Tetsuya Sakamoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tetsuya Sakamoto has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Hajime Seo
Department of Orthopaedic Surgery, Faculty of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-ku, Fukuoka 814-0180, Japan
1 shared publication - Koichi Kinoshita
Department of Orthopaedic Surgery, Fukuoka University Faculty of Medicine, 7-45-1 Nanakuma, Jonan-ku, Fukuoka 814-0180, Japan
1 shared publication - Masahiro Suzuki
Department of Orthopaedic Surgery, Faculty of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-ku, Fukuoka 814-0180, Japan
1 shared publication Masatoshi Naito
Department of Orthopaedic Surgery School of Medicine, Fukuoka University, Fukuoka, Japan
1 shared publication- Sakae Kinoshita
Department of Orthopaedic Surgery, Faculty of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-ku, Fukuoka 814-0180, Japan
1 shared publication - Takuaki Yamamoto
Department of Orthopedic Surgery, Fukuoka University Faculty of Medicine, Fukuoka, Japan
1 shared publication
Latest Publications
- Open Access
- 22 August 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (17) , 5444
Sequential Intraoperative Evaluation of Rotational Stability of Cementless Stem in Total Hip Arthroplasty: A Broach-Based Study
In cementless total hip arthroplasty, the rotational stability of the stem is generally confirmed in a one-time manual evaluation by the surgeon. This study was performed to evaluate the sequential intraoperative changes in rotational stability using a torque wrench. Primary total hip arthroplasty was performed on 52 consecutive hips using a single wedge stem design. Intraoperative evaluation of rotational stability was uniformly performed using a torque wrench. Evaluations were performed immediately after broach insertion and immediately before the final insertion of the stem (after placement of the acetabular cup). Immediately after the insertion of the broach, rotational stability was checked and confirmed to be fully stabilized using a torque wrench in all cases, and the stability was maintained in 17 of 52 (33%) hips immediately before the final insertion of the stem. Among the hips showing instability, 11 of 35 (31%) broaches were upsized, while the remaining 24 hips achieved stabilization through deeper insertion of the broach. In conclusion, the rotational stability achieved immediately after the insertion of the broach was not necessarily maintained during surgery, indicating that rotational stability may need to be checked at multiple time points intraoperatively.
- 22 August 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (17) , 5444
Open AccessSequential Intraoperative Evaluation of Rotational Stability of Cementless Stem in Total Hip Arthroplasty: A Broach-Based Study
In cementless total hip arthroplasty, the rotational stability of the stem is generally confirmed in a one-time manual evaluation by the surgeon. This study was performed to evaluate the sequential intraoperative changes in rotational stability using a torque wrench. Primary total hip arthroplasty was performed on 52 consecutive hips using a single wedge stem design. Intraoperative evaluation of rotational stability was uniformly performed using a torque wrench. Evaluations were performed immediately after broach insertion and immediately before the final insertion of the stem (after placement of the acetabular cup). Immediately after the insertion of the broach, rotational stability was checked and confirmed to be fully stabilized using a torque wrench in all cases, and the stability was maintained in 17 of 52 (33%) hips immediately before the final insertion of the stem. Among the hips showing instability, 11 of 35 (31%) broaches were upsized, while the remaining 24 hips achieved stabilization through deeper insertion of the broach. In conclusion, the rotational stability achieved immediately after the insertion of the broach was not necessarily maintained during surgery, indicating that rotational stability may need to be checked at multiple time points intraoperatively.
- 29 August 2015
- Published by Springer Nature in International Orthopaedics
- Vol. 39 (11) , 2281-2286
Outcome of peri-acetabular osteotomy for hip dysplasia in teenagers
Peri-acetabular osteotomy, especially curved peri-acetabular osteotomy, is an effective surgical procedure for re-orientating the acetabulum. However, there have been few reports on this procedure in teenagers. The purpose of this study was to investigate the treatment outcomes of curved peri-acetabular osteotomy in teenagers.
- 29 August 2015
- Published by Springer Nature in International Orthopaedics
- Vol. 39 (11) , 2281-2286
Outcome of peri-acetabular osteotomy for hip dysplasia in teenagers
Peri-acetabular osteotomy, especially curved peri-acetabular osteotomy, is an effective surgical procedure for re-orientating the acetabulum. However, there have been few reports on this procedure in teenagers. The purpose of this study was to investigate the treatment outcomes of curved peri-acetabular osteotomy in teenagers.