G. Denbeaux
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
G. Denbeaux has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
E. Anderson
Center for X-Ray Optics, Lawrence Berkeley National Laboratory, Berkeley, California, U.S.A.
4 shared publications- Gerd Schneider
Helmholtz Zentrum Berlin für Materialien und Energie GmbH, Wilhelm-Conrad-Röntgen Campus, 12489 Berlin, Germany
4 shared publications A. Pearson
Center for X-Ray Optics, Lawrence Berkeley National Laboratory, One Cyclotron Road, MS 2-400, Berkeley, CA 94720, U.S.A.
3 shared publicationsB. Bates
Center for X-Ray Optics, Lawrence Berkeley National Laboratory, Berkeley, California, U.S.A.
2 shared publicationsE. Zschech
Institut für Röntgenphysik, Georg-August-Universität Göttingen, Geiststrasse 11, 37073 Göttingen, Germany
2 shared publications- M. A. Meyer
Advanced Photon Source, Argonne National Laboratory, Building 432/B0006, 9700 South Cass Avenue, Argonne, IL 60439, U.S.A.
2 shared publications
Latest Publications
- 23 March 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Imaging sub-ns spin dynamics with transmission X-ray microscopy
In this paper, we have studied spin dynamics by X-ray microscopy using the inherent pulsed time structure of 3/sup rd/ generation synchrotrons in a stroboscopic pump-probe experiment. The results obtained with patterned permalloy elements were consistent with micromagnetic simulations.
- 23 March 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Imaging sub-ns spin dynamics with transmission X-ray microscopy
In this paper, we have studied spin dynamics by X-ray microscopy using the inherent pulsed time structure of 3/sup rd/ generation synchrotrons in a stroboscopic pump-probe experiment. The results obtained with patterned permalloy elements were consistent with micromagnetic simulations.
- 1 March 2003
- Published by EDP Sciences in Journal de Physique IV
- Vol. 104, 607-613
High resolution X-ray tomography with applications in biology and materials science
Journal de Physique IV, Journal de Physique Archives représente une mine d informations facile à consulter sur la manière dont la physique a été publiée depuis 1872.
- 1 March 2003
- Published by EDP Sciences in Journal de Physique IV
- Vol. 104, 607-613
High resolution X-ray tomography with applications in biology and materials science
Journal de Physique IV, Journal de Physique Archives représente une mine d informations facile à consulter sur la manière dont la physique a été publiée depuis 1872.
- 1 March 2003
- Published by EDP Sciences in Journal de Physique IV
- Vol. 104, 477-481
X-ray magnetic microscopy for correlations between magnetic domains and crystal structure
Journal de Physique IV, Journal de Physique Archives représente une mine d informations facile à consulter sur la manière dont la physique a été publiée depuis 1872.
- 1 March 2003
- Published by EDP Sciences in Journal de Physique IV
- Vol. 104, 477-481
X-ray magnetic microscopy for correlations between magnetic domains and crystal structure
Journal de Physique IV, Journal de Physique Archives représente une mine d informations facile à consulter sur la manière dont la physique a été publiée depuis 1872.
- 1 November 2002
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
- Vol. 20 (6) , 3089-3094
Electromigration in passivated Cu interconnects studied by transmission x-ray microscopy
Time-resolved x-ray microscopy studies of the electromigration in inlaid Cu line/via structures were performed on focused-ion-beam-prepared cross sections of an advanced interconnect layer system. Multiple x-ray images were recorded at 1.8 keV photon energy while stressing the passivated Cu structures with an applied current. The image sequences show that void formation is a dynamic process, with voids being observed to nucleate and grow within the Cu via and migrate towards the via sidewall. Correlation of the real time x-ray microscopy images with postmortem high voltage transmission electron and scanning electron micrographs indicates that the void nucleation occurs at grain boundaries in the copper, and that the voids migrate along these grain boundaries during electromigration. By taking multiple images at different viewing angles, the three-dimensional arrangement of an interconnect stack with Cu line / via structures was reconstructed. In future studies time-resolved tomography will be used to visualize void dynamics within the volume, thereby identifying pathways for Cu diffusion.
- 1 November 2002
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
- Vol. 20 (6) , 3089-3094
Electromigration in passivated Cu interconnects studied by transmission x-ray microscopy
Time-resolved x-ray microscopy studies of the electromigration in inlaid Cu line/via structures were performed on focused-ion-beam-prepared cross sections of an advanced interconnect layer system. Multiple x-ray images were recorded at 1.8 keV photon energy while stressing the passivated Cu structures with an applied current. The image sequences show that void formation is a dynamic process, with voids being observed to nucleate and grow within the Cu via and migrate towards the via sidewall. Correlation of the real time x-ray microscopy images with postmortem high voltage transmission electron and scanning electron micrographs indicates that the void nucleation occurs at grain boundaries in the copper, and that the voids migrate along these grain boundaries during electromigration. By taking multiple images at different viewing angles, the three-dimensional arrangement of an interconnect stack with Cu line / via structures was reconstructed. In future studies time-resolved tomography will be used to visualize void dynamics within the volume, thereby identifying pathways for Cu diffusion.
- 30 October 2002
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 641 (1) , 461
Soft X-Ray Microscopy and EUV Lithography: An Update on Imaging at 20–40 nm Spatial Resolution
Major advances in both soft x‐ray microscopy, at wavelengths from 0.6 to 4 nm, and EUV lithography, at wavelengths between 13 and 14 nm, are reviewed. In the XRL‐2000 proceedings we reported soft x‐ray microscopy resolved to 25 nm, in static two‐dimensional imaging, with applications to biology, magnetic materials, and various “wet” environmental samples. In this 2002 update we report significant extensions to three‐dimensional tomographic imaging, dynamical studies of magnetic and electronic devices, and static two‐dimensional microscopy poised for extension to below 20 nm spatial resolution. In the XRL‐2000 proceedings we reported EUV lithographic imaging of 50 nm lines/100 nm spaces in static microfield (∼100 μm) exposures. In this 2002 update we report scanned full‐field (25 mm by 32 mm) images at better than 100 nm lines/100 nm spaces, static microfield exposures down to 50 nm lines/50 nm spaces, and isolated lines to 39 nm wide at 0.1 NA. With soon to be available 0.3 NA optics, we expect to print isolated lines, in static micro exposures, at 16–20 nm width in 2003. These results will demonstrate EUV lithography’s ability to meet not only the ITRS Roadmap 45 nm node (26 nm isolated lines in resist) in 2007, but also the 32 nm node (18 nm isolated lines in resist) in 2009, both of which the semiconductor industry is now preparing for.
- 30 October 2002
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 641 (1) , 461
Soft X-Ray Microscopy and EUV Lithography: An Update on Imaging at 20–40 nm Spatial Resolution
Major advances in both soft x‐ray microscopy, at wavelengths from 0.6 to 4 nm, and EUV lithography, at wavelengths between 13 and 14 nm, are reviewed. In the XRL‐2000 proceedings we reported soft x‐ray microscopy resolved to 25 nm, in static two‐dimensional imaging, with applications to biology, magnetic materials, and various “wet” environmental samples. In this 2002 update we report significant extensions to three‐dimensional tomographic imaging, dynamical studies of magnetic and electronic devices, and static two‐dimensional microscopy poised for extension to below 20 nm spatial resolution. In the XRL‐2000 proceedings we reported EUV lithographic imaging of 50 nm lines/100 nm spaces in static microfield (∼100 μm) exposures. In this 2002 update we report scanned full‐field (25 mm by 32 mm) images at better than 100 nm lines/100 nm spaces, static microfield exposures down to 50 nm lines/50 nm spaces, and isolated lines to 39 nm wide at 0.1 NA. With soon to be available 0.3 NA optics, we expect to print isolated lines, in static micro exposures, at 16–20 nm width in 2003. These results will demonstrate EUV lithography’s ability to meet not only the ITRS Roadmap 45 nm node (26 nm isolated lines in resist) in 2007, but also the 32 nm node (18 nm isolated lines in resist) in 2009, both of which the semiconductor industry is now preparing for.