  • Filtering of ECG signals distorted by magnetic field gradients during MRI using non-linear filters and higher-order statistics

    by Marcus Schmidt, Johannes W. Krug, Michael N. Rosenheimer, Georg Rose

    The electrocardiogram (ECG) is the state-of-the-art signal for patient monitoring and gating in cardiovascular magnetic resonance (CMR) imaging applications. However, ECG signals are severely distorted during MRI scans due to the effects of static magnetic fields, radio frequency pulses and fast-switching gradient magnetic fields. Gradient-induced artifacts that cause high frequency peaks in the ECG signal especially hamper a correct and reliable QRS detection. To cope with this problem, a new median-based real-time gradient filter (M1) approach was developed. To improve the filter results, a preprocessing step based on higher-order statistics (M2) was added to this. For the evaluation of the filtering techniques, ECG signals were acquired in a 3T MRI scanner during different MR sequences. A qualitative comparison was made using the mean square error as well as the signal power before and after filtering and the results of the QRS detection. Here, reliable results were achieved (detection error rate [DER] M1: 0.23%, DER M2: 0.74%). It was shown that the two developed techniques allowed a reliable suppression of the gradient artifacts in real time.


  • ECG derived respiration: comparison of time-domain approaches and application to altered breathing patterns of patients with schizophrenia

    by Marcus Schmidt, Andy Schumann, Jonas Mueller, Karl-Juergen Baer, Georg Rose

    In life-threatening diseases and in several clinical interventions, monitoring of vital parameters is essential to guarantee the safety of patients. Besides monitoring the electrocardiogram (ECG), it is helpful to assess respiratory activity. If the respiration signal itself is not recorded, it can be extracted from the ECG (i.e. ECG derived respiration, EDR). In the present paper, we compared six EDR approaches, namely RS-decline quantified by central moments, respiratory sinus arrhythmia (RSA), R-wave amplitude, QRS area, RS-distance and maximum RS-slope. In order to evaluate the performance of each approach, we applied each method to a database of ECGs and reference respiration signals of 41 healthy subjects. All considered methods revealed relatively small absolute mean errors of the breathing rate (BR) at rest (0.75–1.3 Bpm). The method based on higher order central moments revealed a minimum mean absolute error of 0.75 Bpm (4.40%) and a maximum correlation and concordance with the reference BR ( r p = 0.97, r c = 0.97). Using this technique, we analyzed changes of respiration in patients suffering from acute schizophrenia. An increased respiration rate of about 4 Bpm was found. Additionally, alteration of respiratory ratio and reduced respiratory sinus arrhythmia was demonstrated. We conclude that a precise dynamic monitoring of breathing and the investigation of changes in breathing patterns is possible without recording respiration per se.


  • Open Access

    Determining cardiac vagal threshold from short term heart rate complexity

    by Rami Abou Hamdan, Andy Schumann, Marco Herbsleb, Marcus Schmidt, Georg Rose, Karl-Jürgen Bär, Holger Gabriel

    Evaluating individual aerobic exercise capacity is fundamental in sports and exercise medicine but associated with organizational and instrumental effort. Here, we extract an index related to common performance markers, the aerobic and anaerobic thresholds enabling the estimation of exercise capacity from a conventional sports watch supporting beatwise heart rate tracking. Therefore, cardiac vagal threshold (CVT) was determined in 19 male subjects performing an incremental maximum exercise test. CVT varied around the anaerobic threshold AnT with mean deviation of 7.9 ± 17.7 W. A high correspondence of the two thresholds was indicated by Bland-Altman plots with limits of agreement −27.5 W and 43.4 W. Additionally, CVT was strongly correlated AnT (rp = 0.86, p < 0.001) and reproduced this marker well (rc = 0.81). We conclude, that cardiac vagal threshold derived from compression entropy time course can be useful to assess physical fitness in an uncomplicated way


  • Open Access

    An automatic systolic peak detector of blood pressure waveforms using 4th order cumulants

    by Marcus Schmidt, Andy Schumann, Karl-Jürgen Bär, Georg Rose

    The arterial blood pressure (ABP) holds a lot of information about the cardiovascular system. To analyse the ABP signal, at first the pulse wave has to be detected correctly. Due to influences, e.g. of noise, an accurate beat detection is a challenging task. In this work, a novel real-time ABP detector based on higher-order statistics is presented. The method uses the 4th order cumulants for ABP-peak detection. To evaluate this detector, the Fantasia database freely available at physionet was used. In this database, 142,936 systolic peaks were available to check the efficiency of the beat detector. A sensitivity of 99.91% and a positive predictive value of 99.50% were achieved with the novel method.


  • Open Access

    Reducing of gradient induced artifacts on the ECG signal during MRI examinations using Wilcoxon filter

    by Marcus Schmidt, Johannes W. Krug, Georg Rose

    The electrocardiogramm (ECG) is the state-of-the-art signal for gating in cardiovascular magnetic resonance imaging and patient monitoring. Using the ECG for gating and monitoring during the magnetic resonance imaging examination is a high challenging task due to the superimposition of the magnetohydrodynamic effect, radio-frequency (RF) pulses and fast switching gradient magnetic fields. The gradient induced artifacts hamper the correct QRS detection which is needed for correct gating and heart rate calculation and ECG displaying for patient monitoring. To suppress the gradient artifacts from the ECG signal acquired during MRI, a technique based on the Wilcoxon filter was developed. It was evaluated using ECG signals of 14 different subjects acquired in a 3 T MRI scanner. It could be shown reliable results for reducing gradient induced artifacts in the ECG signal in real-time


  • Open Access

    Real-time QRS detection using integrated variance for ECG gated cardiac MRI

    by Marcus Schmidt, Johannes W. Krug, Georg Rose

    During magnetic resonance imaging (MRI), a patient’s vital signs are required for different purposes. In cardiac MRI (CMR), an electrocardiogram (ECG) of the patient is required for triggering the image acquisition process. However, a reliable QRS detection of an ECG signal acquired inside an MRI scanner is a challenging task due to the magnetohydrodynamic (MHD) effect which interferes with the ECG. The aim of this work was to develop a reliable QRS detector usable inside the MRI which also fulfills the standards for medical devices (IEC 60601-2-27). Therefore, a novel real-time QRS detector based on integrated variance measurements is presented. The algorithm was trained on ANSI/AAMI EC13 test waveforms and was then applied to two databases with 12-lead ECG signals recorded inside and outside an MRI scanner. Reliable results for both databases were achieved for the ECG signals recorded inside (DBMRI: sensitivity Se = 99.94%, positive predictive value +P = 99.84%) and outside (DBInCarT: Se = 99.29%, +P = 99.72%) the MRI. Due to the accurate R-peak detection in real-time this can be used for monitoring and triggering in MRI exams.


  • Open Access

    Estimation of a respiratory signal from a single-lead ECG using the 4th order central moments

    by Marcus Schmidt, Johannes W Krug, Andy Schumann, Karl-Jürgen Bär, Georg Rose

    For a variety of clinical applications like magnetic resonance imaging (MRI) the monitoring of vital signs is a common standard in clinical daily routine. Besides the electrocardiogram (ECG), the respiratory activity is an important vital parameter and might reveal pathological changes. Thoracic movement and the resulting impedance change between ECG electrodes enable the estimation of the respiratory signal from the ECG. This ECG-derived respiration (EDR) can be used to calculate the breathing rate without the need for additional devices or monitoring modules. In this paper a new method is presented to estimate the respiratory signal from a single-lead ECG. The 4th order central moments was used to estimate the EDR signal exploiting the change of the R-wave slopes induced by respiration. This method was compared with two approaches by analyzing the Fantasia database from www.physionet.org. Furthermore, the ECG signals of 24 healthy subjects placed in an 3 T MR-scanner were acquired.