OTO. Teshima

O. Teshima

*This is an algorithmically generated author record based on publicly available information.

O. Teshima has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Non-Destructive Examination of Jacket Sections for ITER Central Solenoid Conductors

    by Y. Takahashi, T. Suwa, Y. Nabara, H. Ozeki, T. Hemmi, Y. Nunoya, T. Isono, K. Matsui, K. Kawano, M. Oshikiri, et al.

    The Japan Atomic Energy Agency is responsible for procuring all amounts of central solenoid (CS) conductors for International Thermonuclear Experimental Reactor, including CS jacket sections. The conductor is cable-in-conduit conductor with a central spiral. A total of 576 Nb 3 Sn strands and 288 copper strands are cabled around the central spiral and then wrapped with stainless steel tape whose thickness is 0.08 mm. The maximum operating current is 40 kA at magnetic field of 13 T. CS jacket section is circular in square type tube made of JK2LB, which is high manganese stainless steel with boron added. Unit length of jacket sections is 7 m, and 6400 sections will be manufactured and inspected. Outer/inner dimension and weight are 51.3/35.3 mm and around 100 kg, respectively. Since the CS conductor suffers 60000 cycles of high electromagnetic force in the lifetime, severe requirements were specified for jacket sections in terms of not only high mechanical performance at 4 K but also of the size of initial defects in the jacket section. The minimum allowable defect size is estimated to be 2 mm2 × 0.2 mm by linear elastic fracture mechanics. Eddy current test (ECT) and phased array ultrasonic test (PAUT) were developed for non-destructive examination. The defects on inner and outer surfaces can be detected by ECT. The defects inside the jacket section can be detected by PAUT. These technologies and the inspected results of more than 700 jacket sections are reported in this paper.


  • Effect of specimen shape on the elongation of 316LN jacket used in the ITER toroidal field coil

    by K. Hamada, K. Kawano, T. Saito, M. Iguchi, H. Nakajima, O. Teshima, H. Matsuda

    Twenty-five percent of the total toroidal field (TF) coil conductors at the ITER are supplied by the Japan Atomic Energy Agency (JAEA). The jacket section of a TF conductor is made of modified 316LN. The JAEA tested three types of tensile specimens (Japanese-Industrial-Standards-type and ASTM-type) cut from the jacket at 4.2 K. The ASTM-type specimen had a longer and wider reduced section than did the JIS-type specimen. The results of the test showed that the EL of the as-received (AR) jacket was independent of the specimen shape. However, after cold working and aging, the EL of the specimens deteriorated because of sensitization, and the EL distribution in these specimens was larger than that in the case of the AR specimens. It could be inferred that the shape of a test specimen having low ductility is the key determinant of the specimen's susceptibility to fracture.