Cristina Zarauz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Cristina Zarauz has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Arelhys Valverde
Department of Prosthodontics, Faculty of Dentistry, Complutense University, Plaza de Ramón y Cajal, 3, 28040, Madrid, Spain
1 shared publicationBassam Hassan
Department of Implant and Prosthetic Dentistry, Academisch Centrum Tandheelkunde Amsterdam, Gustav Mahlerlaan 3004, 1081 LA, Amsterdam, Netherlands
1 shared publication- Francisco Martínez-Rus
Analysis of Techniques, Material and Instruments Applied to Digital Dentistry and CAD/CAM Procedures Research Group University Complutense of Madrid Madrid Spain
1 shared publication - Guillermo Pradíes
Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain
1 shared publication
Latest Publications
- 12 September 2015
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 20 (4) , 799-806
Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions
The aim of this study is to compare the fit of all-ceramic crowns fabricated from conventional silicone impressions with the fit of all-ceramic crowns fabricated from intraoral digital impressions. Twenty patients with 26 posterior teeth with a prosthetic demand were selected for the study. Two crowns (Straumann-Zerion) were made for each preparation. One crown was fabricated from an intraoral digital impression system (IDI group; Cadent-iTero), and the other crown was fabricated from a conventional one-step silicone impression (CI group; Express Penta Putty and Body Light). To replicate the interface between the crown and the preparation, each crown was cemented on its corresponding clinical preparation with ultra-flow silicone (Express Ultra Light Body). Each crown was embedded in resin to stabilize the registered interface, cut in 2-mm-thick slices in a buco-lingual orientation. Internal misfit was measured in microns using stereomicroscopy with a magnification of ×40. Measurements were taken at different landmarks: margin, chamfer angle, axial, crest, and occlusal fosse. After checking for normality, data was analyzed using paired Student’s t test (α = 0.05). Fit values were significantly affected by the impression technique (p = 0.000). Mean internal misfit and mean marginal misfit were 111.40 μm (SD = 54.04)/80.29 μm (SD = 26.24) for the crowns of the IDI group and 173.00 μm (SD = 92.65)/133.51 μm (SD = 48.78) for the CI group. All-ceramic crowns fabricated from intraoral digital impressions with parallel confocal technology demonstrated a clinically acceptable internal and marginal fit as conventional impression. Intraoral digital impressions as initial step to the digital workflow could further improve the marginal adaptation of all ceramic single crowns. http://www.isrctn.com/ISRCTN16111844
- 12 September 2015
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 20 (4) , 799-806
Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions
The aim of this study is to compare the fit of all-ceramic crowns fabricated from conventional silicone impressions with the fit of all-ceramic crowns fabricated from intraoral digital impressions. Twenty patients with 26 posterior teeth with a prosthetic demand were selected for the study. Two crowns (Straumann-Zerion) were made for each preparation. One crown was fabricated from an intraoral digital impression system (IDI group; Cadent-iTero), and the other crown was fabricated from a conventional one-step silicone impression (CI group; Express Penta Putty and Body Light). To replicate the interface between the crown and the preparation, each crown was cemented on its corresponding clinical preparation with ultra-flow silicone (Express Ultra Light Body). Each crown was embedded in resin to stabilize the registered interface, cut in 2-mm-thick slices in a buco-lingual orientation. Internal misfit was measured in microns using stereomicroscopy with a magnification of ×40. Measurements were taken at different landmarks: margin, chamfer angle, axial, crest, and occlusal fosse. After checking for normality, data was analyzed using paired Student’s t test (α = 0.05). Fit values were significantly affected by the impression technique (p = 0.000). Mean internal misfit and mean marginal misfit were 111.40 μm (SD = 54.04)/80.29 μm (SD = 26.24) for the crowns of the IDI group and 173.00 μm (SD = 92.65)/133.51 μm (SD = 48.78) for the CI group. All-ceramic crowns fabricated from intraoral digital impressions with parallel confocal technology demonstrated a clinically acceptable internal and marginal fit as conventional impression. Intraoral digital impressions as initial step to the digital workflow could further improve the marginal adaptation of all ceramic single crowns. http://www.isrctn.com/ISRCTN16111844