SHSimon Holland

Simon Holland

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Simon Holland has a total of 76 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    User Requirements for a Clinical Interface to Support Lower Limb Rehabilitation Using Wearable Inertial Sensors: An Iterative Design Study (Preprint)

    by Riasat Islam, Simon Holland, Blaine Price, Paul Mulholland

    BACKGROUND Wearable inertial sensors offer a promising approach for objective movement analysis in rehabilitation. However, despite advances in sensing accuracy, adoption in clinical practice remains limited. One barrier is the lack of clinician-facing software interfaces that translate sensor data into clinically interpretable information aligned with rehabilitation workflows. OBJECTIVE We aimed to identify clinician-centred user requirements and interface design considerations for wearable inertial sensor systems supporting lower-limb rehabilitation. METHODS We conducted an iterative user-centred design study with three clinicians involved in rehabilitation: a neuro-physiotherapist, a musculoskeletal physiotherapist, and an orthopaedic surgeon. The study consisted of (1) semi-structured interviews to elicit clinical requirements, (2) think-aloud evaluation of an initial wireframe interface mockup, and (3) evaluation of a revised mockup informed by earlier feedback. Sessions were audio-recorded, transcribed, and analysed using thematic analysis to identify clinician requirements and interface design considerations. RESULTS We identified four clinician-centred requirement themes spanning clinically meaningful movement metrics beyond standard functional tests, pragmatic sensor setup and calibration, interpretable longitudinal visualisation, and workflow-aligned reporting and task support. Across these requirement areas, clinicians consistently indicated that interpretability, setup burden, and workflow fit would influence whether such a system would be practical and acceptable in routine use. CONCLUSIONS Through iterative engagement with clinicians, this study identifies rehabilitation-specific interface requirements for wearable inertial sensor systems in lower-limb rehabilitation. These findings articulate how successful translation into practice depends on concrete design features such as guided sensor placement, calibration options suited to patients with limited mobility, interpretable longitudinal visualisation, and reporting features that fit routine clinical work. Together, they provide early-stage design guidance on how clinician-facing rehabilitation interfaces should structure setup, calibration, visualisation, and reporting when presenting wearable-derived movement data.

  • Using rhythm for rehabilitation: the acceptability of a novel haptic cueing device in extended stroke rehabilitation

    by Josephine Wendy Tetley, Simon Holland, Sue Caton, Glenis Donaldson, Theodoros Georgiou, Federico Visi, Rachel Christina Stockley

    Purpose: Restoration of walking ability is a key goal to both stroke survivors and their therapists. However, the intensity and duration of rehabilitation available after stroke can be limited by service constraints, despite the potential for improvement which could reduce health service demands in the long run. The purpose of this paper is to present qualitative findings from a study that explored the acceptability of a haptic device aimed at improving walking as part of an extended intervention in stroke rehabilitation.Design/methodology/approach: Pre-trial focus groups and post-trial interviews to assess the acceptability of Haptic Bracelets were undertaken with seven stroke survivors.Findings: Five themes were identified as impacting on the acceptability of the Haptic Bracelet: potential for improving quality of life; relationships with technology; important features; concerns; response to trial and concentration. Participants were interested in the haptic bracelet and hoped it would provide them with more confidence making them: feel safer when walking; have greater ability to take bigger strides rather than little steps; a way to combat mistakes participants reported making due to tiredness and reduced pain in knees and hips.Originality/value: Haptic Bracelets are an innovative development in the field of rhythmic cueing and stroke rehabilitation. The haptic bracelets also overcome problems encountered with established audio-based cueing, as their use is not affected by external environmental noise.Peer review: The peer review history for this article is available at: https://publons.com/publon 10.1108/JET-01-2021-0003


  • Open Access

    Liberating Methods for Music Interaction

    by Tom Mudd, Simon Holland

  • Open Access

    Rhythmic Haptic Cueing for Gait Rehabilitation of People With Hemiparesis: Quantitative Gait Study

    by Theodoros Georgiou, Simon Holland, Janet van der Linden

    Background: Rhythm, brain, and body are closely linked. Humans can synchronize their movement to auditory rhythms in ways that can improve the regularity of movement while reducing perceived effort. However, the ability to perform rhythmic movement may be disrupted by various neurological conditions. Many such conditions impair mechanisms that control movement, such as gait, but typically without rhythmic perception being affected. This paper focuses on hemiparetic stroke, a neurological condition that affects one side of the body. Hemiparetic stroke can cause severe asymmetries in gait, leading to numerous physical problems ranging from muscle degeneration to bone fractures. Movement synchronization via entrainment to auditory metronomes is known to improve asymmetry and related gait problems; this paper presents the first systematic study of entrainment for gait rehabilitation via the haptic modality. Objective: This paper explores the gait rehabilitation of people with hemiparesis following a stroke or brain injury, by a process of haptic entrainment to rhythmic cues. Various objective measures, such as stride length and stride time, are considered. Methods: This study is a quantitative gait study combining temporal and spatial data on haptically cued participants with hemiparetic stroke and brain injury. We designed wearable devices to deliver the haptic rhythm, called Haptic Bracelets, which were placed on the leg near the knee. Spatial data were recorded using a Qualisys optical motion capturing system, consisting of 8 optoelectronic cameras, and 20 markers placed on anatomical lower limb landmarks and 4 additional tracking clusters placed on the right and left shank and thigh. Gait characteristics were measured before, during, and after cueing. Results: All 11 successfully screened participants were able to synchronize their steps to a haptically presented rhythm. Specifically, 6 participants demonstrated immediate improvements regarding their temporal gait characteristics, and 3 of the 6 improved their gait in terms of spatial characteristics. Conclusions: Considering the great variability between survivors of stroke and brain injury and the limited number of available participants in our study, there is no claim of statistical evidence that supports a formal experimental result of improved gait. However, viewing this empirical gait investigation as a set of 11 case studies, more modest empirical claims can be made. All participants were able to synchronize their steps to a haptically presented rhythm. For a substantial proportion of participants, an immediate (though not necessarily lasting) improvement of temporal gait characteristics was found during cueing. Some improvements over baseline occurred immediately after, rather than during, haptic cueing. Design issues and trade-offs are identified, and interactions between perception, sensory deficit, attention, memory, cognitive load, and haptic entrainment are noted.


  • Open Access

    Rhythmic Haptic Cueing Using Wearable Devices as Physiotherapy for Huntington Disease: Case Study

    by Theodoros Georgiou, Riasat Islam, Simon Holland, Janet van der Linden, Blaine Price, Paul Mulholland, Allan Perry

    Background: Huntington disease (HD) is an inherited genetic disorder that results in the death of brain cells. HD symptoms generally start with subtle changes in mood and mental abilities; they then degenerate progressively, ensuing a general lack of coordination and an unsteady gait, ultimately resulting in death. There is currently no cure for HD. Walking cued by an external, usually auditory, rhythm has been shown to steady gait and help with movement coordination in other neurological conditions. More recently, work with other neurological conditions has demonstrated that haptic (ie, tactile) rhythmic cues, as opposed to audio cues, offer similar improvements when walking. An added benefit is that less intrusive, more private cues are delivered by a wearable device that leaves the ears free for conversation, situation awareness, and safety. This paper presents a case study where rhythmic haptic cueing (RHC) was applied to one person with HD. The case study has two elements: the gait data we collected from our wearable devices and the comments we received from a group of highly trained expert physiotherapists and specialists in HD. Objective: The objective of this case study was to investigate whether RHC can be applied to improve gait coordination and limb control in people living with HD. While not offering a cure, therapeutic outcomes may delay the onset or severity of symptoms, with the potential to improve and prolong quality of life. Methods: The approach adopted for this study includes two elements, one quantitative and one qualitative. The first is a repeated-measures design with three conditions: before haptic rhythm (ie, baseline), with haptic rhythm, and after exposure to haptic rhythm. The second element is an in-depth interview with physiotherapists observing the session. Results: In comparison to the baseline, the physiotherapists noted a number of improvements to the participant’s kinematics during her walk with the haptic cues. These improvements continued in the after-cue condition, indicating some lasting effects. The quantitative data obtained support the physiotherapists’ observations. Conclusions: The findings from this small case study, with a single participant, suggest that a haptic metronomic rhythm may have immediate, potentially therapeutic benefits for the walking kinematics of people living with HD and warrants further investigation.


  • Open Access

    A Nonproprietary Movement Analysis System (MoJoXlab) Based on Wearable Inertial Measurement Units Applicable to Healthy Participants and Those With Anterior Cruciate Ligament Reconstruction Across a Range of Complex Tasks: Validation Study

    by Riasat Islam, Mohamed Bennasar, Kevin Nicholas, Kate Button, Simon Holland, Paul Mulholland, Blaine Price, Mohammad Al-Amri

    Background: Movement analysis in a clinical setting is frequently restricted to observational methods to inform clinical decision making, which has limited accuracy. Fixed-site, optical, expensive movement analysis laboratories provide gold standard kinematic measurements; however, they are rarely accessed for routine clinical use. Wearable inertial measurement units (IMUs) have been demonstrated as comparable, inexpensive, and portable movement analysis toolkits. MoJoXlab has therefore been developed to work with generic wearable IMUs. However, before using MoJoXlab in clinical practice, there is a need to establish its validity in participants with and without knee conditions across a range of tasks with varying complexity. Objective: This paper aimed to present the validation of MoJoXlab software for using generic wearable IMUs for calculating hip, knee, and ankle joint angle measurements in the sagittal, frontal, and transverse planes for walking, squatting, and jumping in healthy participants and those with anterior cruciate ligament (ACL) reconstruction. Methods: Movement data were collected from 27 healthy participants and 20 participants with ACL reconstruction. In each case, the participants wore seven MTw2 IMUs (Xsens Technologies) to monitor their movement in walking, jumping, and squatting tasks. The hip, knee, and ankle joint angles were calculated in the sagittal, frontal, and transverse planes using two different software packages: Xsens’ validated proprietary MVN Analyze and MoJoXlab. The results were validated by comparing the generated waveforms, cross-correlation (CC), and normalized root mean square error (NRMSE) values. Results: Across all joints and activities, for data of both healthy and ACL reconstruction participants, the CC and NRMSE values for the sagittal plane are 0.99 (SD 0.01) and 0.042 (SD 0.025); 0.88 (SD 0.048) and 0.18 (SD 0.078) for the frontal plane; and 0.85 (SD 0.027) and 0.23 (SD 0.065) for the transverse plane (hip and knee joints only). On comparing the results from the two different software systems, the sagittal plane was very highly correlated, with frontal and transverse planes showing strong correlation. Conclusions: This study demonstrates that nonproprietary software such as MoJoXlab can accurately calculate joint angles for movement analysis applications comparable with proprietary software for walking, squatting, and jumping in healthy individuals and those following ACL reconstruction. MoJoXlab can be used with generic wearable IMUs that can provide clinicians accurate objective data when assessing patients’ movement, even when changes are too small to be observed visually. The availability of easy-to-setup, nonproprietary software for calibration, data collection, and joint angle calculation has the potential to increase the adoption of wearable IMU sensors in clinical practice, as well as in free living conditions, and may provide wider access to accurate, objective assessment of patients’ progress over time.


  • Open Access

    Rhythmic Haptic Cueing for Gait Rehabilitation of People With Hemiparesis: Quantitative Gait Study (Preprint)

    by Theodoros Georgiou, Simon Holland, Janet van der Linden

    BACKGROUND Rhythm, brain, and body are closely linked. Humans can synchronize their movement to auditory rhythms in ways that can improve the regularity of movement while reducing perceived effort. However, the ability to perform rhythmic movement may be disrupted by various neurological conditions. Many such conditions impair mechanisms that control movement, such as gait, but typically without rhythmic perception being affected. This paper focuses on hemiparetic stroke, a neurological condition that affects one side of the body. Hemiparetic stroke can cause severe asymmetries in gait, leading to numerous physical problems ranging from muscle degeneration to bone fractures. Movement synchronization via entrainment to auditory metronomes is known to improve asymmetry and related gait problems; this paper presents the first systematic study of entrainment for gait rehabilitation via the haptic modality. OBJECTIVE This paper explores the gait rehabilitation of people with hemiparesis following a stroke or brain injury, by a process of haptic entrainment to rhythmic cues. Various objective measures, such as stride length and stride time, are considered. METHODS This study is a quantitative gait study combining temporal and spatial data on haptically cued participants with hemiparetic stroke and brain injury. We designed wearable devices to deliver the haptic rhythm, called Haptic Bracelets, which were placed on the leg near the knee. Spatial data were recorded using a Qualisys optical motion capturing system, consisting of 8 optoelectronic cameras, and 20 markers placed on anatomical lower limb landmarks and 4 additional tracking clusters placed on the right and left shank and thigh. Gait characteristics were measured before, during, and after cueing. RESULTS All 11 successfully screened participants were able to synchronize their steps to a haptically presented rhythm. Specifically, 6 participants demonstrated immediate improvements regarding their temporal gait characteristics, and 3 of the 6 improved their gait in terms of spatial characteristics. CONCLUSIONS Considering the great variability between survivors of stroke and brain injury and the limited number of available participants in our study, there is no claim of statistical evidence that supports a formal experimental result of improved gait. However, viewing this empirical gait investigation as a set of 11 case studies, more modest empirical claims can be made. All participants were able to synchronize their steps to a haptically presented rhythm. For a substantial proportion of participants, an immediate (though not necessarily lasting) improvement of temporal gait characteristics was found during cueing. Some improvements over baseline occurred immediately after, rather than during, haptic cueing. Design issues and trade-offs are identified, and interactions between perception, sensory deficit, attention, memory, cognitive load, and haptic entrainment are noted.


  • Open Access

    Rhythmic Haptic Cueing Using Wearable Devices as Physiotherapy for Huntington Disease: Case Study (Preprint)

    by Theodoros Georgiou, Riasat Islam, Simon Holland, Janet van der Linden, Blaine Price, Paul Mulholland, Allan Perry

    BACKGROUND Huntington disease (HD) is an inherited genetic disorder that results in the death of brain cells. HD symptoms generally start with subtle changes in mood and mental abilities; they then degenerate progressively, ensuing a general lack of coordination and an unsteady gait, ultimately resulting in death. There is currently no cure for HD. Walking cued by an external, usually auditory, rhythm has been shown to steady gait and help with movement coordination in other neurological conditions. More recently, work with other neurological conditions has demonstrated that haptic (ie, tactile) rhythmic cues, as opposed to audio cues, offer similar improvements when walking. An added benefit is that less intrusive, more private cues are delivered by a wearable device that leaves the ears free for conversation, situation awareness, and safety. This paper presents a case study where rhythmic haptic cueing (RHC) was applied to one person with HD. The case study has two elements: the gait data we collected from our wearable devices and the comments we received from a group of highly trained expert physiotherapists and specialists in HD. OBJECTIVE The objective of this case study was to investigate whether RHC can be applied to improve gait coordination and limb control in people living with HD. While not offering a cure, therapeutic outcomes may delay the onset or severity of symptoms, with the potential to improve and prolong quality of life. METHODS The approach adopted for this study includes two elements, one quantitative and one qualitative. The first is a repeated-measures design with three conditions: before haptic rhythm (ie, baseline), with haptic rhythm, and after exposure to haptic rhythm. The second element is an in-depth interview with physiotherapists observing the session. RESULTS In comparison to the baseline, the physiotherapists noted a number of improvements to the participant’s kinematics during her walk with the haptic cues. These improvements continued in the after-cue condition, indicating some lasting effects. The quantitative data obtained support the physiotherapists’ observations. CONCLUSIONS The findings from this small case study, with a single participant, suggest that a haptic metronomic rhythm may have immediate, potentially therapeutic benefits for the walking kinematics of people living with HD and warrants further investigation.

  • The Role of Nonlinear Dynamics in Musicians' Interactions with Digital and Acoustic Musical Instruments

    by Tom Mudd, Simon Holland, Paul Mulholland

    Nonlinear dynamic processes are fundamental to the behavior of acoustic musical instruments, as is well explored in the case of sound production. Such processes may have profound and under-explored implications for how musicians interact with instruments, however. Although nonlinear dynamic processes are ubiquitous in acoustic instruments, they are present in digital musical tools only if explicitly implemented. Thus, an important resource with potentially major effects on how musicians interact with acoustic instruments is typically absent in the way musicians interact with digital instruments. Twenty-four interviews with free-improvising musicians were conducted to explore the role that nonlinear dynamics play in the participants' musical practices and to understand how such processes can afford distinctive methods of creative exploration. Thematic analysis of the interview data is used to demonstrate the potential for nonlinear dynamic processes to provide repeatable, learnable, controllable, and explorable interactions, and to establish a vocabulary for exploring nonlinear dynamic interactions. Two related approaches to engaging with nonlinear dynamic behaviors are elaborated: edge-like interaction, which involves the creative use of critical thresholds; and deep exploration, which involves exploring the virtually unlimited subtleties of a small control region. The elaboration of these approaches provides an important bridge that connects the concrete descriptions of interaction in musical practices, on the one hand, to the more-abstract mathematical formulation of nonlinear dynamic systems, on the other.