Longyu Kuang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Longyu Kuang has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
Longfei Jing
National Key Laboratory of Plasma Physics, Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, Sichuan 621900, China
6 shared publicationsZhiwei Lin
National Key Laboratory of Plasma Physics, Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, Sichuan 621900, China
5 shared publicationsHang Li
Research Center of Laser Fusion China Academy of Engineering Physics 621900 Mianyang China
4 shared publicationsJiamin Yang
National Key Laboratory of Plasma Physics, Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, Sichuan 621900, China
4 shared publicationsJianhua Zheng
Research Center of Laser Fusion China Academy of Engineering Physics 621900 Mianyang China
4 shared publicationsLu Zhang
Research Center of Laser Fusion China Academy of Engineering Physics 621900 Mianyang China
4 shared publications
Latest Publications
- Open Access
- 15 April 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (6)
Precise hohlraum X-ray flux predictions at the 100 kJ-level laser facility with deep learning
Precise prediction of the hohlraum X-ray drive is essential for target design optimization in indirect-drive inertial confinement fusion (ICF). Conventional simulations, however, are often hampered by the hohlraum drive deficit, which limits their predictive power for new experimental configurations. This study focuses on the two shock implosions of the 100 kJ-level laser facility, aiming to precisely infer radiation source calibrated by multiple diagnostics. A joint inversion method for the radiation source and M-band power multipliers was developed, leading to the construction of a surrogate model that maps experimental design parameters to radiation source waveforms. Based on this model, a deep learning inference framework, PRISM, was established to achieve precise radiation source prediction. The model exhibits excellent predictive accuracy and provides an efficient method for pre-shot simulations. Its extrapolation capability was validated using transmission grating spectrometer data, demonstrating high consistency between simulated and measured spectra. Shapley Additive Explanations revealed the relative contributions of experimental design parameters to each multiplier. Finally, we used residual-based analysis to quantify engineering accuracy. The analysis indicates significantly improved engineering control of the 100 kJ-level laser facility in 2025, particularly in laser output stability, although pulse synchronization and delays remain areas for refinement.
- 15 April 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (6)
Open AccessPrecise hohlraum X-ray flux predictions at the 100 kJ-level laser facility with deep learning
Precise prediction of the hohlraum X-ray drive is essential for target design optimization in indirect-drive inertial confinement fusion (ICF). Conventional simulations, however, are often hampered by the hohlraum drive deficit, which limits their predictive power for new experimental configurations. This study focuses on the two shock implosions of the 100 kJ-level laser facility, aiming to precisely infer radiation source calibrated by multiple diagnostics. A joint inversion method for the radiation source and M-band power multipliers was developed, leading to the construction of a surrogate model that maps experimental design parameters to radiation source waveforms. Based on this model, a deep learning inference framework, PRISM, was established to achieve precise radiation source prediction. The model exhibits excellent predictive accuracy and provides an efficient method for pre-shot simulations. Its extrapolation capability was validated using transmission grating spectrometer data, demonstrating high consistency between simulated and measured spectra. Shapley Additive Explanations revealed the relative contributions of experimental design parameters to each multiplier. Finally, we used residual-based analysis to quantify engineering accuracy. The analysis indicates significantly improved engineering control of the 100 kJ-level laser facility in 2025, particularly in laser output stability, although pulse synchronization and delays remain areas for refinement.
- 31 March 2025
- Published by Springer Nature in The European Physical Journal Special Topics
- Vol. 234 (4) , 829-836
Measurement of megagauss pulsed magnetic field of a planar target by B-dot probe on the Shenguang-II high-power laser facility
- 31 March 2025
- Published by Springer Nature in The European Physical Journal Special Topics
- Vol. 234 (4) , 829-836
Measurement of megagauss pulsed magnetic field of a planar target by B-dot probe on the Shenguang-II high-power laser facility
- Open Access
Laboratorial radiative shocks with multiple parameters and first quantifying verifications to core-collapse supernovae
We present experiments to reproduce the characteristics of core-collapse supernovae with different stellar masses and initial explosion energies in the laboratory. In the experiments, shocks are driven in 1.2 atm and 1.9 atm xenon gas by laser with energy from 1600J to 2800J on the SGIII prototype laser facility. The average shock velocities and shocked densities are obtained from experiments. Experimental results reveal that higher laser energy and lower Xe gas density led to higher shock velocity, and lower Xe gas initial density has a higher compression. Modeling of the experiments using the 2D radiation hydrodynamic codes Icefire shows excellent agreement with the experimental results and gives the temperature. These results will contribute to time-domain astrophysical systems, such as gravitational supernovae, where a strong radiative shock propagates outward from the center of the star after the core collapses.
Open AccessLaboratorial radiative shocks with multiple parameters and first quantifying verifications to core-collapse supernovae
We present experiments to reproduce the characteristics of core-collapse supernovae with different stellar masses and initial explosion energies in the laboratory. In the experiments, shocks are driven in 1.2 atm and 1.9 atm xenon gas by laser with energy from 1600J to 2800J on the SGIII prototype laser facility. The average shock velocities and shocked densities are obtained from experiments. Experimental results reveal that higher laser energy and lower Xe gas density led to higher shock velocity, and lower Xe gas initial density has a higher compression. Modeling of the experiments using the 2D radiation hydrodynamic codes Icefire shows excellent agreement with the experimental results and gives the temperature. These results will contribute to time-domain astrophysical systems, such as gravitational supernovae, where a strong radiative shock propagates outward from the center of the star after the core collapses.
- Open Access
- 30 August 2022
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 64 (10) , 105022
Study of the radiation temperature on ablator by using the shock wave technique
A new diagnostic platform for more accurate diagnosis of the peak radiation temperature on ablator has been proposed. A nearly constant radiation temperature was obtained by two laser entrance holes spherical hohlraum. The peak radiation temperature on ablator was determined by the shock wave technique. A high-quality burn-through image of a two-step-shaped Au ablator was obtained in the experiment. The simulated mass ablation rate agrees well with the experimental result, while the peak radiation temperature measured by flat-response x-ray detectors outside the hohlraum was of ∼20 eV’s lower than that obtained by the shock wave technique. This deviation results in ∼20%’s decrease in the mass ablation rate in the simulation. Thus, the new diagnostic platform can provide more accurate peak radiation temperature diagnosis. This can greatly support the inertial confinement fusion ignition target design.
- 30 August 2022
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 64 (10) , 105022
Open AccessStudy of the radiation temperature on ablator by using the shock wave technique
A new diagnostic platform for more accurate diagnosis of the peak radiation temperature on ablator has been proposed. A nearly constant radiation temperature was obtained by two laser entrance holes spherical hohlraum. The peak radiation temperature on ablator was determined by the shock wave technique. A high-quality burn-through image of a two-step-shaped Au ablator was obtained in the experiment. The simulated mass ablation rate agrees well with the experimental result, while the peak radiation temperature measured by flat-response x-ray detectors outside the hohlraum was of ∼20 eV’s lower than that obtained by the shock wave technique. This deviation results in ∼20%’s decrease in the mass ablation rate in the simulation. Thus, the new diagnostic platform can provide more accurate peak radiation temperature diagnosis. This can greatly support the inertial confinement fusion ignition target design.
- 20 September 2021
- Published by IOP Publishing in Nuclear Fusion
- Vol. 61 (12) , 126023
Optimization of tungsten-doped high density carbon target in inertial confinement fusion
Tungsten(W)-doped high density carbon(HDC) target is a promising design for ignition target in inertial confinement fusion (ICF). The influence of silicon(Si) and tungsten(W) on transmission of M-band X-ray has been studied by experiment. With a radiation temperature of ∼ 200eV , the transmitted M-band X-ray(1.6-4.4keV) flux and spectrum of Si or W-buried HDC sample were measured by M-XRDs and TGS, respectively. The thin layer of Si or W was buried at two different depths(2.1µm and 11µm). Results show that M-band transmission flux of Si-buried HDC sample decreases with buried depth(bd). However bd does not influence that of W-buried HDC sample. The one-dimensional simulation result is consistent with the experimental result. In the 1D simulation, the Au M-band(2-5keV) transmission flux of Si-buried HDC also decreases with bd. However Au M-band transmission flux of W-buried HDC increases at first and then decreases. This is mainly due to the different characteristics of Si and W opacity. Especially as the peak radiation temperature reaches 260eV, W can still absorb the M-band X-ray efficiently as it is buried near the radiation source. Based on these studies, optimized W-doped HDC target with low doped fraction and mass has been proposed in this paper.
- 20 September 2021
- Published by IOP Publishing in Nuclear Fusion
- Vol. 61 (12) , 126023
Optimization of tungsten-doped high density carbon target in inertial confinement fusion
Tungsten(W)-doped high density carbon(HDC) target is a promising design for ignition target in inertial confinement fusion (ICF). The influence of silicon(Si) and tungsten(W) on transmission of M-band X-ray has been studied by experiment. With a radiation temperature of ∼ 200eV , the transmitted M-band X-ray(1.6-4.4keV) flux and spectrum of Si or W-buried HDC sample were measured by M-XRDs and TGS, respectively. The thin layer of Si or W was buried at two different depths(2.1µm and 11µm). Results show that M-band transmission flux of Si-buried HDC sample decreases with buried depth(bd). However bd does not influence that of W-buried HDC sample. The one-dimensional simulation result is consistent with the experimental result. In the 1D simulation, the Au M-band(2-5keV) transmission flux of Si-buried HDC also decreases with bd. However Au M-band transmission flux of W-buried HDC increases at first and then decreases. This is mainly due to the different characteristics of Si and W opacity. Especially as the peak radiation temperature reaches 260eV, W can still absorb the M-band X-ray efficiently as it is buried near the radiation source. Based on these studies, optimized W-doped HDC target with low doped fraction and mass has been proposed in this paper.
- Open Access
An advanced three-axis elliptical hohlraum for indirectly driven inertial confinement fusion
The radiation symmetry and laser-plasma instabilities (LPIs) inside the conventional cylindrical hohlraum configuration are the two daunting challenges on the approach to ignition in indirectly driven inertial confinement fusion. Recently, near-vacuum cylindrical hohlraum (NVCH), octahedral spherical hohlraum (SH) and novel three-axis cylindrical hohlraum (TACH) were proposed to mitigate these issues. While the coupling efficiency might still be a critical risk. In this paper, an advanced three-axis elliptical hohlraum (TAEH) is proposed to make a compromise among these hohlraum performance. Preliminary simulations indicate that the TAEH (with a case-to-capsule ratio, CCR=2.8) could provide excellent radiation symmetry during the thorough laser pulse of the high-foot drive, comparable to the ones inside the SH (CCR=5.1) and TACH (CCR=2.2). The filling time of plasma affecting the LPIs is between those of SH and TACH, and about 1.5 times of that in the ignition hohlraum Rev5-CH of NIC and close to the one inside the NVCH (CCR=3.4). In particular, the coupling efficiency is about 22%, 29% and 17% higher than the one inside the NVCH, SH and TACH, respectively. It would be envisioned that the proposed hohlraum configuration merits consideration as an alternative route to indirect-drive ignition, complementary to the traditional cylindrical hohlraum and the proposed recently novel hohlraums.
Open AccessAn advanced three-axis elliptical hohlraum for indirectly driven inertial confinement fusion
The radiation symmetry and laser-plasma instabilities (LPIs) inside the conventional cylindrical hohlraum configuration are the two daunting challenges on the approach to ignition in indirectly driven inertial confinement fusion. Recently, near-vacuum cylindrical hohlraum (NVCH), octahedral spherical hohlraum (SH) and novel three-axis cylindrical hohlraum (TACH) were proposed to mitigate these issues. While the coupling efficiency might still be a critical risk. In this paper, an advanced three-axis elliptical hohlraum (TAEH) is proposed to make a compromise among these hohlraum performance. Preliminary simulations indicate that the TAEH (with a case-to-capsule ratio, CCR=2.8) could provide excellent radiation symmetry during the thorough laser pulse of the high-foot drive, comparable to the ones inside the SH (CCR=5.1) and TACH (CCR=2.2). The filling time of plasma affecting the LPIs is between those of SH and TACH, and about 1.5 times of that in the ignition hohlraum Rev5-CH of NIC and close to the one inside the NVCH (CCR=3.4). In particular, the coupling efficiency is about 22%, 29% and 17% higher than the one inside the NVCH, SH and TACH, respectively. It would be envisioned that the proposed hohlraum configuration merits consideration as an alternative route to indirect-drive ignition, complementary to the traditional cylindrical hohlraum and the proposed recently novel hohlraums.
- 1 January 2016
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 65 (1) , 015202
Experimental study on improving hohlraum wall reemission ratio by low density gold foam
It is important to improve the hohlraum radiation temperature for the research of high energy density physics, especially for study of inertial confinement fusion. Increasing the wall reemission ratio is an effective way to improve the temperature. It is found in theory that low density foam could reduce hohlraum wall energy loss, and then increase hohlraum temperature. In previous studies, experiments have shown that laser-to-X-ray conversion is enhanced by Au foam. However, improving reemission ratio is more important to increase hohlraum radiation temperature, because most of energy is lost in the wall.In this paper, we report our experiments carried out on SGⅢ prototype to compare the X-ray flux reemitted by Au foam and that by Au. For the experimental design, Au solid and Au foam are irradiated symmetrically along the axis by hohlraum radiation source Tr(t), which is assessed by broadband X-ray spectrometer flat-response X-ray diodes. The measured peak temperature is about 190 eV. Reemission flux from sample is measured by transmission grating spectrometer (TGS). The space-resolved image for pure Au sample shows that the hohlraum radiation is asymmetrical along the axis in the experimental conditions, temperature of top is higher than that at the bottom, which is consistent with simulation results obtained by using IRAD3D code. In order to compare the reemission flux from Au solid sample and that from Au foam sample in same conditions, we need to correct the symmetry of hohlraum radiation. By multiplying the ratio of top flux to bottom flux in pure Au target by the bottom flux in Au-Au foam target, where Au foam is on, we make sure that they are ablated by the same radiation source. The calculated results show that X-ray flux is increased by 20% by Au foam of 0.4 g/cc density when the hohlraum temperature is 190 eV. The typical observed time-integrated X-ray reemission spectra for Au solid and Au foam by TGS are also shown. We see that N-band and O-band reemission are clearly enhanced by Au foam, and the O-band reemission is almost the same as M-band reemission. The increased flux concentrates below 1 keV of the soft X-ray emission.The self-similar solution results and MULTI 1D simulation results show that the wall loss energy fraction is saved by Au foam, whose relation to reemission flux can be described by a simple expression. The theoretical solution shows that the emission flux increases about 10%, and the MULTI simulation indicates that the emission flux increases about 6.8%. They are in qualitative agreement with the experiments results. These results show an alluring prospect for Au foam to be used as hohlraum wall.
- 1 January 2016
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 65 (1) , 015202
Experimental study on improving hohlraum wall reemission ratio by low density gold foam
It is important to improve the hohlraum radiation temperature for the research of high energy density physics, especially for study of inertial confinement fusion. Increasing the wall reemission ratio is an effective way to improve the temperature. It is found in theory that low density foam could reduce hohlraum wall energy loss, and then increase hohlraum temperature. In previous studies, experiments have shown that laser-to-X-ray conversion is enhanced by Au foam. However, improving reemission ratio is more important to increase hohlraum radiation temperature, because most of energy is lost in the wall.In this paper, we report our experiments carried out on SGⅢ prototype to compare the X-ray flux reemitted by Au foam and that by Au. For the experimental design, Au solid and Au foam are irradiated symmetrically along the axis by hohlraum radiation source Tr(t), which is assessed by broadband X-ray spectrometer flat-response X-ray diodes. The measured peak temperature is about 190 eV. Reemission flux from sample is measured by transmission grating spectrometer (TGS). The space-resolved image for pure Au sample shows that the hohlraum radiation is asymmetrical along the axis in the experimental conditions, temperature of top is higher than that at the bottom, which is consistent with simulation results obtained by using IRAD3D code. In order to compare the reemission flux from Au solid sample and that from Au foam sample in same conditions, we need to correct the symmetry of hohlraum radiation. By multiplying the ratio of top flux to bottom flux in pure Au target by the bottom flux in Au-Au foam target, where Au foam is on, we make sure that they are ablated by the same radiation source. The calculated results show that X-ray flux is increased by 20% by Au foam of 0.4 g/cc density when the hohlraum temperature is 190 eV. The typical observed time-integrated X-ray reemission spectra for Au solid and Au foam by TGS are also shown. We see that N-band and O-band reemission are clearly enhanced by Au foam, and the O-band reemission is almost the same as M-band reemission. The increased flux concentrates below 1 keV of the soft X-ray emission.The self-similar solution results and MULTI 1D simulation results show that the wall loss energy fraction is saved by Au foam, whose relation to reemission flux can be described by a simple expression. The theoretical solution shows that the emission flux increases about 10%, and the MULTI simulation indicates that the emission flux increases about 6.8%. They are in qualitative agreement with the experiments results. These results show an alluring prospect for Au foam to be used as hohlraum wall.
- 18 August 2015
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 63 (3) , 261-268
Characterization of a quasi-sinusoidal transmission grating without membrane substrate in the 200–1500 eV photon energy regions
A 1000-line/mm quasi-sinusoidal transmission grating (QSTG) without membrane substrate has been designed and fabricated, which is utilized to eliminate the higher order diffraction for soft X-ray spectrum measurement in the experiments of inertial confinement fusion. The grating was calibrated using an X-ray beam on synchrotron radiation facility. It shows that the QSTG has the desired diffraction property and the higher order diffraction components are efficiently suppressed in the photon energy ranges from 200 to 1500 eV.
- 18 August 2015
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 63 (3) , 261-268
Characterization of a quasi-sinusoidal transmission grating without membrane substrate in the 200–1500 eV photon energy regions
A 1000-line/mm quasi-sinusoidal transmission grating (QSTG) without membrane substrate has been designed and fabricated, which is utilized to eliminate the higher order diffraction for soft X-ray spectrum measurement in the experiments of inertial confinement fusion. The grating was calibrated using an X-ray beam on synchrotron radiation facility. It shows that the QSTG has the desired diffraction property and the higher order diffraction components are efficiently suppressed in the photon energy ranges from 200 to 1500 eV.