Nahid Yaghoobi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nahid Yaghoobi has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Hadi Malek
Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran
7 shared publications - Mehdi Maghsudi
Technological Virtual Collaboration (TECVICO Corp.), Vancouver, BC, Canada
3 shared publications - Raheleh Hedayati
Department of Nuclear Medicine, Hazrate Rasool Akram Hospital, Iran University of Medical Sciences, Tehran, Iran
3 shared publications Ahmad Bitarafan-Rajabi
Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran
2 shared publications- Ahmad Bitarafan-Rajabi
Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
2 shared publications Hasan Firoozabadi
Rajaie Cardiovascular Medical and Research Center
2 shared publications
Latest Publications
- 5 January 2024
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 31, 101777
Role of CT attenuation correction gated SPECT MPI in prediction of pulmonary hypertension
- 5 January 2024
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 31, 101777
Role of CT attenuation correction gated SPECT MPI in prediction of pulmonary hypertension
- 2 November 2022
- Published by Springer Nature in Nuclear Medicine and Molecular Imaging
- Vol. 57 (3) , 155-158
Diagnosis of Fungal Infection (Candida albicans) After Heart Transplantation in a Pediatric Case with Fever of Unknown Origin: Role of 99mTc-UBI SPECT/CT and 18F-FDG PET/CT
The diagnosis of patients with fever of unknown origin (FUO) in pediatric heart transplantation is a challenging medical problem. The physician should differentiate between rejections, infections, malignancy, adrenal insufficiency, and drug fever. Immunosuppressive therapy in these patients exposes them to a high risk of developing a post-transplantation fungal infection. In this case, we discuss the diagnostic contribution of the 99mTc-UBI scan and 18F-FDG PET scan for diagnosis of fungal infection causing FUO in these patients.
- 2 November 2022
- Published by Springer Nature in Nuclear Medicine and Molecular Imaging
- Vol. 57 (3) , 155-158
Diagnosis of Fungal Infection (Candida albicans) After Heart Transplantation in a Pediatric Case with Fever of Unknown Origin: Role of 99mTc-UBI SPECT/CT and 18F-FDG PET/CT
The diagnosis of patients with fever of unknown origin (FUO) in pediatric heart transplantation is a challenging medical problem. The physician should differentiate between rejections, infections, malignancy, adrenal insufficiency, and drug fever. Immunosuppressive therapy in these patients exposes them to a high risk of developing a post-transplantation fungal infection. In this case, we discuss the diagnostic contribution of the 99mTc-UBI scan and 18F-FDG PET scan for diagnosis of fungal infection causing FUO in these patients.
- 25 June 2022
- Published by Springer Nature in Nuclear Medicine and Molecular Imaging
- Vol. 56 (5) , 256-258
Extensive Venous Tumor Thrombi in a Case of Malignant Melanoma: Role of 18F FDG PET/CT
The 18F-FDG PET/CT imaging is a non-invasive modality for diagnosis and staging of metastatic melanoma. Venous thromboembolism (VTE) is a common complication of cancers, which needs anticoagulant therapy. Tumor thrombosis (TT), on the other hand, is an infrequent complication of solid malignancies that may need aggressive management. Accurate diagnosis of TT and its differentiation from VTE may change patient management and avoid unnecessary anticoagulation treatment. The objective of this case is to introduce a patient with malignant melanoma presenting with extensive venous tumor thrombi with intense FDG uptake.
- 25 June 2022
- Published by Springer Nature in Nuclear Medicine and Molecular Imaging
- Vol. 56 (5) , 256-258
Extensive Venous Tumor Thrombi in a Case of Malignant Melanoma: Role of 18F FDG PET/CT
The 18F-FDG PET/CT imaging is a non-invasive modality for diagnosis and staging of metastatic melanoma. Venous thromboembolism (VTE) is a common complication of cancers, which needs anticoagulant therapy. Tumor thrombosis (TT), on the other hand, is an infrequent complication of solid malignancies that may need aggressive management. Accurate diagnosis of TT and its differentiation from VTE may change patient management and avoid unnecessary anticoagulation treatment. The objective of this case is to introduce a patient with malignant melanoma presenting with extensive venous tumor thrombi with intense FDG uptake.
- 13 May 2021
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 42 (9) , 979-983
Assessment of LV diastolic dysfunction in myocardial perfusion imaging: a correlative study with transthoracic echocardiography
Objective: Myocardial perfusion imaging (MPI) by gated single-photon emission computed tomography (SPECT) is a feasible method in the evaluation of left ventricular perfusion and function. The purpose of this study was to determine the threshold and grading of left ventricular (LV) diastolic dysfunction (LVDD) using gated SPECT MPI. Methods: A total of 149 patients were recruited in the study. All of the patients underwent a standard 2-day stress/rest gated MPI study and transthoracic echocardiography within 2 weeks. The reconstructed rest-only images were analyzed by Cedar-Sinai’s quantitative gated SPECT and the LV diastolic parameters, including peak filling rate (PFR), time to PFR (TTPF) and secondary PFR (PFR2) to PFR ratio were provided and compared to echocardiographic data. Results: 68 (45.6%) and 81 (54.4%) of patients were categorized in LVDD-absent and LVDD-present groups on the basis of LVDD evidence in echocardiography, respectively. receiver-operating-characteristic analysis for PFR and TTPF was performed, resulting in diagnostic sensitivities of 70 and 57% and specificities of 60 and 75% for PFR 160.5 ms, respectively. Applying our previously used thresholds of 208 ms for TTPF and >1 for PFR2/PFR, sensitivities and specificities of 9.9 and 96.6%, 9.9 and 95.6% and 13.8 and 88% were resulted, respectively. Grading of LVDD on the basis of MPI-obtained diastolic parameters showed considerable overlapping data by interquartile range. Conclusion: Gated SPECT MPI can be used as a highly specific means for detection of LV diastolic dysfunction when compared to echocardiography. However, grading of severity of diastolic heart failure appears to be impracticable.
- 13 May 2021
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 42 (9) , 979-983
Assessment of LV diastolic dysfunction in myocardial perfusion imaging: a correlative study with transthoracic echocardiography
Objective: Myocardial perfusion imaging (MPI) by gated single-photon emission computed tomography (SPECT) is a feasible method in the evaluation of left ventricular perfusion and function. The purpose of this study was to determine the threshold and grading of left ventricular (LV) diastolic dysfunction (LVDD) using gated SPECT MPI. Methods: A total of 149 patients were recruited in the study. All of the patients underwent a standard 2-day stress/rest gated MPI study and transthoracic echocardiography within 2 weeks. The reconstructed rest-only images were analyzed by Cedar-Sinai’s quantitative gated SPECT and the LV diastolic parameters, including peak filling rate (PFR), time to PFR (TTPF) and secondary PFR (PFR2) to PFR ratio were provided and compared to echocardiographic data. Results: 68 (45.6%) and 81 (54.4%) of patients were categorized in LVDD-absent and LVDD-present groups on the basis of LVDD evidence in echocardiography, respectively. receiver-operating-characteristic analysis for PFR and TTPF was performed, resulting in diagnostic sensitivities of 70 and 57% and specificities of 60 and 75% for PFR 160.5 ms, respectively. Applying our previously used thresholds of 208 ms for TTPF and >1 for PFR2/PFR, sensitivities and specificities of 9.9 and 96.6%, 9.9 and 95.6% and 13.8 and 88% were resulted, respectively. Grading of LVDD on the basis of MPI-obtained diastolic parameters showed considerable overlapping data by interquartile range. Conclusion: Gated SPECT MPI can be used as a highly specific means for detection of LV diastolic dysfunction when compared to echocardiography. However, grading of severity of diastolic heart failure appears to be impracticable.
- 18 January 2021
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 29 (5) , 2724-2727
Transient multifocal pulmonary uptake of 99mTc-sestamibi in myocardial perfusion imaging: Iatrogenic clot artifact
- 18 January 2021
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 29 (5) , 2724-2727
Transient multifocal pulmonary uptake of 99mTc-sestamibi in myocardial perfusion imaging: Iatrogenic clot artifact
- Open Access
- 20 October 2020
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 29 (3) , 1471-1474
Extra-cardiac multifocal lung uptake of 99mTc-sestamibi in myocardial perfusion imaging: An asymptomatic case with coronavirus infection features
- 20 October 2020
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 29 (3) , 1471-1474
Open AccessExtra-cardiac multifocal lung uptake of 99mTc-sestamibi in myocardial perfusion imaging: An asymptomatic case with coronavirus infection features
- 10 November 2016
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 24 (2) , 534-542
Artifacts in Quantitative analysis of myocardial perfusion SPECT, using Cedars-Sinai QPS Software
- 10 November 2016
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 24 (2) , 534-542
Artifacts in Quantitative analysis of myocardial perfusion SPECT, using Cedars-Sinai QPS Software
- Open Access
- 1 January 2015
- Published by Medknow in Research in Cardiovascular Medicine
- Vol. 4 (4) , 4
The effect of milk, water and lemon juice on various subdiaphragmatic activity-related artifacts in myocardial perfusion imaging
Background: Subdiaphragmatic activity can produce subdiaphragmatic-related artifacts, which can degrade the quality of myocardial perfusion imaging (MPI). Objectives: We examined the impact of drinking milk, water, and lemon juice on different subdiaphragmatic-related artifacts by using 99mTc-sestamibi myocardial single-photon emission computed tomography (SPECT) in order to determine a feasible method for improving the image quality. Patients and Methods: A total of 179 patients (age 58 ± 9.6 years) were enrolled in this study. The patients were randomly divided into five groups. Ten minutes after injection of 740 MBq 99mTc-sestamibi in both pharmacologic stress and rest phases, the individuals in group 1 were given water and milk (125 mL of each); those in group 2 were given lemon juice (250 mL); group 3 was given milk (250 mL); and group 4 was given water (250 mL), whereas no intervention was performed in group 5. The study was double-blind for both subjects and data collectors. MPI was performed for all patients and image quality was controlled by 2 experienced nuclear physicians. Interfering activity was determined visually on reconstructed images and categorized as extracardiac normalization artifact, overlapping of activity, scattering of activity, and ramp filter artifact. Results: There were significant differences in terms of interfering activity among the five groups; group 3 (milk) had significantly lower interfering activity than other groups had, as defined by overlapping of activity (on both stress and rest images), ramp filter artifact (stress images), and scatter artifact (rest images) (P < 0.05). Furthermore, there was a significant difference in the incidence of good-quality images, with no interfering activity in group 3 in the resting state compared with the other groups in the study (P < 0.05). Conclusions: Drinking 250 mL of milk in either the stress phase or the rest phase of imaging diminishes interfering subdiaphragmatic-related artifacts, particularly overlapping of activity in MPI SPECT, resulting in better-quality images. Keywords: Myocardial Perfusion Imaging; Tomography; Emission Computed; Single Photon; Artifacts
- 1 January 2015
- Published by Medknow in Research in Cardiovascular Medicine
- Vol. 4 (4) , 4
Open AccessThe effect of milk, water and lemon juice on various subdiaphragmatic activity-related artifacts in myocardial perfusion imaging
Background: Subdiaphragmatic activity can produce subdiaphragmatic-related artifacts, which can degrade the quality of myocardial perfusion imaging (MPI). Objectives: We examined the impact of drinking milk, water, and lemon juice on different subdiaphragmatic-related artifacts by using 99mTc-sestamibi myocardial single-photon emission computed tomography (SPECT) in order to determine a feasible method for improving the image quality. Patients and Methods: A total of 179 patients (age 58 ± 9.6 years) were enrolled in this study. The patients were randomly divided into five groups. Ten minutes after injection of 740 MBq 99mTc-sestamibi in both pharmacologic stress and rest phases, the individuals in group 1 were given water and milk (125 mL of each); those in group 2 were given lemon juice (250 mL); group 3 was given milk (250 mL); and group 4 was given water (250 mL), whereas no intervention was performed in group 5. The study was double-blind for both subjects and data collectors. MPI was performed for all patients and image quality was controlled by 2 experienced nuclear physicians. Interfering activity was determined visually on reconstructed images and categorized as extracardiac normalization artifact, overlapping of activity, scattering of activity, and ramp filter artifact. Results: There were significant differences in terms of interfering activity among the five groups; group 3 (milk) had significantly lower interfering activity than other groups had, as defined by overlapping of activity (on both stress and rest images), ramp filter artifact (stress images), and scatter artifact (rest images) (P < 0.05). Furthermore, there was a significant difference in the incidence of good-quality images, with no interfering activity in group 3 in the resting state compared with the other groups in the study (P < 0.05). Conclusions: Drinking 250 mL of milk in either the stress phase or the rest phase of imaging diminishes interfering subdiaphragmatic-related artifacts, particularly overlapping of activity in MPI SPECT, resulting in better-quality images. Keywords: Myocardial Perfusion Imaging; Tomography; Emission Computed; Single Photon; Artifacts
- 31 March 2009
- Vol. 12 (1) , 10-2
Correlation of automatic processing method in myocardial perfusion SPET with the interactive method.
Different techniques have been introduced for full automatic processing of myocardial perfusion imaging with single-photon emission tomography. We tried to evaluate the accuracy of one of these commercial automatic processing methods. The study was performed in 300 patients during 18 months. Two post-stress acquisitions in supine and prone positions and one acquisition at rest , were performed for every patient. All images were processed both automatically and interactively and the results were compared to each other. The automatic method matched the interactive method in 95.22% for left ventricle isolation, in 99.54% for excluding extra-cardiac activity and in 98.22% for reorientation of a single projected data. The automatic method was also successful in complete processing of 81.33% sets of stress (supine)-rest and 79.77% sets of stress (prone)-rest images as compared to the interactive method. In conclusion, the fully automated processing method matches the interactive method in complete processing of myocardial perfusion imaging with single-photon emission tomography more than 79.77% and is of equal accuracy to the interactive method in supine and prone-positioned acquisitions.
- 31 March 2009
- Vol. 12 (1) , 10-2
Correlation of automatic processing method in myocardial perfusion SPET with the interactive method.
Different techniques have been introduced for full automatic processing of myocardial perfusion imaging with single-photon emission tomography. We tried to evaluate the accuracy of one of these commercial automatic processing methods. The study was performed in 300 patients during 18 months. Two post-stress acquisitions in supine and prone positions and one acquisition at rest , were performed for every patient. All images were processed both automatically and interactively and the results were compared to each other. The automatic method matched the interactive method in 95.22% for left ventricle isolation, in 99.54% for excluding extra-cardiac activity and in 98.22% for reorientation of a single projected data. The automatic method was also successful in complete processing of 81.33% sets of stress (supine)-rest and 79.77% sets of stress (prone)-rest images as compared to the interactive method. In conclusion, the fully automated processing method matches the interactive method in complete processing of myocardial perfusion imaging with single-photon emission tomography more than 79.77% and is of equal accuracy to the interactive method in supine and prone-positioned acquisitions.