V. P. Mikhailov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
V. P. Mikhailov has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
A P Rotar’
Bauman Moscow State Technical University, 105005, Moscow, Russia
2 shared publicationsA. M. Bazinenkov
Bauman Moscow State Technical University
2 shared publications- Aleksey M. Bazinenkov
Bauman Moscow State Technical University
2 shared publications D A Ivanova
Bauman Moscow State Technical University, 105005, Moscow, Russia
2 shared publications- Evgueni A. Deulin
Bauman Moscow State Technical University, 105005, Moscow, Russia
2 shared publications A M Bazinenkov
Bauman Moscow State Technical University, 105005, Moscow, Russia
1 shared publication
Latest Publications
- Open Access
- 1 April 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 781 (1)
Actuator Based on a Dielectric Elastomer with Quartz as a Filler for Vacuum Technology
Modern equipment requires precise movement of objects both at atmospheric pressure and in vacuum conditions. Moreover, vacuum equipment is subjected to a number of external disturbances that adversely affect the manufacturing process and have a direct impact on the quality of manufactured products. A promising development in this area is actuators based on dielectric elastomers, characterized by a short reaction time (milliseconds) and a simple and cheap implementation. Successful implementation depends on an understanding of its behavior and properties, depending on the choice of matrix and filler materials. Most often, expensive barium titanate is used as a filler. This paper discusses the use of quartz as a cheaper filler.
- 1 April 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 781 (1)
Open AccessActuator Based on a Dielectric Elastomer with Quartz as a Filler for Vacuum Technology
Modern equipment requires precise movement of objects both at atmospheric pressure and in vacuum conditions. Moreover, vacuum equipment is subjected to a number of external disturbances that adversely affect the manufacturing process and have a direct impact on the quality of manufactured products. A promising development in this area is actuators based on dielectric elastomers, characterized by a short reaction time (milliseconds) and a simple and cheap implementation. Successful implementation depends on an understanding of its behavior and properties, depending on the choice of matrix and filler materials. Most often, expensive barium titanate is used as a filler. This paper discusses the use of quartz as a cheaper filler.
- Open Access
- 1 September 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1313 (1) , 012041
Active vibration isolation of high-vacuum nanotechnology equipment
The results of experimental studies of the transients’ parameters during the operation of a high-precision drive with a closed-loop control, which at the same time is an active damper, are presented. The amplitude-frequency characteristics of the damper and the vibration-isolating platform in semi-active mode based on four dampers and four elastic suspension assemblies are also shown.
- 1 September 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1313 (1) , 012041
Open AccessActive vibration isolation of high-vacuum nanotechnology equipment
The results of experimental studies of the transients’ parameters during the operation of a high-precision drive with a closed-loop control, which at the same time is an active damper, are presented. The amplitude-frequency characteristics of the damper and the vibration-isolating platform in semi-active mode based on four dampers and four elastic suspension assemblies are also shown.
- Open Access
- 1 September 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1313 (1) , 012005
Vacuum characteristics of magnetorheological elastomers
A model of gas evolution from the surface layer of a magnetorheological (MR) elastomer, which is a promising material for use in vacuum systems, is described. The results of research of the partial composition of gases exhaled from the MR elastomer for different heating temperatures depending on the pumping time are given.
- 1 September 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1313 (1) , 012005
Open AccessVacuum characteristics of magnetorheological elastomers
A model of gas evolution from the surface layer of a magnetorheological (MR) elastomer, which is a promising material for use in vacuum systems, is described. The results of research of the partial composition of gases exhaled from the MR elastomer for different heating temperatures depending on the pumping time are given.
- Open Access
- 17 July 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 387 (1) , 012016
System of vacuum mechanisms failure prediction based on outgassing flows dynamic
We simulated a vacuum system in order to diagnose vacuum mechanism failure with the goal of estimating dynamic properties of pumps (time to achieving desired pressure in the presence of rapidly varying flows, precision of dynamic pressure maintenance), determining maximum recordable impact frequency of rectangular gas flow pulses when detecting the mechanism state and predicting time to failure. The following parameters are usable for diagnostics: frequency and magnitude of outgassing flow oscillations in the mechanism, residual pressure fluctuations in the vacuum chamber.
- 17 July 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 387 (1) , 012016
Open AccessSystem of vacuum mechanisms failure prediction based on outgassing flows dynamic
We simulated a vacuum system in order to diagnose vacuum mechanism failure with the goal of estimating dynamic properties of pumps (time to achieving desired pressure in the presence of rapidly varying flows, precision of dynamic pressure maintenance), determining maximum recordable impact frequency of rectangular gas flow pulses when detecting the mechanism state and predicting time to failure. The following parameters are usable for diagnostics: frequency and magnitude of outgassing flow oscillations in the mechanism, residual pressure fluctuations in the vacuum chamber.
- 1 June 2018
- Published by Allerton Press in Russian Engineering Research
- Vol. 38 (6) , 434-437
Dynamic Modeling of an Active Damper
A dynamic model of the starting current of an active damper based on a magnetorheological elastomer is described, Experimental data for the damper are derived.
- 1 June 2018
- Published by Allerton Press in Russian Engineering Research
- Vol. 38 (6) , 434-437
Dynamic Modeling of an Active Damper
A dynamic model of the starting current of an active damper based on a magnetorheological elastomer is described, Experimental data for the damper are derived.
- Open Access
- 10 July 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 872 (1) , 012009
Linear motion feed through with thin wall rubber sealing element
The patented linear motion feedthrough is based on elastic thin rubber walls usage being reinforced with analeptic string fixed in the middle part of the walls. The pneumatic or hydro actuators create linear movement of stock. The length of this movement is two times more the rubber wall length. This flexible wall is a sealing element of feedthrough. The main advantage of device is negligible resistance force that is less then mentioned one in sealing bellows that leads to positioning error decreasing. Nevertheless, the thin wall rubber sealing element (TRE) of the feedthrough is the main unreliable element that was the reason of this element longevity research. The theory and experimental results help to create equation for TRE longevity calculation under vacuum or extra high pressure difference action. The equation was used for TRE longevity determination for hydraulic or vacuum equipment realization also as it helps for gas flow being leaking through the cracks in thin walls of rubber sealing element of linear motion feedthrough calculation.
- 10 July 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 872 (1) , 012009
Open AccessLinear motion feed through with thin wall rubber sealing element
The patented linear motion feedthrough is based on elastic thin rubber walls usage being reinforced with analeptic string fixed in the middle part of the walls. The pneumatic or hydro actuators create linear movement of stock. The length of this movement is two times more the rubber wall length. This flexible wall is a sealing element of feedthrough. The main advantage of device is negligible resistance force that is less then mentioned one in sealing bellows that leads to positioning error decreasing. Nevertheless, the thin wall rubber sealing element (TRE) of the feedthrough is the main unreliable element that was the reason of this element longevity research. The theory and experimental results help to create equation for TRE longevity calculation under vacuum or extra high pressure difference action. The equation was used for TRE longevity determination for hydraulic or vacuum equipment realization also as it helps for gas flow being leaking through the cracks in thin walls of rubber sealing element of linear motion feedthrough calculation.
- 1 July 2015
- Published by Allerton Press in Russian Engineering Research
- Vol. 35 (7) , 489-492
Active vibration-suppression platforms based on magnetorheological elastomers
A damper and platform for active vibration suppression based on magnetorheological elastomers are studied experimentally.
- 1 July 2015
- Published by Allerton Press in Russian Engineering Research
- Vol. 35 (7) , 489-492
Active vibration-suppression platforms based on magnetorheological elastomers
A damper and platform for active vibration suppression based on magnetorheological elastomers are studied experimentally.