Yohei Takeshita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yohei Takeshita has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Kazunori Yoshiura
Department of Oral and Maxillofacial Radiology, Faculty of Dental Science, Kyushu University, Fukuoka, Japan
3 shared publications - Kazutoshi Okamura
Department of Oral and Maxillofacial Radiology, Faculty of Dental Science, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
3 shared publications - Mayumi Shimizu
Department of Oral and Maxillofacial Radiology, Kyushu University Hospital, Fukuoka, Japan
3 shared publications - Kenji Tokumori
Department of Radiological Technology, Faculty of Fukuoka Medical Technology, Teikyo University, Fukuoka, Japan
2 shared publications - Warangkana Weerawanich
Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
2 shared publications - Gainer R Jasa
Oral Radiology Division, University of the Republic, Montevideo, Uruguay
1 shared publication
Latest Publications
- 1 April 2017
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 46 (4) , 20160315
Effects of exposure parameters and slice thickness on detecting clear and unclear mandibular canals using cone beam CT
Objectives:The purpose of this study was to clarify the effects of exposure parameters and image-processing methods when using CBCT to detect clear and unclear mandibular canals (MCs).Methods:24 dry half mandibles were divided into 2 groups with clear and unclear MCs based on a previous CBCT study. Mandibles were scanned using a CBCT system with varying exposure parameters (tube voltages 60 kV, 70 kV and 90 kV; and tube currents 2 mA, 5 mA, 10 mA and 15 mA) to obtain a total of 144 scans. The images were processed with different slice thicknesses using ImageJ software (National Institutes of Health, Bethesda, MD). Five radiologists evaluated the cross-sectional images of the first molar region to detect the MCs. The diagnostic accuracy of varying exposure parameters and image-processing conditions was compared with the area under the curve (Az) in receiver-operating characteristic analysis.Results:The Az values for clear MCs were higher than those for unclear MCs (p < 0.0001). With increasing exposure vol...
- 1 April 2017
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 46 (4) , 20160315
Effects of exposure parameters and slice thickness on detecting clear and unclear mandibular canals using cone beam CT
Objectives:The purpose of this study was to clarify the effects of exposure parameters and image-processing methods when using CBCT to detect clear and unclear mandibular canals (MCs).Methods:24 dry half mandibles were divided into 2 groups with clear and unclear MCs based on a previous CBCT study. Mandibles were scanned using a CBCT system with varying exposure parameters (tube voltages 60 kV, 70 kV and 90 kV; and tube currents 2 mA, 5 mA, 10 mA and 15 mA) to obtain a total of 144 scans. The images were processed with different slice thicknesses using ImageJ software (National Institutes of Health, Bethesda, MD). Five radiologists evaluated the cross-sectional images of the first molar region to detect the MCs. The diagnostic accuracy of varying exposure parameters and image-processing conditions was compared with the area under the curve (Az) in receiver-operating characteristic analysis.Results:The Az values for clear MCs were higher than those for unclear MCs (p < 0.0001). With increasing exposure vol...
- 1 March 2017
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 46 (3) , 20160331
A new method to evaluate image quality of CBCT images quantitatively without observers
To develop an observer-free method for quantitatively evaluating the image quality of CBCT images by applying just-noticeable difference (JND). We used two test objects: (1) a Teflon (polytetrafluoroethylene) plate phantom attached to a dry human mandible; and (2) a block phantom consisting of a Teflon step phantom and an aluminum step phantom. These phantoms had holes with different depths. They were immersed in water and scanned with a CB MercuRay at tube voltages of 120, 100, 80, and 60 kV. Superimposed images of the phantoms with holes were used for evaluation. The number of detectable holes was used as an index of image quality. In detecting holes quantitatively, the threshold gray value (ΔG) which differentiated holes from the background was calculated using a specific threshold (the JND), and we extracted the holes with gray values above ΔG. The indexes obtained by this quantitative method (the extracted hole values) were compared with the observers’ evaluations (the observed hole values). In addition, the contrast-to-noise ratio (CNR) of the shallowest detectable holes and the deepest undetectable holes were measured to evaluate the contribution of CNR to detectability. The results of this evaluation method corresponded almost exactly with the evaluations made by observers. The extracted hole values reflected the influence of different tube voltages. All extracted holes had an area with a CNR of ≥1.5. This quantitative method of evaluating CBCT image quality may be more useful and less time-consuming than evaluation by observation.
- 1 March 2017
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 46 (3) , 20160331
A new method to evaluate image quality of CBCT images quantitatively without observers
To develop an observer-free method for quantitatively evaluating the image quality of CBCT images by applying just-noticeable difference (JND). We used two test objects: (1) a Teflon (polytetrafluoroethylene) plate phantom attached to a dry human mandible; and (2) a block phantom consisting of a Teflon step phantom and an aluminum step phantom. These phantoms had holes with different depths. They were immersed in water and scanned with a CB MercuRay at tube voltages of 120, 100, 80, and 60 kV. Superimposed images of the phantoms with holes were used for evaluation. The number of detectable holes was used as an index of image quality. In detecting holes quantitatively, the threshold gray value (ΔG) which differentiated holes from the background was calculated using a specific threshold (the JND), and we extracted the holes with gray values above ΔG. The indexes obtained by this quantitative method (the extracted hole values) were compared with the observers’ evaluations (the observed hole values). In addition, the contrast-to-noise ratio (CNR) of the shallowest detectable holes and the deepest undetectable holes were measured to evaluate the contribution of CNR to detectability. The results of this evaluation method corresponded almost exactly with the evaluations made by observers. The extracted hole values reflected the influence of different tube voltages. All extracted holes had an area with a CNR of ≥1.5. This quantitative method of evaluating CBCT image quality may be more useful and less time-consuming than evaluation by observation.
- Open Access
- 23 August 2015
- Published by Springer Nature in Arthritis Research & Therapy
- Vol. 17 (1) , 1-11
Effectiveness of imaging modalities for screening IgG4-related dacryoadenitis and sialadenitis (Mikulicz’s disease) and for differentiating it from Sjögren’s syndrome (SS), with an emphasis on sonography
The aim of this study was to clarify the effectiveness of various imaging modalities and characteristic imaging features in the screening of IgG4-related dacryoadenitis and sialadenitis (IgG4-DS), and to show the differences in the imaging features between IgG4-DS and Sjögren’s syndrome (SS). Thirty-nine patients with IgG4-DS, 51 with SS and 36 with normal salivary glands were enrolled. Images of the parotid and submandibular glands obtained using sonography, 2-[18F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (FDG-PET/CT), computed tomography (CT) and magnetic resonance imaging (MRI) were retrospectively analyzed. Six oral and maxillofacial radiologists randomly reviewed the arranged image sets under blinded conditions. Each observer scored the confidence rating regarding the presence of the characteristic imaging findings using a 5-grade rating system. After scoring various findings, diagnosis was made as normal, IgG4-DS or SS, considering all findings for each case. On sonography, multiple hypoechoic areas and hyperechoic lines and/or spots in the parotid glands and obscuration of submandibular gland configuration were detected mainly in patients with SS (median scores 4, 4 and 3, respectively). Reticular and nodal patterns were observed primarily in patients with IgG4-DS (median score 5). FDG-PET/CT revealed a tendency for abnormal 18F-FDG accumulation and swelling of both the parotid and submandibular glands in patients with IgG4-DS, particularly in the submandibular glands. On MRI, SS had a high score regarding the findings of a salt-and-pepper appearance and/or multiple cystic areas in the parotid glands (median score 4.5). Sonography showed the highest values among the four imaging modalities for sensitivity, specificity and accuracy. There were significant differences between sonography and CT (p = 0.0001) and between sonography and FDG-PET/CT (p = 0.0058) concerning accuracy. Changes in the submandibular glands affected by IgG4-DS could be easily detected using sonography (characteristic bilateral nodal/reticular change) and FDG-PET/CT (abnormal 18F-FDG accumulation). Even inexperienced observers could detect these findings. In addition, sonography could also differentiate SS. Consequently, we recommend sonography as a modality for the screening of IgG4-DS, because it is easy to use, involves no radiation exposure and is an effective imaging modality.
- 23 August 2015
- Published by Springer Nature in Arthritis Research & Therapy
- Vol. 17 (1) , 1-11
Open AccessEffectiveness of imaging modalities for screening IgG4-related dacryoadenitis and sialadenitis (Mikulicz’s disease) and for differentiating it from Sjögren’s syndrome (SS), with an emphasis on sonography
The aim of this study was to clarify the effectiveness of various imaging modalities and characteristic imaging features in the screening of IgG4-related dacryoadenitis and sialadenitis (IgG4-DS), and to show the differences in the imaging features between IgG4-DS and Sjögren’s syndrome (SS). Thirty-nine patients with IgG4-DS, 51 with SS and 36 with normal salivary glands were enrolled. Images of the parotid and submandibular glands obtained using sonography, 2-[18F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (FDG-PET/CT), computed tomography (CT) and magnetic resonance imaging (MRI) were retrospectively analyzed. Six oral and maxillofacial radiologists randomly reviewed the arranged image sets under blinded conditions. Each observer scored the confidence rating regarding the presence of the characteristic imaging findings using a 5-grade rating system. After scoring various findings, diagnosis was made as normal, IgG4-DS or SS, considering all findings for each case. On sonography, multiple hypoechoic areas and hyperechoic lines and/or spots in the parotid glands and obscuration of submandibular gland configuration were detected mainly in patients with SS (median scores 4, 4 and 3, respectively). Reticular and nodal patterns were observed primarily in patients with IgG4-DS (median score 5). FDG-PET/CT revealed a tendency for abnormal 18F-FDG accumulation and swelling of both the parotid and submandibular glands in patients with IgG4-DS, particularly in the submandibular glands. On MRI, SS had a high score regarding the findings of a salt-and-pepper appearance and/or multiple cystic areas in the parotid glands (median score 4.5). Sonography showed the highest values among the four imaging modalities for sensitivity, specificity and accuracy. There were significant differences between sonography and CT (p = 0.0001) and between sonography and FDG-PET/CT (p = 0.0058) concerning accuracy. Changes in the submandibular glands affected by IgG4-DS could be easily detected using sonography (characteristic bilateral nodal/reticular change) and FDG-PET/CT (abnormal 18F-FDG accumulation). Even inexperienced observers could detect these findings. In addition, sonography could also differentiate SS. Consequently, we recommend sonography as a modality for the screening of IgG4-DS, because it is easy to use, involves no radiation exposure and is an effective imaging modality.