Ming Chao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ming Chao has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Jose Penagaricano
University of Arkansas for Medical Sciences, Little Rock, AR
9 shared publications - Eduardo Gerardo Moros
Department of Radiation Oncology Moffitt Cancer Center Tampa Florida USA
7 shared publications P Corry
University of Arkansas for Medical Sciences, Little Rock, AR
5 shared publicationsV Ratanatharathorn
University of Arkansas for Medical Sciences, Little Rock, AR
5 shared publicationsYeh-Chi Lo
Department of Radiation Oncology, Icahn School of Medicine at Mount Sinai, The Mount Sinai Hospital, New York, NY, USA
5 shared publicationsJie Wei
The City College of New York, 160 Convent Ave, New York, New York, 10031-9101, UNITED STATES
4 shared publications
Latest Publications
- Open Access
- 3 July 2025
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 10 (8) , 101825
Impact of Normal Lung Volume Choices on Radiation Pneumonitis Risk Prediction in Locally Non-small Cell Lung Cancer Radiation Therapy
- 3 July 2025
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 10 (8) , 101825
Open AccessImpact of Normal Lung Volume Choices on Radiation Pneumonitis Risk Prediction in Locally Non-small Cell Lung Cancer Radiation Therapy
- 1 March 2025
- Published by Elsevier in Physica Medica
- Vol. 132, 104943
A feasibility study of lung tumor segmentation on kilo-voltage radiographic images with transfer learning: Toward tumor motion tracking in radiotherapy
- 1 March 2025
- Published by Elsevier in Physica Medica
- Vol. 132, 104943
A feasibility study of lung tumor segmentation on kilo-voltage radiographic images with transfer learning: Toward tumor motion tracking in radiotherapy
- 11 February 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (2) , 025030
Exploring spatial dose information in the parotid gland for xerostomia prediction and local dose patterns in head and neck cancer radiotherapy
Purpose. To investigate the relationship between spatial parotid dose and the risk of xerostomia in patients undergoing head-and-neck cancer radiotherapy, using machine learning (ML) methods. Methods. Prior to conducting voxel-based ML analysis of the spatial dose, two steps were taken: (1) The parotid dose was standardized through deformable image registration to a reference patient; (2) Bilateral parotid doses were regrouped into contralateral and ipsilateral portions depending on their proximity to the gross tumor target. Individual dose voxels were input into six commonly used ML models, which were tuned with ten-fold cross validation: random forest (RF), ridge regression (RR), support vector machine (SVM), extra trees (ET), k-nearest neighbor (kNN), and naïve Bayes (NB). Binary endpoints from 240 patients were used for model training and validation: 0 (N = 119) for xerostomia grades 0 or 1, and 1 (N = 121) for grades 2 or higher. Model performance was evaluated using multiple metrics, including accuracy, F1 score, areas under the receiver operating characteristics curves (auROC), and area under the precision–recall curves (auPRC). Dose voxel importance was assessed to identify local dose patterns associated with xerostomia risk. Results. Four models, including RF, SVM, ET, and NB, yielded average auROCs and auPRCs greater than 0.60 from ten-fold cross-validation on the training data, except for a lower auROC from NB. The first three models, along with kNN, demonstrated higher accuracy and F1 scores. A bootstrapping analysis confirmed test uncertainty. Voxel importance analysis from kNN indicated that the posterior portion of the ipsilateral gland was more predictive of xerostomia, but no clear patterns were identified from the other models. Conclusion. Voxel doses as predictors of xerostomia were confirmed with some ML classifiers, but no clear regional patterns could be established among these classifiers, except kNN. Further research with a larger patient dataset is needed to identify conclusive patterns.
- 11 February 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (2) , 025030
Exploring spatial dose information in the parotid gland for xerostomia prediction and local dose patterns in head and neck cancer radiotherapy
Purpose. To investigate the relationship between spatial parotid dose and the risk of xerostomia in patients undergoing head-and-neck cancer radiotherapy, using machine learning (ML) methods. Methods. Prior to conducting voxel-based ML analysis of the spatial dose, two steps were taken: (1) The parotid dose was standardized through deformable image registration to a reference patient; (2) Bilateral parotid doses were regrouped into contralateral and ipsilateral portions depending on their proximity to the gross tumor target. Individual dose voxels were input into six commonly used ML models, which were tuned with ten-fold cross validation: random forest (RF), ridge regression (RR), support vector machine (SVM), extra trees (ET), k-nearest neighbor (kNN), and naïve Bayes (NB). Binary endpoints from 240 patients were used for model training and validation: 0 (N = 119) for xerostomia grades 0 or 1, and 1 (N = 121) for grades 2 or higher. Model performance was evaluated using multiple metrics, including accuracy, F1 score, areas under the receiver operating characteristics curves (auROC), and area under the precision–recall curves (auPRC). Dose voxel importance was assessed to identify local dose patterns associated with xerostomia risk. Results. Four models, including RF, SVM, ET, and NB, yielded average auROCs and auPRCs greater than 0.60 from ten-fold cross-validation on the training data, except for a lower auROC from NB. The first three models, along with kNN, demonstrated higher accuracy and F1 scores. A bootstrapping analysis confirmed test uncertainty. Voxel importance analysis from kNN indicated that the posterior portion of the ipsilateral gland was more predictive of xerostomia, but no clear patterns were identified from the other models. Conclusion. Voxel doses as predictors of xerostomia were confirmed with some ML classifiers, but no clear regional patterns could be established among these classifiers, except kNN. Further research with a larger patient dataset is needed to identify conclusive patterns.
- Open Access
- 21 January 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (4) , e14620
Evaluation of AI‐based auto‐contouring tools in radiotherapy: A single‐institution study
Background: Accurate delineation of organs at risk (OARs) is crucial yet time‐consuming in the radiotherapy treatment planning workflow. Modern artificial intelligence (AI) technologies had made automation of OAR contouring feasible. This report details a single institution's experience in evaluating two commercial auto‐contouring software tools and making well‐informed decisions about their clinical adoption.Methods: A cohort of 36 patients previously treated at our institution were selected for the software performance assessment. Fifty‐eight OAR structures from seven disease sites were automatically segmented with each tool. Five radiation oncologists with different specialties qualitatively scored the automatic OAR contours’ clinical usability by a 4‐level scale (0–3), termed as quality score (QS), representing from “0: not usable” to “3: directly usable for a clinic.” Additionally, quantitative comparison with clinically approved contours using Dice similarity coefficient (DSC) and the 95% Hausdorff distance (HD95) was performed in complement to QS from physicians.Result: Software A achieved an average QS of 2.17 ± 0.69, comparable to Software B's average QS of 2.17 ± 0.72. Software B performed better with more OARs (42 vs. 37) that required minor or no modification than Software A. Major modifications were needed for 13 out of 58 automated contours from both tools. Both DSC and HD95 scores for the two tools were comparable to each other, with DSC: 0.67 ± 0.23 versus 0.66 ± 0.21 and HD95: 13.07 ± 15.84 versus 15.55 ± 18.45 for Software A and Software B, respectively. Correlation coefficients between the physician score and the quantitative metrics suggested that the contouring results from Software A aligned more closely with the physician's evaluations.Conclusion: Based on our study, either software tool could produce clinically acceptable contours for about 65% of the OAR structures. However, further refinement is necessary for several challenging OARs to improve model performance.
- 21 January 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (4) , e14620
Open AccessEvaluation of AI‐based auto‐contouring tools in radiotherapy: A single‐institution study
Background: Accurate delineation of organs at risk (OARs) is crucial yet time‐consuming in the radiotherapy treatment planning workflow. Modern artificial intelligence (AI) technologies had made automation of OAR contouring feasible. This report details a single institution's experience in evaluating two commercial auto‐contouring software tools and making well‐informed decisions about their clinical adoption.Methods: A cohort of 36 patients previously treated at our institution were selected for the software performance assessment. Fifty‐eight OAR structures from seven disease sites were automatically segmented with each tool. Five radiation oncologists with different specialties qualitatively scored the automatic OAR contours’ clinical usability by a 4‐level scale (0–3), termed as quality score (QS), representing from “0: not usable” to “3: directly usable for a clinic.” Additionally, quantitative comparison with clinically approved contours using Dice similarity coefficient (DSC) and the 95% Hausdorff distance (HD95) was performed in complement to QS from physicians.Result: Software A achieved an average QS of 2.17 ± 0.69, comparable to Software B's average QS of 2.17 ± 0.72. Software B performed better with more OARs (42 vs. 37) that required minor or no modification than Software A. Major modifications were needed for 13 out of 58 automated contours from both tools. Both DSC and HD95 scores for the two tools were comparable to each other, with DSC: 0.67 ± 0.23 versus 0.66 ± 0.21 and HD95: 13.07 ± 15.84 versus 15.55 ± 18.45 for Software A and Software B, respectively. Correlation coefficients between the physician score and the quantitative metrics suggested that the contouring results from Software A aligned more closely with the physician's evaluations.Conclusion: Based on our study, either software tool could produce clinically acceptable contours for about 65% of the OAR structures. However, further refinement is necessary for several challenging OARs to improve model performance.
- 9 January 2025
- Published by Elsevier in Clinical Oncology
- Vol. 39, 103758
Sex-Based Bias in Artificial Intelligence-Based Segmentation Models in Clinical Oncology
- 9 January 2025
- Published by Elsevier in Clinical Oncology
- Vol. 39, 103758
Sex-Based Bias in Artificial Intelligence-Based Segmentation Models in Clinical Oncology
- 1 November 2023
- Published by American Society of Clinical Oncology (ASCO) in JCO Oncology Practice
- Vol. 19 (11_suppl) , 255
Can we skip the simulation step for radiation treatment planning in patients with symptomatic bone metastases?
- 1 November 2023
- Published by American Society of Clinical Oncology (ASCO) in JCO Oncology Practice
- Vol. 19 (11_suppl) , 255
Can we skip the simulation step for radiation treatment planning in patients with symptomatic bone metastases?
- 9 May 2022
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 61 (7) , 842-848
Cluster model incorporating heterogeneous dose distribution of partial parotid irradiation for radiotherapy induced xerostomia prediction with machine learning methods
A cluster model incorporating heterogeneous dose distribution within the parotid gland was developed and validated retrospectively for radiotherapy (RT) induced xerostomia prediction with machine l...
- 9 May 2022
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 61 (7) , 842-848
Cluster model incorporating heterogeneous dose distribution of partial parotid irradiation for radiotherapy induced xerostomia prediction with machine learning methods
A cluster model incorporating heterogeneous dose distribution within the parotid gland was developed and validated retrospectively for radiotherapy (RT) induced xerostomia prediction with machine l...
- 2 December 2019
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 43 (1) , 143-153
Dose cluster model parameterization of the parotid gland in irradiation of head and neck cancer
To explore the parotid normal tissue complication probability (NTCP) modeling with percolation-based dose clusters for head-and-neck patients receiving concomitant chemotherapy and radiation therapy. Cluster models incorporating the spatial dose distribution in the parotid gland were developed to evaluate the radiation induced complication. Cluster metrics including the mean cluster size (NMCS) and the largest cluster size both normalized by the gland volume (NSLC) were evaluated and scrutinized against the benchmark NTCP. Two fitting strategies to the Lyman–Kutcher–Burman (LKB) model using the maximum likelihood method were devised: the volume parameter n fixed at 1.0 (mean dose model) and unrestricted (full LKB model). The fitted parameters TD50 and m were assessed with the LKB NTCP models with the available xerostomia data. NSLC was a better metric than NMCS with reference to the LKB model and strong correlation (r ~ 0.95) was observed between NTCP and NSLC. The mean dose model returned the parameter TD50 (39.9 Gy) and m (0.4) from the NSLC of threshold dose at around 40 Gy. Drastically different TD50 and m values were obtained from the fittings via the full LKB model, where the threshold dose would be near 27 Gy. Bootstrapping analyses further confirmed the fitting outcomes. Strong correlation with the traditional NTCP models revealed that the cluster model could achieve what NTCP models attain and may offer additional information. Parameterization of the model indicated that the model could have different predictions from current clinical recommendations. Further investigation using toxicity data is under way to validate the cluster model.
- 2 December 2019
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 43 (1) , 143-153
Dose cluster model parameterization of the parotid gland in irradiation of head and neck cancer
To explore the parotid normal tissue complication probability (NTCP) modeling with percolation-based dose clusters for head-and-neck patients receiving concomitant chemotherapy and radiation therapy. Cluster models incorporating the spatial dose distribution in the parotid gland were developed to evaluate the radiation induced complication. Cluster metrics including the mean cluster size (NMCS) and the largest cluster size both normalized by the gland volume (NSLC) were evaluated and scrutinized against the benchmark NTCP. Two fitting strategies to the Lyman–Kutcher–Burman (LKB) model using the maximum likelihood method were devised: the volume parameter n fixed at 1.0 (mean dose model) and unrestricted (full LKB model). The fitted parameters TD50 and m were assessed with the LKB NTCP models with the available xerostomia data. NSLC was a better metric than NMCS with reference to the LKB model and strong correlation (r ~ 0.95) was observed between NTCP and NSLC. The mean dose model returned the parameter TD50 (39.9 Gy) and m (0.4) from the NSLC of threshold dose at around 40 Gy. Drastically different TD50 and m values were obtained from the fittings via the full LKB model, where the threshold dose would be near 27 Gy. Bootstrapping analyses further confirmed the fitting outcomes. Strong correlation with the traditional NTCP models revealed that the cluster model could achieve what NTCP models attain and may offer additional information. Parameterization of the model indicated that the model could have different predictions from current clinical recommendations. Further investigation using toxicity data is under way to validate the cluster model.
- 1 May 2018
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 127 (2) , 197-205
Three-dimensional cluster formation and structure in heterogeneous dose distribution of intensity modulated radiation therapy
- 1 May 2018
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 127 (2) , 197-205
Three-dimensional cluster formation and structure in heterogeneous dose distribution of intensity modulated radiation therapy
- 1 February 2018
- Published by Elsevier in Physica Medica
- Vol. 46, 7-15
A constrained linear regression optimization algorithm for diaphragm motion tracking with cone beam CT projections
- 1 February 2018
- Published by Elsevier in Physica Medica
- Vol. 46, 7-15
A constrained linear regression optimization algorithm for diaphragm motion tracking with cone beam CT projections