comprehensive pelvic model to investigate the performance of an implanted sling to correct urethral hypermobility. The computational modeling approach presented in the study can also be used to advance presurgery planning, sling product design, and to enhance our understanding of various surgical risk factors which are difficult to obtain in clinical practice.
- 1 September 2015
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 137 (9) , 091007-0910077
The Single-Incision Sling to Treat Female Stress Urinary Incontinence: A Dynamic Computational Study of Outcomes and Risk Factors
Dynamic behaviors of the single-incision sling (SIS) to correct urethral hypermobility are investigated via dynamic biomechanical analysis using a computational model of the female pelvis, developed from a female subject's high-resolution magnetic resonance (MR) images. The urethral hypermobility is simulated by weakening the levator ani muscle in the pelvic model. Four positions along the posterior urethra (proximal, midproximal, middle, and mid-distal) were considered for sling implantation. The α-angle, urethral excursion angle, and sling–urethra interaction force generated during Valsalva maneuver were quantitatively characterized to evaluate the effect of the sling implantation position on treatment outcomes and potential complications. Results show concern for overcorrection with a sling implanted at the bladder neck, based on a relatively larger sling–urethra interaction force of 1.77 N at the proximal implantation position (compared with 0.25 N at mid-distal implantation position). A sling implanted at the mid-distal urethral location provided sufficient correction (urethral excursion angle of 23.8 deg after mid-distal sling implantation versus 24.4 deg in the intact case) with minimal risk of overtightening and represents the optimal choice for sling surgery. This study represents the first effort utilizing a comprehensive pelvic model to investigate the performance of an implanted sling to correct urethral hypermobility. The computational modeling approach presented in the study can also be used to advance presurgery planning, sling product design, and to enhance our understanding of various surgical risk factors which are difficult to obtain in clinical practice.