Yonghua Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yonghua Yu has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Jin-Ming Yu
Shandong Cancer Hospital and Institute, Jinan, China
4 shared publications Zheng Fu
Department of Nuclear Medicine, Shandong Tumor Hospital and Institute, Jinan, Shandong 250117, P.R. China
4 shared publicationsYong Zhang
Department of Radiation Oncology, Shandong Tumor Hospital and Institute, Jinan, Shandong 250117, P.R. China
3 shared publications- Shuanghu Yuan
Department of Radiation Oncology, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui Province, China
2 shared publications Tonghai Liu
Department of Imaging Physics, Shandong Tumor Hospital and Institute, Jinan, Shandong 250117, P.R. China
2 shared publicationsYong Yin
Department of Medical Physics, Shandong Cancer Hospital and Institute, Ji'nan, China
2 shared publications
Latest Publications
- Open Access
- 25 August 2015
- Published by Spandidos Publications in Oncology Letters
- Vol. 10 (5) , 2909-2914
18FDG PET-CT standardized uptake value for the prediction of radiation pneumonitis in patients with lung cancer receiving radiotherapy
The present study aimed to determine if the standardized uptake value (SUV) determined with 18F-FDG PET-CT can be used to predict radiation pneumonitis (RP) in lung cancer patients who receive radiotherapy. A total of 40 patients with non-small cell lung cancer received 18F-FDG PET-CT examinations prior to and following radiotherapy. The average SUV of lung tissue prior to and following radiation were measured at differing radiation doses. SUV differences between patients with and without RP, and the SUV ratio of the irradiated lung tissues compared with that of non-irradiated lung tissues (L/B) were compared. There were no differences in the mean SUV between the RP and no RP groups prior to radiotherapy. There were also no significant differences in the mean SUV of lung tissue within groups or between the no RP and RP groups with radiation doses of 0.05) following radiotherapy. There were, however, statistically significant differences in the mean SUV of lung tissue within groups or between the no RP and RP groups with doses of ≥60 Gy prior to therapy and 35 to ≤59.9 Gy and ≥60 Gy following therapy (all P<0.05). When the L/B ratio was ≥3, the incidence of RP was 50%, and when the L/B ratio was ≥2.5 the incidence was 40.7%. When the L/B ratio was <2, there were no cases of RP. In conclusion, the present study indicates that 18F-FDG PET-CT can be used to predict RP by L/B ratio.
- 25 August 2015
- Published by Spandidos Publications in Oncology Letters
- Vol. 10 (5) , 2909-2914
Open Access18FDG PET-CT standardized uptake value for the prediction of radiation pneumonitis in patients with lung cancer receiving radiotherapy
The present study aimed to determine if the standardized uptake value (SUV) determined with 18F-FDG PET-CT can be used to predict radiation pneumonitis (RP) in lung cancer patients who receive radiotherapy. A total of 40 patients with non-small cell lung cancer received 18F-FDG PET-CT examinations prior to and following radiotherapy. The average SUV of lung tissue prior to and following radiation were measured at differing radiation doses. SUV differences between patients with and without RP, and the SUV ratio of the irradiated lung tissues compared with that of non-irradiated lung tissues (L/B) were compared. There were no differences in the mean SUV between the RP and no RP groups prior to radiotherapy. There were also no significant differences in the mean SUV of lung tissue within groups or between the no RP and RP groups with radiation doses of 0.05) following radiotherapy. There were, however, statistically significant differences in the mean SUV of lung tissue within groups or between the no RP and RP groups with doses of ≥60 Gy prior to therapy and 35 to ≤59.9 Gy and ≥60 Gy following therapy (all P<0.05). When the L/B ratio was ≥3, the incidence of RP was 50%, and when the L/B ratio was ≥2.5 the incidence was 40.7%. When the L/B ratio was <2, there were no cases of RP. In conclusion, the present study indicates that 18F-FDG PET-CT can be used to predict RP by L/B ratio.
- 29 February 2012
- Published by Elsevier in Medical Dosimetry
- Vol. 36 (4) , 373-376
Conventional Craniospinal Irradiation with Patient Supine and Source-Skin Distance (SSD) 100 cm for Spinal Field
- 29 February 2012
- Published by Elsevier in Medical Dosimetry
- Vol. 36 (4) , 373-376
Conventional Craniospinal Irradiation with Patient Supine and Source-Skin Distance (SSD) 100 cm for Spinal Field
- 1 August 2009
- Vol. 31 (8) , 622-5
[Application of standardized uptake value for FDG PET-CT in predicting radiation pneumonitis].
To investigate the correlation of radiation pneumonitis (RP) with standardized uptake value (SUV) for fluorodeoxyglucose (FDG) positron emission tomography and computed tomography (PET-CT) in lung cancer patients treated with radiation therapy. Fourty patients with unresectable non-small cell lung cancer (NSCLC) received FDG PET-CT before and after radiotherapy. The average SUV of the lung tissue irradiated with a dose of < or = 5 Gy, 5.1 approximately 15 Gy, 15.1 approximately 35 Gy, 35.1 approximately 60 Gy, >60 Gy were measured. The correlation between SUV and RP was analyzed by comparing the SUV in the patients with RP and without. The SUV ratio of the irradiated lung tissue to that of the non-irradiated lung tissue (L/B) was also calculated. Of the 40 patients, 8 developed RP, including 6 cases of grade 2 and 2 cases of grade 3. The SUV of irradiated lung tissues with a dose of 35.1 approximately 60 Gy was significantly correlated with RP. When SUV > or =1, the RP incidence rate was 41.7% versus 20.0% in the whole group, with a statistically significant difference. (chi2 = 3.96, P < 0.05). The sensitivity and specificity of SUV in predicting RP was 62.5% and 78.1%, respectively. When the value of L/B > or = 2.5, the RP incidence rate was 40.7% in this group versus 20.0% in the whole group, with a statistical significance (chi(2) = 4.92, P < 0.05). If taking L/B > or = 2.5 as a threshold value, the sensitivity and specificity in predicting RP was 72.7% and 90.9%, respectively. No statistically significant difference was found in predicting radiation pneumonitis between SUV > or =1 and L/B > or = 2.5 (chi2 = 0.002, P > 0.05). The standardized uptake value (SUV) and the SUV ratio of the irradiated lung tissue to that of the non-irradiated lung tissue (L/B) for FDG PET-CT are positively correlated with radiation pneumonitis, and clinicians may use it to predict the occurrence of radiation pneumonitis.
- 1 August 2009
- Vol. 31 (8) , 622-5
[Application of standardized uptake value for FDG PET-CT in predicting radiation pneumonitis].
To investigate the correlation of radiation pneumonitis (RP) with standardized uptake value (SUV) for fluorodeoxyglucose (FDG) positron emission tomography and computed tomography (PET-CT) in lung cancer patients treated with radiation therapy. Fourty patients with unresectable non-small cell lung cancer (NSCLC) received FDG PET-CT before and after radiotherapy. The average SUV of the lung tissue irradiated with a dose of < or = 5 Gy, 5.1 approximately 15 Gy, 15.1 approximately 35 Gy, 35.1 approximately 60 Gy, >60 Gy were measured. The correlation between SUV and RP was analyzed by comparing the SUV in the patients with RP and without. The SUV ratio of the irradiated lung tissue to that of the non-irradiated lung tissue (L/B) was also calculated. Of the 40 patients, 8 developed RP, including 6 cases of grade 2 and 2 cases of grade 3. The SUV of irradiated lung tissues with a dose of 35.1 approximately 60 Gy was significantly correlated with RP. When SUV > or =1, the RP incidence rate was 41.7% versus 20.0% in the whole group, with a statistically significant difference. (chi2 = 3.96, P < 0.05). The sensitivity and specificity of SUV in predicting RP was 62.5% and 78.1%, respectively. When the value of L/B > or = 2.5, the RP incidence rate was 40.7% in this group versus 20.0% in the whole group, with a statistical significance (chi(2) = 4.92, P < 0.05). If taking L/B > or = 2.5 as a threshold value, the sensitivity and specificity in predicting RP was 72.7% and 90.9%, respectively. No statistically significant difference was found in predicting radiation pneumonitis between SUV > or =1 and L/B > or = 2.5 (chi2 = 0.002, P > 0.05). The standardized uptake value (SUV) and the SUV ratio of the irradiated lung tissue to that of the non-irradiated lung tissue (L/B) for FDG PET-CT are positively correlated with radiation pneumonitis, and clinicians may use it to predict the occurrence of radiation pneumonitis.
- 1 March 2007
- Vol. 29 (3) , 221-4
[FDG PET/CT versus PET alone for pre-surgical detection of lymph node metastasis in esophageal carcinoma].
To compare the combined FDG PET/CT with PET alone in the detection of lymph node metastasis (LNM) for esophageal carcinoma patient. From November 2003 to August 2005, 35 patients with esophageal carcinoma underwent FDG PET/CT before esophagectomy and lymph node (LN) dissection. The patients who had history of previous anticancer treatment or diabetes mellitus and inflammatory lung diseases as well as being inoperable for medical reasons were excluded. The results of LNM detection by PET/CT and PET alone were compared with pathological results. Twenty-nine men and 6 women were eligible for this study, with a mean age of 57 years (range: 40 to 72 years). Of these 35 patients, 3 had lesion at the upper third thoracic esophagus, 22 at the middle third and 10 at the lower third. All patients underwent surgical resection successfully. Twenty-five patients and 65 out of 313 excised nodal groups were found to have metastases by pathological examination. The true positive and true negative LNM interpretation reached 61 and 229 LN groups on PET/CT versus 53 and 217 LN groups on PET alone. False negative LNM interpretation was found in 12 LN groups on PET alone, and 8 of them were corrected by PET/CT including one cervical LN, 4 paraesophageal LNs, one left gastric arterial LN, one left gastric cardia LN, one lesser gastric curve LN. False positive interpretations on PET alone were found in 31 LN groups, 12 of them were corrected by PET/CT which included 9 false-positive interpretations due to physical tracer uptake (2 in the cervical region and 7 in gastrointestinal tract ) and 3 lesions with heterogeneous tracer uptake in the primary tumor. The sensitivity, specificity and accuracy of LNM detection by PET alone was 81.54% (53/65), 87.50% (217/248), and 86.26% (270/313), whereas by PET/CT, which was 93.85% (61/65), 91.24% (229/248) and 92.65% (290/313), respectively. There were statistically significant differences in sensitivity and accuracy of LNM detection between PET/CT and PET alone (0.033 and 0.009). Compared with FDG PET alone, FDG PET combined with CT can improve the sensitivity and accuracy in detection of lymph node metastasis in esophageal carcinoma.
- 1 March 2007
- Vol. 29 (3) , 221-4
[FDG PET/CT versus PET alone for pre-surgical detection of lymph node metastasis in esophageal carcinoma].
To compare the combined FDG PET/CT with PET alone in the detection of lymph node metastasis (LNM) for esophageal carcinoma patient. From November 2003 to August 2005, 35 patients with esophageal carcinoma underwent FDG PET/CT before esophagectomy and lymph node (LN) dissection. The patients who had history of previous anticancer treatment or diabetes mellitus and inflammatory lung diseases as well as being inoperable for medical reasons were excluded. The results of LNM detection by PET/CT and PET alone were compared with pathological results. Twenty-nine men and 6 women were eligible for this study, with a mean age of 57 years (range: 40 to 72 years). Of these 35 patients, 3 had lesion at the upper third thoracic esophagus, 22 at the middle third and 10 at the lower third. All patients underwent surgical resection successfully. Twenty-five patients and 65 out of 313 excised nodal groups were found to have metastases by pathological examination. The true positive and true negative LNM interpretation reached 61 and 229 LN groups on PET/CT versus 53 and 217 LN groups on PET alone. False negative LNM interpretation was found in 12 LN groups on PET alone, and 8 of them were corrected by PET/CT including one cervical LN, 4 paraesophageal LNs, one left gastric arterial LN, one left gastric cardia LN, one lesser gastric curve LN. False positive interpretations on PET alone were found in 31 LN groups, 12 of them were corrected by PET/CT which included 9 false-positive interpretations due to physical tracer uptake (2 in the cervical region and 7 in gastrointestinal tract ) and 3 lesions with heterogeneous tracer uptake in the primary tumor. The sensitivity, specificity and accuracy of LNM detection by PET alone was 81.54% (53/65), 87.50% (217/248), and 86.26% (270/313), whereas by PET/CT, which was 93.85% (61/65), 91.24% (229/248) and 92.65% (290/313), respectively. There were statistically significant differences in sensitivity and accuracy of LNM detection between PET/CT and PET alone (0.033 and 0.009). Compared with FDG PET alone, FDG PET combined with CT can improve the sensitivity and accuracy in detection of lymph node metastasis in esophageal carcinoma.
- 1 August 2006
- Vol. 47 (8) , 1255-9
Additional value of PET/CT over PET in assessment of locoregional lymph nodes in thoracic esophageal squamous cell cancer.
The aim of this study was to compare the value of reviewing combined 18F-FDG PET/CT images with that of reviewing side-by-side PET and CT images in the diagnosis of locoregional lymph node metastases in patients with esophageal squamous cell cancer. From November 2003 to December 2005, 45 patients with thoracic esophageal squamous cell cancer underwent 18F-FDG PET/CT before surgery. The results of reviewing combined PET/CT images and side-by-side PET and CT images for the diagnosis of locoregional lymph node metastases were compared prospectively in relation to pathologic findings. All patients underwent successful surgery, and pathologic examination confirmed nodes positive for metastasis in 32 patients and 82 of 397 excised nodal groups. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of PET/CT were 93.90% (77/82 nodal groups), 92.06% (290/315), 92.44% (367/397), 75.49% (77/102), and 98.31% (290/295), respectively, whereas those of PET were 81.71% (67/82), 87.30% (275/315), 86.15% (342/397), 62.62% (67/107), and 94.83% (275/290), respectively. P values were 0.032, 0.067, 0.006, 0.063, and 0.037, respectively. The differences in sensitivity, accuracy, and negative predictive value between PET and PET/CT were statistically significant. PET/CT improves the sensitivity, accuracy, and negative predictive value of 18F-FDG imaging in the assessment of locoregional lymph nodes in thoracic esophageal squamous cell cancer and provides data of diagnostic significance.
- 1 August 2006
- Vol. 47 (8) , 1255-9
Additional value of PET/CT over PET in assessment of locoregional lymph nodes in thoracic esophageal squamous cell cancer.
The aim of this study was to compare the value of reviewing combined 18F-FDG PET/CT images with that of reviewing side-by-side PET and CT images in the diagnosis of locoregional lymph node metastases in patients with esophageal squamous cell cancer. From November 2003 to December 2005, 45 patients with thoracic esophageal squamous cell cancer underwent 18F-FDG PET/CT before surgery. The results of reviewing combined PET/CT images and side-by-side PET and CT images for the diagnosis of locoregional lymph node metastases were compared prospectively in relation to pathologic findings. All patients underwent successful surgery, and pathologic examination confirmed nodes positive for metastasis in 32 patients and 82 of 397 excised nodal groups. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of PET/CT were 93.90% (77/82 nodal groups), 92.06% (290/315), 92.44% (367/397), 75.49% (77/102), and 98.31% (290/295), respectively, whereas those of PET were 81.71% (67/82), 87.30% (275/315), 86.15% (342/397), 62.62% (67/107), and 94.83% (275/290), respectively. P values were 0.032, 0.067, 0.006, 0.063, and 0.037, respectively. The differences in sensitivity, accuracy, and negative predictive value between PET and PET/CT were statistically significant. PET/CT improves the sensitivity, accuracy, and negative predictive value of 18F-FDG imaging in the assessment of locoregional lymph nodes in thoracic esophageal squamous cell cancer and provides data of diagnostic significance.